T. Ruster

Entanglement-based dc magnetometry with separated ions

T. Ruster [1], H. Kaufmann [1], M. A. Luda [1], V. Kaushal [1], C. T. Schmiegelow [1], F. Schmidt-Kaler [1], U. G. Poschinger [1]

Abstract

We demonstrate sensing of inhomogeneous dc magnetic fields by employing entangled trapped ions, which are shuttled in a segmented Paul trap. As \textit{sensor states}, we use Bell states of the type $\left|\uparrow\downarrow\right>+\text{e}^{\text{i}\varphi}\left|\downarrow\uparrow\right>$ encoded in two $^{40}$Ca$^+$ ions stored at different locations. Due to the linear Zeeman effect, the relative phase $\varphi$ serves to measure the magnetic field difference between the constituent locations, while common-mode fluctuations are rejected. Consecutive measurements on sensor states encoded in the $\text{S}_{1/2}$ ground state and in the $\text{D}_{5/2}$ metastable state are used to separate an ac Zeeman shift from the linear dc Zeeman effect. We measure magnetic field differences over distances of up to $6.2~\text{mm}$, with accuracies of around 300~fT, sensitivities down to $12~\text{pT} / \sqrt{\text{Hz}}$, and spatial resolutions down to $10~\text{nm}$. For optimizing the information gain while maintaining a high dynamic range, we implement an algorithm for Bayesian frequency estimation.

Cryogenic setup for trapped ion quantum computing

M. F. Brandl, M. W. van Mourik, L. Postler [1], A. Nolf [1], K. Lakhmanskiy [1,2,3], R. R. Paiva, S. Möller, N. Daniilidis [3], H. Häffner, V. Kaushal [4], T. Ruster [4], C. Warschburger [4], H. Kaufmann [4], U. G. Poschinger, F. Schmidt-Kaler [4], P. Schindler [1], T. Monz [1], R. Blatt [1,5]

Abstract

We report on the design of a cryogenic setup for trapped ion quantum computing containing a segmented surface electrode trap. The heat shield of our cryostat is designed to attenuate alternating magnetic field noise, resulting in 120~dB reduction of 50~Hz noise along the magnetic field axis. We combine this efficient magnetic shielding with high optical access required for single ion addressing as well as for efficient state detection by placing two lenses each with numerical aperture 0.23 inside the inner heat shield. The cryostat design incorporates vibration isolation to avoid decoherence of optical qubits due to the motion of the cryostat. We measure vibrations of the cryostat of less than $\pm$20~nm over 2~s. In addition to the cryogenic apparatus, we describe the setup required for an operation with $^{\mathrm{40}}$Ca$^{\mathrm{+}}$ and $^{\mathrm{88}}$Sr$^{\mathrm{+}}$ ions. The instability of the laser manipulating the optical qubits in $^{\mathrm{40}}$Ca$^{\mathrm{+}}$ is characterized yielding a minimum of its Allan deviation of 2.4$\cdot$10$^{\mathrm{-15}}$ at 0.33~s. To evaluate the performance of the apparatus, we trapped $^{\mathrm{40}}$Ca$^{\mathrm{+}}$ ions, obtaining a heating rate of 2.14(16)~phonons/s and a Gaussian decay of the Ramsey contrast with a 1/e-time of 18.2(8)~ms.

Measurement of dipole matrix elements with a single trapped ion

M. Hettrich [1], T. Ruster [1], H. Kaufmann [1], C. F. Roos [2,3,1], C. T. Schmiegelow, F. Schmidt-Kaler [1], U. G. Poschinger [1]

Abstract

We demonstrate a new method for the direct measurement of atomic dipole transition matrix elements based on techniques developed for quantum information purposes. The scheme consists of measuring dispersive and absorptive off-resonant light-ion interactions and is applicable to many atomic species. We determine the dipole matrix element pertaining to the Ca II H line, i.e. the 4$^2$S$_{1/2} \leftrightarrow $ 4$^2$P$_{1/2}$ transition of $^{40}$Ca$^+$, for which we find the value 2.8928(43) ea$_0$. Moreover, the method allows us to deduce the lifetime of the 4$^2$P$_{1/2}$ state to be 6.904(26) ns, which is in agreement with predictions from recent theoretical calculations and resolves a longstanding discrepancy between calculated values and experimental results.