Ingo Roth

Local robust shadows on a trapped ion computer -- a case study

Jadwiga Wilkens, Milena Guevara-Bertsch, Marwa Marso, Mederika Zangerl, Florian Girtler, Albert Frisch, Juris Ulmanis, Ingo Roth, Richard Kueng

Abstract

We experimentally demonstrate local robust shadows on a trapped-ion quantum computing system, a protocol developed to counteract measurement errors. We alternate between a calibration stage and the shadow estimation stage and also introduce Pauli-X-twirling before measurements in both stages to symmetrize error rates. We then demonstrate the protocol on a trapped-ion quantum computer with artificially shortened measurement pulse duration. This yields faster experiments at the cost of increased error rates which are subsequently mitigated by the robust shadow protocol. We benchmark this approach on three exemplary quantum states: a local Haar random state, as well as standard and Pauli-correlation-encoded QAOA states. In all three cases, the local robust shadow protocol succeeds at mitigating the increased error rates hailing from shorter measurement pulse durations.

Blind calibration of a quantum computer

Liam M. Jeanette [1,2], Jadwiga Wilkens [3], Ingo Roth [4], Anton Than [1], Alaina M. Green [1], Dominik Hangleiter [5,6,7], Norbert M. Linke [2,1]

Abstract

The calibration of quantum measurements is limited by the ability to accurately prepare quantum states under unknown device errors. We develop an accurate calibration protocol for the measurement apparatus of a quantum computer that is `blind' to the state preparation. Blind calibration quantifies and corrects measurement errors from simple tomographic data on a noisy quantum state. Importantly, it calibrates multiple error mechanisms in a single experiment, eliminating the need for bespoke, separate calibration experiments. Using a trapped-ion quantum computer, we systematically demonstrate the accuracy of the method. We use blind calibration to estimate the native calibration parameters of the experimental system. The recovered calibrations are consistent with directly measured values and perform similarly in predicting the state properties.

Semi-device-dependent blind quantum tomography

Ingo Roth [1,2], Jadwiga Wilkens [1,2], Dominik Hangleiter [3,2], Jens Eisert [2,4]

Abstract

Extracting tomographic information about quantum states is a crucial task in the quest towards devising high-precision quantum devices. Current schemes typically require measurement devices for tomography that are a priori calibrated to high precision. Ironically, the accuracy of the measurement calibration is fundamentally limited by the accuracy of state preparation, establishing a vicious cycle. Here, we prove that this cycle can be broken and the dependence on the measurement device's calibration significantly relaxed. We show that exploiting the natural low-rank structure of quantum states of interest suffices to arrive at a highly scalable `blind' tomography scheme with a classically efficient post-processing algorithm. We further improve the efficiency of our scheme by making use of the sparse structure of the calibrations. This is achieved by relaxing the blind quantum tomography problem to the de-mixing of a sparse sum of low-rank matrices. We prove that the proposed algorithm recovers a low-rank quantum state and the calibration provided that the measurement model exhibits a restricted isometry property. For generic measurements, we show that it requires a close-to-optimal number of measurement settings. Complementing these conceptual and mathematical insights, we numerically demonstrate that robust blind quantum tomography is possible in a practical setting inspired by an implementation of trapped ions.