T. Schneider

Frequency comparisons and absolute frequency measurements of 171Yb+ single-ion optical frequency standards

E. Peik, B. Lipphardt, H. Schnatz, T. Schneider, Chr. Tamm, S. G. Karshenboim [2,3]

Abstract

We describe experiments with an optical frequency standard based on a laser cooled $^{171}$Yb$^+$ ion confined in a radiofrequency Paul trap. The electric-quadrupole transition from the $^2S_{1/2}(F=0)$ ground state to the $^2D_{3/2}(F=2)$ state at the wavelength of 436 nm is used as the reference transition. In order to compare two $^{171}$Yb$^+$ standards, separate frequency servo systems are employed to stabilize two probe laser frequencies to the reference transition line centers of two independently stored ions. The experimental results indicate a relative instability (Allan standard deviation) of the optical frequency difference between the two systems of $σ_y(1000 {\rm s})=5\cdot 10^{-16}$ only, so that shifts in the sub-hertz range can be resolved. Shifts of several hertz are observed if a stationary electric field gradient is superimposed on the radiofrequency trap field. The absolute optical transition frequency of Yb$^+$ at 688 THz was measured with a cesium atomic clock at two times separated by 2.8 years. A temporal variation of this frequency can be excluded within a $1σ$ relative uncertainty of $4.4\cdot 10^{-15}$ yr$^{-1}$. Combined with recently published values for the constancy of other transition frequencies this measurement provides a limit on the present variability of the fine structure constant $α$ at the level of $2.0\cdot 10^{-15}$ yr$^{-1}$.

Comparison of two single-ion optical frequency standards at the sub-Hertz level

Chr. Tamm [1], T. Schneider [1], E. Peik [1]

Abstract

We describe experimental investigations on an optical frequency standard based on a laser cooled 171Yb+ ion confined in a radiofrequency Paul trap. The electric-quadrupole transition from the 2S1/2(F=0) ground state to the 2D3/2(F=2) state at the wavelength of 436 nm is used as the reference transition. The reference transition is probed by a frequency-doubled, frequency-stabilized diode laser and is resolved with a Fourier-limited full halfwidth of approximately 30 Hz. In order to compare two 171Yb+ standards, separate frequency shift and servo systems are employed to stabilise the probe frequency to the reference transition line centers of two independently stored 171Yb+ ions. The present experimental results indicate a relative instability (Allan standard deviation)of the optical frequency difference between the two systems of sigma_y(1000 s)=1.0E-15 and a mean frequency difference of 0.2 Hz. Shifts in the range of several Hertz are observed in the frequency difference if a stationary electric field gradient is superimposed on the radiofrequency trap field. This measurement permits a first experimental estimate of the electric quadrupole moment of the 2D3/2 state of Yb+.