P. Micke

Orders of Magnitude Improved Cyclotron-Mode Cooling for Non-Destructive Spin Quantum Transition Spectroscopy with Single Trapped Antiprotons

B. M. Latacz [1,2], M. Fleck [1,3,2,4], J. I. Jaeger, G. Umbrazunas [1,5], B. P. Arndt [1,4,6], S. R. Erlewein [1,4], E. J. Wursten [1], J. A. Devlin [1,2], P. Micke [1,2,4], F. Abbass [7], D. Schweitzer [7], M. Wiesinger [4], C. Will [4], H. Yildiz [7], K. Blaum [4], Y. Matsuda [3], A. Mooser [4], C. Ospelkaus [8,9], A. Soter [5], W. Quint [6], J. Walz [7,10], Y. Yamazaki [1], C. Smorra [1,7], S. Ulmer [1,11]

Abstract

We demonstrate efficient sub-thermal cooling of the modified cyclotron mode of a single trapped antiproton and reach particle temperatures $T_+=E_+/k_\text{B}$ below $200\,$mK in preparation times shorter than $500\,$s. This corresponds to the fastest resistive single-particle cyclotron cooling to sub-thermal temperatures ever demonstrated. By cooling trapped particles to such low energies, we demonstrate the detection of antiproton spin transitions with an error-rate $<0.000025$, more than three orders of magnitude better than in previous best experiments. This method will have enormous impact on multi-Penning-trap experiments that measure magnetic moments with single nuclear spins for tests of matter/antimatter symmetry, high-precision mass-spectrometry, and measurements of electron $g$-factors bound to highly-charged ions that test quantum electrodynamics.

BASE-STEP: A transportable antiproton reservoir for fundamental interaction studies

C. Smorra [1,2], F. Abbass [1], M. Bohman [2,3], Y. Dutheil [4], A. Hobl [5], D. Popper [1], B. Arndt [2,3,6], B. B. Bauer [1,2], J. A. Devlin [2,4], S. Erlewein [2,3,4], M. Fleck [2,3,4], J. I. Jäger, B. M. Latacz [2,4], P. Micke [3,4], M. Schiffelholz [7,8], G. Umbrazunas [2,9], M. Wiesinger [3], C. Will [3], E. Wursten [2,4], H. Yildiz [1], K. Blaum [3], Y. Matsuda [10], A. Mooser [3], C. Ospelkaus [7,8], W. Quint [6], A. Soter [9], J. Walz [1,11], Y. Yamazaki [2], S. Ulmer [2,12]

Abstract

Currently, the only worldwide source of low-energy antiprotons is the AD/ELENA facility located at CERN. To date, all precision measurements on single antiprotons have been conducted at this facility and provide stringent tests of the fundamental interactions and their symmetries. However, the magnetic field fluctuations from the facility operation limit the precision of upcoming measurements. To overcome this limitation, we have designed the transportable antiproton trap system BASE-STEP to relocate antiprotons to laboratories with a calm magnetic environment. We anticipate that the transportable antiproton trap will facilitate enhanced tests of CPT invariance with antiprotons, and provide new experimental possibilities of using transported antiprotons and other accelerator-produced exotic ions. We present here the technical design of the transportable trap system. This includes the transportable superconducting magnet, the cryogenic inlay consisting of the trap stack and the detection systems, and the differential pumping section to suppress the residual gas flow into the cryogenic trap chamber.

An ultralow-noise superconducting radio-frequency ion trap for frequency metrology with highly charged ions

J. Stark [1,2], C. Warnecke [1,2], S. Bogen [1], S. Chen [1,3], E. A. Dijck [1,2], S. Kühn, M. K. Rosner [1,2], A. Graf [1], J. Nauta [1,2], J. -H. Oelmann [1,2,4], L. Schmöger, M. Schwarz [1,4], D. Liebert [1,4], L. J. Spieß, S. A. King [4], T. Leopold [4], P. Micke [1,4], P. O. Schmidt [4,5], T. Pfeifer [1], J. R. Crespo López-Urrutia

Abstract

We present a novel ultrastable superconducting radio-frequency (RF) ion trap realized as a combination of an RF cavity and a linear Paul trap. Its RF quadrupole mode at 34.52 MHz reaches a quality factor of $Q\approx2.3\times 10^5$ at a temperature of 4.1 K and is used to radially confine ions in an ultralow-noise pseudopotential. This concept is expected to strongly suppress motional heating rates and related frequency shifts which limit the ultimate accuracy achieved in advanced ion traps for frequency metrology. Running with its low-vibration cryogenic cooling system, electron beam ion trap and deceleration beamline supplying highly charged ions (HCI), the superconducting trap offers ideal conditions for optical frequency metrology with ionic species. We report its proof-of-principle operation as a quadrupole mass filter with HCI, and trapping of Doppler-cooled ${}^9\text{Be}^+$ Coulomb crystals.

The Heidelberg compact electron beam ion traps

P. Micke [1,2], S. Kühn, L. Buchauer [1], J. R. Harries [3,1], T. M. Bücking, K. Blaum [1], A. Cieluch [1], A. Egl [1], D. Hollain [1], S. Kraemer [1], T. Pfeifer [1], P. O. Schmidt [2,4,1], R. X. Schüssler, Ch. Schweiger [1,5,6,7], T. Stöhlker, S. Sturm [1], R. N. Wolf [1], S. Bernitt [1,7], J. R. Crespo López-Urrutia

Abstract

Electron beam ion traps (EBIT) are ideal tools for both production and study of highly charged ions (HCI). In order to reduce their construction, maintenance, and operation costs we have developed a novel, compact, room-temperature design, the Heidelberg Compact EBIT (HC-EBIT). Four already commissioned devices operate at the strongest fields (up to 0.86 T) reported for such EBITs using permanent magnets, run electron beam currents up to 80 mA and energies up to 10 keV. They demonstrate HCI production, trapping, and extraction of pulsed Ar$^{16+}$ bunches and continuous 100 pA ion beams of highly charged Xe up to charge state 29+, already with a 4 mA, 2 keV electron beam. Moreover, HC-EBITs offer large solid-angle ports and thus high photon count rates, e. g., in x-ray spectroscopy of dielectronic recombination in HCIs up to Fe$^{24+}$, achieving an electron-energy resolving power of $E/ΔE > 1500$ at 5 keV. Besides traditional on-axis electron guns, we have also implemented a novel off-axis gun for laser, synchrotron, and free-electron laser applications, offering clear optical access along the trap axis. We report on its first operation at a synchrotron radiation facility demonstrating resonant photoexcitation of highly charged oxygen.

Closed-cycle, low-vibration 4 K cryostat for ion traps and other applications

P. Micke [1,2], J. Stark [1,3], S. A. King [2], T. Leopold [2], T. Pfeifer [1,2], L. Schmöger, M. Schwarz [1,2], L. J. Spieß, P. O. Schmidt [2,4,1], J. R. Crespo López-Urrutia

Abstract

In-vacuo cryogenic environments are ideal for applications requiring both low temperatures and extremely low particle densities. This enables reaching long storage and coherence times for example in ion traps, essential requirements for experiments with highly charged ions, quantum computation, and optical clocks. We have developed a novel cryostat continuously refrigerated with a pulse-tube cryocooler and providing the lowest vibration level reported for such a closed-cycle system with 1 W cooling power for a <5 K experiment. A decoupling system suppresses vibrations from the cryocooler by three orders of magnitude down to a level of 10 nm peak amplitudes in the horizontal plane. Heat loads of about 40 W (at 45 K) and 1 W (at 4 K) are transferred from an experimental chamber, mounted on an optical table, to the cryocooler through a vacuum-insulated massive 120 kg inertial copper pendulum. The 1.4 m long pendulum allows installation of the cryocooler in a separate, acoustically isolated machine room. In the laser laboratory, we measured the residual vibrations using an interferometric setup. The positioning of the 4 K elements is reproduced to better than a few micrometer after a full thermal cycle to room temperature. Extreme high vacuum on the $10^{-15}$ mbar level is achieved. In collaboration with the Max-Planck-Intitut für Kernphysik (MPIK), such a setup is now in operation at the Physikalisch-Technische Bundesanstalt (PTB) for a next-generation optical clock experiment using highly charged ions.