U. Hager

Mass Measurements and Implications for the Energy of the High-Spin Isomer in 94Ag

A. Kankainen [1], V. -V. Elomaa [1], L. Batist [2], S. Eliseev [2,3], T. Eronen [1], U. Hager [1], J. Hakala [1], A. Jokinen [1,2,3], I. D. Moore, Yu. N. Novikov, H. Penttilä, A. Popov [2], S. Rahaman [1], S. Rinta-Antila [1], J. Rissanen [1], A. Saastamoinen [1,2], D. M. Seliverstov, T. Sonoda [1], G. Vorobjev [2,3], C. Weber [1], J. Äystö

Abstract

Nuclides in the vicinity of 94Ag have been studied with the Penning trap mass spectrometer JYFLTRAP at the Ion-Guide Separator On-Line. The masses of the two-proton-decay daughter 92Rh and the beta-decay daughter 94Pd of the high-spin isomer in 94Ag have been measured, and the masses of 93Pd and 94Ag have been deduced. When combined with the data from the one-proton or two-proton-decay experiments, the results lead to contradictory mass excess values for the high-spin isomer in 94Ag, -46370(170) or -44970(100) keV, corresponding to excitation energies of 6960(400) or 8360(370) keV, respectively.

Preparing isomerically pure beams of short-lived nuclei at JYFLTRAP

T. Eronen, V. -V. Elomaa, U. Hager, J. Hakala, A. Jokinen, A. Kankainen, S. Rahaman, J. Rissanen [1], C. Weber [1], J. Aysto

Abstract

A new procedure to prepare isomerically clean samples of ions with a mass resolving power of more than 100,000 has been developed at the JYFLTRAP tandem Penning trap system. The method utilises a dipolar rf-excitation of the ion motion with separated oscillatory fields in the precision trap. During a subsequent retransfer to the purification trap, the contaminants are rejected and as a consequence, the remaining bunch is isomerically cleaned. This newly-developed method is suitable for very high-resolution cleaning and is at least a factor of five faster than the methods used so far in Penning trap mass spectrometry.

Time-separated oscillatory fields for high-precision mass measurements on short-lived Al and Ca nuclides

S. George [1,2], G. Audi [3], B. Blank [4], K. Blaum [1,2,5], M. Breitenfeldt [6], U. Hager [7], F. Herfurth [1], A. Herlert [8], A. Kellerbauer [5], H. -J. Kluge [1,9], M. Kretzschmar [2], D. Lunney [3], R. Savreux [1], S. Schwarz [10], L. Schweikhard [6], C. Yazidjian [1]

Abstract

High-precision Penning trap mass measurements on the stable nuclide 27Al as well as on the short-lived radionuclides 26Al and 38,39Ca have been performed by use of radiofrequency excitation with time-separated oscillatory fields, i.e. Ramsey's method, as recently introduced for the excitation of the ion motion in a Penning trap, was applied. A comparison with the conventional method of a single continuous excitation demonstrates its advantage of up to ten times shorter measurements. The new mass values of 26,27Al clarify conflicting data in this specific mass region. In addition, the resulting mass values of the superallowed beta-emitter 38Ca as well as of the groundstate of the beta-emitter 26Al m confirm previous measurements and corresponding theoretical corrections of the ft-values.

Precise atomic masses of neutron-rich Br and Rb nuclei close to the r-process path

S. Rahaman, U. Hager, V. -V. Elomaa, T. Eronen, J. Hakala, A. Jokinen, A. Kankainen, P. Karvonen, I. D. Moore, H. Penttila, S. Rinta-Antila [1], J. Rissanen [1], A. Saastamoinen [1], T. Sonoda [1], J. Aysto

Abstract

The Penning trap mass spectrometer JYFLTRAP, coupled to the Ion-Guide Isotope Separator On-Line (IGISOL) facility at Jyvaskyla, was employed to measure the atomic masses of neutron rich 85 to 92Br and 94 to 97Rb isotopes with a typical accuracy less than 10 keV. Discrepancies with the older data are discussed. Comparison to different mass models is presented. Details of nuclear structure, shell and subshell closures are investigated by studying the two-neutron separation energy and the shell gap energy.

Separated Oscillatory Fields for High-Precision Penning Trap Mass Spectrometry

S. George [1,2], S. Baruah [3], B. Blank [4], K. Blaum [1,2], M. Breitenfeldt [3], U. Hager [5], F. Herfurth [1], A. Herlert [6], A. Kellerbauer [7], H. J. Kluge [1,8], M. Kretzschmar [2], D. Lunney [9], R. Savreux [1], S. Schwarz [10], L. Schweikhard [3], C. Yazidjian [1]

Abstract

Ramsey's method of separated oscillatory fields is applied to the excitation of the cyclotron motion of short-lived ions in a Penning trap to improve the precision of their measured mass. The theoretical description of the extracted ion-cyclotron-resonance line shape is derived out and its correctness demonstrated experimentally by measuring the mass of the short-lived $^{38}$Ca nuclide with an uncertainty of $1.6\cdot 10^{-8}$ using the ISOLTRAP Penning trap mass spectrometer at CERN. The mass value of the superallowed beta-emitter $^{38}$Ca is an important contribution for testing the conserved-vector-current hypothesis of the electroweak interaction. It is shown that the Ramsey method applied to mass measurements yields a statistical uncertainty similar to that obtained by the conventional technique ten times faster.