C. Smorra

Orders of Magnitude Improved Cyclotron-Mode Cooling for Non-Destructive Spin Quantum Transition Spectroscopy with Single Trapped Antiprotons

B. M. Latacz [1,2], M. Fleck [1,3,2,4], J. I. Jaeger, G. Umbrazunas [1,5], B. P. Arndt [1,4,6], S. R. Erlewein [1,4], E. J. Wursten [1], J. A. Devlin [1,2], P. Micke [1,2,4], F. Abbass [7], D. Schweitzer [7], M. Wiesinger [4], C. Will [4], H. Yildiz [7], K. Blaum [4], Y. Matsuda [3], A. Mooser [4], C. Ospelkaus [8,9], A. Soter [5], W. Quint [6], J. Walz [7,10], Y. Yamazaki [1], C. Smorra [1,7], S. Ulmer [1,11]

Abstract

We demonstrate efficient sub-thermal cooling of the modified cyclotron mode of a single trapped antiproton and reach particle temperatures $T_+=E_+/k_\text{B}$ below $200\,$mK in preparation times shorter than $500\,$s. This corresponds to the fastest resistive single-particle cyclotron cooling to sub-thermal temperatures ever demonstrated. By cooling trapped particles to such low energies, we demonstrate the detection of antiproton spin transitions with an error-rate $<0.000025$, more than three orders of magnitude better than in previous best experiments. This method will have enormous impact on multi-Penning-trap experiments that measure magnetic moments with single nuclear spins for tests of matter/antimatter symmetry, high-precision mass-spectrometry, and measurements of electron $g$-factors bound to highly-charged ions that test quantum electrodynamics.

BASE-STEP: A transportable antiproton reservoir for fundamental interaction studies

C. Smorra [1,2], F. Abbass [1], M. Bohman [2,3], Y. Dutheil [4], A. Hobl [5], D. Popper [1], B. Arndt [2,3,6], B. B. Bauer [1,2], J. A. Devlin [2,4], S. Erlewein [2,3,4], M. Fleck [2,3,4], J. I. Jäger, B. M. Latacz [2,4], P. Micke [3,4], M. Schiffelholz [7,8], G. Umbrazunas [2,9], M. Wiesinger [3], C. Will [3], E. Wursten [2,4], H. Yildiz [1], K. Blaum [3], Y. Matsuda [10], A. Mooser [3], C. Ospelkaus [7,8], W. Quint [6], A. Soter [9], J. Walz [1,11], Y. Yamazaki [2], S. Ulmer [2,12]

Abstract

Currently, the only worldwide source of low-energy antiprotons is the AD/ELENA facility located at CERN. To date, all precision measurements on single antiprotons have been conducted at this facility and provide stringent tests of the fundamental interactions and their symmetries. However, the magnetic field fluctuations from the facility operation limit the precision of upcoming measurements. To overcome this limitation, we have designed the transportable antiproton trap system BASE-STEP to relocate antiprotons to laboratories with a calm magnetic environment. We anticipate that the transportable antiproton trap will facilitate enhanced tests of CPT invariance with antiprotons, and provide new experimental possibilities of using transported antiprotons and other accelerator-produced exotic ions. We present here the technical design of the transportable trap system. This includes the transportable superconducting magnet, the cryogenic inlay consisting of the trap stack and the detection systems, and the differential pumping section to suppress the residual gas flow into the cryogenic trap chamber.

Sympathetic cooling schemes for separately trapped ions coupled via image currents

C. Will [1], M. Bohman [1,2], T. Driscoll [3], M. Wiesinger [1,2], F. Abbass [4], M. J. Borchert [2,5,6], J. A. Devlin [2,7], S. Erlewein [2,7], M. Fleck [2,8], B. Latacz [2], R. Moller [4], A. Mooser [1], D. Popper [4], E. Wursten [1,2,7], K. Blaum [1], Y. Matsuda [8], C. Ospelkaus [5,6], W. Quint [9], J. Walz [4,10], C. Smorra [2,4], S. Ulmer [2]

Abstract

Cooling of particles to mK-temperatures is essential for a variety of experiments with trapped charged particles. However, many species of interest lack suitable electronic transitions for direct laser cooling. We study theoretically the remote sympathetic cooling of a single proton with laser-cooled $^9$Be$^+$ in a double-Penning-trap system. We investigate three different cooling schemes and find, based on analytical calculations and numerical simulations, that two of them are capable of achieving proton temperatures of about 10 mK with cooling times on the order of 10 s. In contrast, established methods such as feedback-enhanced resistive cooling with image-current detectors are limited to about 1 K in 100 s. Since the studied techniques are applicable to any trapped charged particle and allow spatial separation between the target ion and the cooling species, they enable a variety of precision measurements based on trapped charged particles to be performed at improved sampling rates and with reduced systematic uncertainties.

Sympathetic cooling of a trapped proton mediated by an LC circuit

M. Bohman [1], V. Grunhofer, C. Smorra, M. Wiesinger [1], C. Will [1], M. J. Borchert [4], J. A. Devlin, S. Erlewein, M. Fleck, S. Gavranovic, J. Harrington [1], B. Latacz, A. Mooser [1], D. Popper, E. Wursten, K. Blaum [1], Y. Matsuda, C. Ospelkaus [4], W. Quint, J. Walz, S. Ulmer

Abstract

Efficient cooling of trapped charged particles is essential to many fundamental physics experiments, to high-precision metrology, and to quantum technology. Until now, sympathetic cooling has required close-range Coulomb interactions, but there has been a sustained desire to bring laser-cooling techniques to particles in macroscopically separated traps, extending quantum control techniques to previously inaccessible particles such as highly charged ions, molecular ions and antimatter. Here we demonstrate sympathetic cooling of a single proton using laser-cooled Be+ ions in spatially separated Penning traps. The traps are connected by a superconducting LC circuit that enables energy exchange over a distance of 9 cm. We also demonstrate the cooling of a resonant mode of a macroscopic LC circuit with laser-cooled ions and sympathetic cooling of an individually trapped proton, reaching temperatures far below the environmental temperature. Notably, as this technique uses only image-current interactions, it can be easily applied to an experiment with antiprotons, facilitating improved precision in matter-antimatter comparisons and dark matter searches.

Measurement of ultra-low heating rates of a single antiproton in a cryogenic Penning trap

M. J. Borchert [1,2], P. E. Blessing [1,3], J. A. Devlin [1], J. A. Harrington [1,4], T. Higuchi [1,5], J. Morgner [1,2], C. Smorra [1], E. Wursten [1,7], M. Bohman [1,4], M. Wiesinger [1,4], A. Mooser [1], K. Blaum [4], Y. Matsuda [5], C. Ospelkaus [2,8], W. Quint [3,9], J. Walz [6,10], Y. Yamazaki [11], S. Ulmer [1]

Abstract

We report on the first detailed study of motional heating in a cryogenic Penning trap using a single antiproton. Employing the continuous Stern-Gerlach effect we observe cyclotron quantum transition rates of 6(1) quanta/h and an electric field noise spectral density below $7.5(3.4)\times 10^{-20}\,\text{V}^{2}\text{m}^{-2} \text{Hz}^{-1}$, which corresponds to a scaled noise spectral density below $8.8(4.0)\times 10^{-12}\,\text{V}^{2}\text{m}^{-2}$, results which are more than two orders of magnitude smaller than those reported by other ion trap experiments.

Sympathetic Cooling of Protons and Antiprotons with a Common Endcap Penning Trap

M. Bohman, A. Mooser, G. Schneider, N Schön, M. Wiesinger, J. Harrington, T. Higuchi, H. Nagahama, S. Sellner, C. Smorra, K. Blaum, Y. Matsuda, W. Quint [1], J. Walz [1], S. Ulmer [1]

Abstract

We present an experiment to sympathetically cool protons and antiprotons in a Penning trap by resonantly coupling the particles to laser cooled beryllium ions using a common endcap technique. Our analysis shows that preparation of (anti)protons at mK temperatures on timescales of tens of seconds is feasible. Successful implementation of the technique will have immediate and significant impact on high-precision comparisons of the fundamental properties of protons and antiprotons. This in turn will provide some of the most stringent tests of the fundamental symmetries of the Standard Model.

A novel ion cooling trap for multi-reflection time-of-flight mass spectrograph

Y. Ito, P. Schury, M. Wada, S. Naimi, C. Smorra, T. Sonoda, H. Mita, A. Takamine, K. Okada, A. Ozawa, H. Wollnik [1]

Abstract

A radiofrequency quadrupole ion trap system for use with a multi-reflection time-of-flight mass spectrograph (MRTOF) for short-lived nuclei has been developed. The trap system consists of two different parts, an asymmetric taper trap and a flat trap. The ions are cooled to a sufficient small bunch for precise mass measurement with MRTOF in only 2 ms cooling time in the flat trap, then orthogonally ejected to the MRTOF for mass analysis. A trapping efficiency of ~27% for 23Na+ and ~5.1% for 7Li+ has been achieved.

Position-sensitive ion detection in precision Penning trap mass spectrometry

G. Eitel, M. Block, A. Czasch, M. Dworschak, S. George, O. Jagutzki, J. Ketelaer, J. Ketter, Sz. Nagy, D. Rodriguez, C. Smorra [1], K. Blaum [1]

Abstract

A commercial, position-sensitive ion detector was used for the first time for the time-of-flight ion-cyclotron resonance detection technique in Penning trap mass spectrometry. In this work, the characteristics of the detector and its implementation in a Penning trap mass spectrometer will be presented. In addition, simulations and experimental studies concerning the observation of ions ejected from a Penning trap are described. This will allow for a precise monitoring of the state of ion motion in the trap.

TRIGA-SPEC: A setup for mass spectrometry and laser spectroscopy at the research reactor TRIGA Mainz

J. Ketelaer, J. Krämer, D. Beck, K. Blaum, M. Block, K. Eberhardt, G. Eitel, R. Ferrer, C. Geppert, S. George, F. Herfurth, J. Ketter, Sz. Nagy, D. Neidherr, R. Neugart [1], W. Nörtershäuser, J. Repp [1], C. Smorra [1], N. Trautmann [1], C. Weber [1]

Abstract

The research reactor TRIGA Mainz is an ideal facility to provide neutron-rich nuclides with production rates sufficiently large for mass spectrometric and laser spectroscopic studies. Within the TRIGA-SPEC project, a Penning trap as well as a beam line for collinear laser spectroscopy are being installed. Several new developments will ensure high sensitivity of the trap setup enabling mass measurements even on a single ion. Besides neutron-rich fission products produced in the reactor, also heavy nuclides such as 235-U or 252-Cf can be investigated for the first time with an off-line ion source. The data provided by the mass measurements will be of interest for astrophysical calculations on the rapid neutron-capture process as well as for tests of mass models in the heavy-mass region. The laser spectroscopic measurements will yield model-independent information on nuclear ground-state properties such as nuclear moments and charge radii of neutron-rich nuclei of refractory elements far from stability. This publication describes the experimental setup as well as its present status.