L. J. Wang

Second-order Doppler frequency shifts of trapped ions in a linear Paul trap

S. N. Miao [1], J. W. Zhang [1], Y. Zheng [1,2], H. R. Qin [1,2], N. C. Xin [1], Y. T. Chen [1], J. Z. Han [1], L. J. Wang [1,2]

Abstract

The accurate evaluation of the second-order Doppler frequency shift (SODFS) of trapped ions in a linear Paul trap has been studied with experiments and molecular dynamics (MD) simulations. The motion of trapped ions in the trap has three contributions, and we focus on the ion excess micromotion, which is rarely discussed when evaluating the SODFS. Based on the hypothesis that the ion density is uniformly distributed in the radial direction, we propose a new model to accurately evaluate the total SODFS for ion microwave clocks. The effectiveness of the model has been verified both in simulation and experiment, especially for ion ensemble with temperature less than 100 mK. We believe that our new model offers advantages in accurately evaluating the SODFS for the ion trap, especially those of laser-cooled ion microwave clocks based on large ion clouds.

Determination of hyperfine splittings and Landé $g_J$ factors of $5s~^2S_{1/2}$ and $5p~^2P_{1/2,3/2}$ states of $^{111,113}$Cd$^+$ for a microwave frequency standard

J. Z. Han [1], R. Si [2], H. R. Qin [3], N. C. Xin [1], Y. T. Chen [1], S. N. Miao [1], C. Y. Chen [2], J. W. Zhang [1], L. J. Wang [1,3]

Abstract

Regarding trapped-ion microwave-frequency standards, we report on the determination of hyperfine splittings and Landé $g_J$ factors of $^{111,113}$Cd$^+$. The hyperfine splittings of the $5p~^2P_{3/2}$ state of $^{111,113}$Cd$^+$ ions were measured using laser-induced fluorescence spectroscopy. The Cd$^+$ ions were confined in a linear Paul trap and sympathetically cooled by Ca$^+$ ions. Furthermore, the hyperfine splittings and Landé $g_J$ factors of the $5s~^2S_{1/2}$ and $5p~^2P_{1/2,3/2}$ levels of $^{111,113}$Cd$^+$ were calculated with greater accuracy using the multiconfiguration Dirac--Hartree--Fock scheme. The measured hyperfine splittings and the Dirac--Hartree--Fock calculation values were cross-checked, thereby further guaranteeing the reliability of our results. The results provided in this work can improve the signal-to-noise ratio of the clock transition and the accuracy of the second-order Zeeman shift correction, and subsequently the stability and accuracy of the microwave frequency standard based on trapped Cd$^+$ ions.

Progress toward a microwave frequency standard based on laser-cooled large scale 171Yb+ ion crystal

N. C. Xin, H. R. Qin, S. N. Miao, Y. T. Chen, J. Z. Han, J. W. Zhang, L. J. Wang

Abstract

We report on progress towards a microwave frequency standard based on a laser-cooled 171Yb+ ion trap system. The electronics, lasers, and magnetic shields are integrated into a single physical package. With over 1E5 ions are stably trapped, the system offers a high signal-to-noise ratio Ramsey line-shape. In comparison with previous work, the frequency instability of a 171Yb+ microwave clock was further improved to $8.5 \times {10^{ - 13}}/\sqrt τ$ for averaging times between 10 and 1000 s.

Precision determination of the ground-state hyperfine splitting of trapped ${}^{113}$Cd${}^{+}$ ions

S. N. Miao [1], J. W. Zhang [1], H. R. Qin [2], N. C. Xin [1], J. Z. Han [1], L. J. Wang [1,2]

Abstract

We measured the ground-state hyperfine splitting of trapped ${}^{113}$Cd${}^{+}$ ions to be 15199862855.02799(27) Hz with a fractional uncertainty of $1.8\times10^{-14}$. The ions were trapped and laser-cooled in a linear quadrupole Paul trap. The fractional frequency stability was measured to be ${4.2} \times 10^{-13}/\sqrtτ $, obtained from Ramsey fringes of high signal-to-noise ratio and taken over a measurement time of nearly 5 hours, which is close to the short-term stability limit estimated from the Dick effect. Our result is consistent with previous reported values, but the measurement precision is four times better than the best result obtained to date.

An Optical Clock Based on Coherent Population Trapping of Alkaline-earth Ions

Z. H. Lu [1], L. J. Wang [1]

Abstract

An ultra-stable optical clock based on coherent population trapping effect of alkaline-earth ions, such as Ca$^+$, Sr$^+$, Ba$^+$, is analyzed here. The proposed transitions use the odd isotopes, so that the frequency shift is insensitive to the applied magnetic field. To enhance the signal, a large number of ions are trapped in a linear Paul trap, and laser cooled to crystallize such that the ions are in the Lamb-Dicke regime to avoid first order Doppler shift. Other relevant frequency shifts are also analyzed. Further techniques to improve the stability of the clock signal are discussed.