E. Silver

A Cryogen-Free Electron Beam Ion Trap for Astrophysically Relevant Spectroscopic Studies

A. C. Gall, A. Foster [1], Y. Yang [2], E. Takacs [2], N. S. Brickhouse [1], E. Silver [1], R. K. Smith [1]

Abstract

The detailed design and operation of the Smithsonian Astrophysical Observatory's EBIT are described for the first time, including recent design upgrades that have led to improved system stability and greater user control, increasing the scope of possible experiments. Measurements of emission from highly charged Ar were taken to determine the spatial distribution of the ion cloud and electron beam. An optical setup consisting of two lenses, a narrow band filter, and a CCD camera was used to image visible light, while an X-ray pinhole and CCD camera were used to image X-rays. Measurements were used to estimate an effective electron density of 1.77 x 10$^{10}$ cm$^{-3}$. Additionally, observations of X-ray emission from background EBIT gases were measured with a Silicon Lithium detector. Measurements indicate the presence of Ba and Si, which are both easily removed by dumping the trap every 2 s or less.

Fe XVII X-ray Line Ratios for Accurate Astrophysical Plasma Diagnostics

J. D. Gillaspy [1], T. Lin [2], L. Tedesco [1], J. N. Tan [1], J. M. Pomeroy [1], J. M. Laming [3], N. Brickhouse [2], G. -X. Chen [2], E. Silver [2]

Abstract

New laboratory measurements using an Electron Beam Ion Trap (EBIT) and an x-ray microcalorimeter are presented for the n=3 to n=2 Fe XVII emission lines in the 15 Å to 17 Å range, along with new theoretical predictions for a variety of electron energy distributions. This work improves upon our earlier work on these lines by providing measurements at more electron impact energies (seven values from 846 to 1185 eV), performing an in situ determination of the x-ray window transmission, taking steps to minimize the ion impurity concentrations, correcting the electron energies for space charge shifts, and estimating the residual electron energy uncertainties. The results for the 3C/3D and 3s/3C line ratios are generally in agreement with the closest theory to within 10%, and in agreement with previous measurements from an independent group to within 20%. Better consistency between the two experimental groups is obtained at the lowest electron energies by using theory to interpolate, taking into account the significantly different electron energy distributions. Evidence for resonance collision effects in the spectra is discussed. Renormalized values for the absolute cross sections of the 3C and 3D lines are obtained by combining previously published results, and shown to be in agreement with the predictions of converged R-matrix theory. This work establishes consistency between results from independent laboratories and improves the reliability of these lines for astrophysical diagnostics. Factors that should be taken into account for accurate diagnostics are discussed, including electron energy distribution, polarization, absorption/scattering, and line blends.