P. Gill

Compact laser system for a laser-cooled ytterbium ion microwave frequency standard

S. Mulholland [1,2], H. A. Klein [1], G. P. Barwood, S. Donnellan [1], P. B. R. Nisbet-Jones, G. Huang [1], G. Walsh [1,2], P. E. G. Baird, P. Gill [1,2]

Abstract

The development of a transportable microwave frequency standard based on the ground-state transition of $^{171}\mathrm{Yb^{+}}$ at ~12.6 GHz requires a compact laser system for cooling the ions, clearing out of long-lived states and also for photoionisation. In this paper, we describe the development of a suitable compact laser system based on a 6U height rack-mounted arrangement with overall dimensions $260 \times 194 \times 335$ mm. Laser outputs at 369 nm (for cooling), 399 nm (photoionisation), 935 nm (repumping) and 760 nm (state clearout) are combined in a fiber arrangement for delivery to our linear ion trap and we demonstrate this system by cooling of $^{171}\mathrm{Yb^{+}}$ ions. Additionally, we demonstrate that the lasers at 935 nm and 760 nm are close in frequency to water vapor and oxygen absorption lines respectively; specifically, at 760 nm, we show that one $^{171}\mathrm{Yb^{+}}$ transition is within the pressure broadened profile of an oxygen line. These molecular transitions form convenient wavelength references for the stabilization of lasers for a $^{171}\mathrm{Yb^{+}}$ frequency standard.

Laser-cooled ytterbium ion frequency standard

S. Mulholland [1,2], H. A. Klein [1], G. P. Barwood, S. Donnellan [1], D. Gentle [1], G. Huang [1], G. Walsh [1,2], P. E. G. Baird, P. Gill [1,2]

Abstract

We report on the development of a trapped-ion, microwave frequency standard based on the 12.6 GHz hyperfine transition in laser-cooled ytterbium-171 ions. The entire system fits into a 6U 19-inch rack unit ($51\times49\times28$ cm) and comprises laser, electronics, and physics package subsystems. The performance of this development system is evaluated; the fractional frequency instability was measured to be $3.6\times10^{-12}/\surdτ$ for averaging times between 30 s and 1500 s.

A Single-Ion Trap with Minimized Ion-Environment Interactions

P. B. R. Nisbet-Jones, S. A. King, J. M. Jones, R. M. Godun, C. F. A. Baynham, K. Bongs, M. Doležal, P. Balling, P. Gill

Abstract

We present a new single-ion endcap trap for high precision spectroscopy that has been designed to minimize ion-environment interactions. We describe the design in detail and then characterize the working trap using a single trapped 171 Yb ion. Excess micromotion has been eliminated to the resolution of the detection method and the trap exhibits an anomalous phonon heating rate of d<n> /dt = 24 +30/-24 per second. The thermal properties of the trap structure have also been measured with an effective temperature rise at the ion's position of 0.14 +/- 0.14 K. The small perturbations to the ion caused by this trap make it suitable to be used for an optical frequency standard with fractional uncertainties below the 10^-18 level.

Optical atomic clocks

N. Poli [1], C. W. Oates [2], P. Gill [3], G. M. Tino [1]

Abstract

In the last ten years extraordinary results in time and frequency metrology have been demonstrated. Frequency-stabilization techniques for continuous-wave lasers and femto-second optical frequency combs have enabled a rapid development of frequency standards based on optical transitions in ultra-cold neutral atoms and trapped ions. As a result, today's best performing atomic clocks tick at an optical rate and allow scientists to perform high-resolution measurements with a precision approaching a few parts in $10^{18}$. This paper reviews the history and the state of the art in optical-clock research and addresses the implementation of optical clocks in a possible future redefinition of the SI second as well as in tests of fundamental physics.