M. Block

Direct determination of the atomic mass difference of Re187 and Os187 for neutrino physics and cosmochronology

D. A. Nesterenko, S. Eliseev [1], K. Blaum [1], M. Block [3], S. Chenmarev [1,4], A. Doerr, C. Droese [5,6,1,4], P. E. Filianin, M. Goncharov [1], E. Minaya Ramirez [1,2,4], Yu. N. Novikov, L. Schweikhard [5,3,6], V. V. Simon

Abstract

For the first time a direct determination of the atomic mass difference of 187Re and 187Os has been performed with the Penning-trap mass spectrometer SHIPTRAP applying the novel phase-imaging ion-cyclotron-resonance technique. The obtained value of 2492(30stat)(15sys) eV is in excellent agreement with the Q values determined indirectly with microcalorimetry and thus resolves a long-standing discrepancy with older proportional counter measurements. This is essential for the determination of the neutrino mass from the beta-decay of 187Re as planned in future microcalorimetric measurements. In addition, an accurate mass difference of 187Re and 187Os is also important for the assessment of 187Re for cosmochronology.

Direct Measurement of the Mass Difference of Ho163 and Dy163 Solves the Q-Value Puzzle for the Neutrino Mass Determination

S. Eliseev [1], K. Blaum [1], M. Block [2,3,4], S. Chenmarev [1,5], H. Dorrer [4,6,7,2,3,8], Ch. E. Duellmann, C. Enss [9,1,5], P. E. Filianin, L. Gastaldo [9], M. Goncharov [1,10,2,5,11], U. Koester, F. Lautenschlaeger, Yu. N. Novikov, A. Rischka [1], R. X. Schuessler, L. Schweikhard [12,6,7], A. Tuerler

Abstract

The atomic mass difference of 163Ho and 163Dy has been directly measured with the Penning trap mass spectrometer SHIPTRAP applying the novel phase imaging ion cyclotron resonance technique. Our measurement has solved the long standing problem of large discrepancies in the Q value of the electron capture in 163Ho determined by different techniques. Our measured mass difference shifts the current Q value of 2555(16) eV evaluated in the Atomic Mass Evaluation 2012 [G. Audi et al., Chin. Phys. C 36, 1157 (2012)] by more than 7 sigma to 2833(30stat)(15sys) eV/c2. With the new mass difference it will be possible, e.g., to reach in the first phase of the ECHo experiment a statistical sensitivity to the neutrino mass below 10 eV, which will reduce its present upper limit by more than an order of magnitude.

Extending the applicability of an open-ring trap to perform experiments with a single laser-cooled ion

J. M. Cornejo, M. Colombano [1], J. Doménech, M. Block [2,3,4], P. Delahaye [5,1], D. Rodríguez

Abstract

An open-ring ion trap, also referred to as transparent trap was initially built up to perform $β$-$ν$ correlation experiments with radioactive ions. This trap geometry is also well suited to perform experiments with laser-cooled ions, serving for the development of a new type of Penning trap, in the framework of the project TRAPSENSOR at the University of Granada. The goal of this project is to use a single $^{40}$Ca$^+$ ion as detector for single-ion mass spectrometry. Within this project and without any modification to the initial electrode configuration, it was possible to perform Doppler cooling on $^{40}$Ca$^+$ ions, starting from large clouds and reaching single ion sensitivity. This new feature of the trap might be important also for other experiments with ions produced at Radioactive Ion Beam (RIB) facilities. In this publication, the trap and the laser system will be described, together with their performance with respect to laser cooling applied to large ion clouds down to a single ion.

Position-sensitive ion detection in precision Penning trap mass spectrometry

G. Eitel, M. Block, A. Czasch, M. Dworschak, S. George, O. Jagutzki, J. Ketelaer, J. Ketter, Sz. Nagy, D. Rodriguez, C. Smorra [1], K. Blaum [1]

Abstract

A commercial, position-sensitive ion detector was used for the first time for the time-of-flight ion-cyclotron resonance detection technique in Penning trap mass spectrometry. In this work, the characteristics of the detector and its implementation in a Penning trap mass spectrometer will be presented. In addition, simulations and experimental studies concerning the observation of ions ejected from a Penning trap are described. This will allow for a precise monitoring of the state of ion motion in the trap.

TRIGA-SPEC: A setup for mass spectrometry and laser spectroscopy at the research reactor TRIGA Mainz

J. Ketelaer, J. Krämer, D. Beck, K. Blaum, M. Block, K. Eberhardt, G. Eitel, R. Ferrer, C. Geppert, S. George, F. Herfurth, J. Ketter, Sz. Nagy, D. Neidherr, R. Neugart [1], W. Nörtershäuser, J. Repp [1], C. Smorra [1], N. Trautmann [1], C. Weber [1]

Abstract

The research reactor TRIGA Mainz is an ideal facility to provide neutron-rich nuclides with production rates sufficiently large for mass spectrometric and laser spectroscopic studies. Within the TRIGA-SPEC project, a Penning trap as well as a beam line for collinear laser spectroscopy are being installed. Several new developments will ensure high sensitivity of the trap setup enabling mass measurements even on a single ion. Besides neutron-rich fission products produced in the reactor, also heavy nuclides such as 235-U or 252-Cf can be investigated for the first time with an off-line ion source. The data provided by the mass measurements will be of interest for astrophysical calculations on the rapid neutron-capture process as well as for tests of mass models in the heavy-mass region. The laser spectroscopic measurements will yield model-independent information on nuclear ground-state properties such as nuclear moments and charge radii of neutron-rich nuclei of refractory elements far from stability. This publication describes the experimental setup as well as its present status.