M. Filzinger

High-Resolution Spectroscopy of $^{173}$Yb$^{+}$ Ions

J. Jiang [1], A. V. Viatkina [1,2], Saaswath JK [1], M. Steinel [1], M. Filzinger [1], E. Peik [1], S. G. Porsev [3], M. S. Safronova [3], A. Surzyhkov [1,2,4], N. Huntemann [1]

Abstract

Compared to other stable isotopes of $\rm{Yb}^+$, $^{173}\rm{Yb}^+$ has a richer hyperfine structure, which leads to more favorable clock transitions, spectroscopic techniques for probing new physics, and more sophisticated quantum computing architectures. However, to date, its electronic spectrum remains poorly characterized. Here, we report on efficient laser cooling, state preparation, and detection of a single trapped $^{173}\rm{Yb}^+$ ion. The previously unobserved $^2\!S_{1/2} \rightarrow {}^2\!D_{3/2}$ electric quadrupole transition at 436 nm is coherently excited, and the isotope shift between $^{171}\rm{Yb}^+$ and $^{173}\rm{Yb}^+$ on this transition is determined with an uncertainty of 1.4 Hz. Using microwave spectroscopy, we resolve the hyperfine structure (HFS) of the ${}^2\!D_{3/2}$ state with a relative uncertainty below $10^{-8}$. From the HFS measurement data, we infer for ${}^{173}$Yb a nuclear magnetic octupole moment $Ω= -0.062(8)\,({\rm b} \times μ_N)$ with uncertainty reduced by more than 2 orders of magnitude compared to previous studies. The data also allow us to determine hyperfine anomalies for the ${}^2\!S_{1/2}$ and ${}^2\!D_{3/2}$ states.

$^{115}$In$^+$-$^{172}$Yb$^+$ Coulomb crystal clock with $2.5\times10^{-18}$ systematic uncertainty

H. N. Hausser [1], J. Keller [1], T. Nordmann [1], N. M. Bhatt [1], J. Kiethe [1], H. Liu [1], I. M. Richter [1], M. von Boehn [1], J. Rahm [1], S. Weyers [1], E. Benkler [1], B. Lipphardt [1], S. Doerscher, K. Stahl [1], J. Klose [1], C. Lisdat [1], M. Filzinger [1], N. Huntemann [1], E. Peik [1,2,3], T. E. Mehlstäubler

Abstract

We present a scalable mixed-species Coulomb crystal clock based on the $^1S_0$ $\leftrightarrow$ $^3P_0$ transition in $^{115}$In$^+$. $^{172}$Yb$^+$ ions are co-trapped and used for sympathetic cooling. Reproducible interrogation conditions for mixed-species Coulomb crystals are ensured by a conditional preparation sequence with permutation control. We demonstrate clock operation with a 1In$^+$-3Yb$^+$ crystal, achieving a relative systematic uncertainty of $2.5\times10^{-18}$ and a relative frequency instability of $1.6\times10^{-15}/\sqrt{τ/1\;\mathrm{s}}$. We report on absolute frequency measurements with an uncertainty of $1.3\times10^{-16}$ and optical frequency comparisons with clocks based on $^{171}$Yb$^+$ (E3) and $^{87}$Sr. With a fractional uncertainty of $4.4\times10^{-18}$, the former is - to our knowledge - the most accurate frequency ratio value reported to date. For the $^{115}$In$^+$/$^{87}$Sr ratio, we improve upon the best previous measurement by more than an order of magnitude. We also demonstrate operation with four $^{115}$In$^+$ clock ions, which reduces the instability to $9.2\times10^{-16}/\sqrt{τ/1\;\mathrm{s}}$.