Yang Shen

Development of a compact cryogenic Penning trap with permanent magnets: An intermediate step toward the Shanghai Penning Trap

Tianhang Zhang [1], Jiawei Wang [1], Jialin Liu [1], Jingtian Wei [2], Jiaxuan Ji [1], Jifei Wu [1], Zichen Su [1], Yiming Xie [1], Liangyu Huang [1], Ke Yao [1], Yang Shen [1], Yaming Zou [1], Baoren Wei [1], Bingsheng Tu [1]

Abstract

Penning traps, renowned for their unparalleled precision in determining fundamental properties such as mass and magnetic moments, are cornerstone instruments in modern physics. Their applications span from nuclear structure studies to stringent tests of quantum electrodynamics and CPT invariance. Although Penning traps have been demonstrated for fundamental studies, often employing superconducting magnets, their high cost and operational complexity remain challenges. In this work, we report the development of a compact cryogenic Penning trap that utilizes a permanent magnet to provide a confining magnetic field, offering a more economical and flexible alternative. We have successfully demonstrated all core functionalities of this system, including ion generation, transport, confinement, manipulation, and signal detection. This compact trap not only serves as a vital technical testbed for the development of the Shanghai Penning Trap, but also establishes a cryogenic Penning-trap experiment platform for ion trapping and cooling applications as well as envisaged spectroscopic studies applications.

Experimental Access to Observing Decay from Extremely Long-Lived Metastable Electronic States via Penning Trap Spectrometry

Bingsheng Tu [1], Ran Si [1], Yang Shen [1], Jiarong Wang [1], Baoren Wei [1], Chongyang Chen [1], Ke Yao [1], Yaming Zou [1]

Abstract

Long-lived ionic quantum states known as metastable electronic states in highly-charged ions (HCIs) are of great interest in fundamental physics. Especially, it generates transitions with very narrow natural linewidth which is a promising candidate for use in the next generation HCI atomic clocks to reach an accuracy below $10^{-19}$. A recent experiment reported in [Nature,581(7806) 2020], used Penning trap mass spectrometry to measure the energy of an extremely long-lived metastable electronic state, thus opening doors to search for HCI clock transitions. Building upon prior research, this study introduces an experimental proposal with the goal of measuring lifetimes of the metastable states beyond seconds. Our approach employs a sequential pulse-and-phase measurement scheme, allowing for direct observations of the decay processes from metastable electronic states through single-ion mass spectrometry in a Penning trap. This measurement poses a significant challenge to conventional techniques like fluorescence detection. To demonstrate the effectiveness of this method, we conducted a comprehensive simulation under real experimental conditions, yielding promising results in a specific scenario. Two suitable candidates are proposed for testing this method, and the state-of-the-art MCDHF theory are employed for accurate energy levels and transition rate calculations. Some future prospects in the experimental determinations of a wide range of energy and lifetimes of long-lived metastable electronic states, probing hyperfine and magnetic quenching effects on high-order forbidden transitions and search for highly quality HCI clock transitions are discussed.

A low-energy compact Shanghai-Wuhan electron beam ion trap for extraction of highly charged ions

Shiyong Liang [1,2,3], Qifeng Lu [4,5], Xincheng Wang [6], Yang Yang [4,5], Ke Yao [4,5], Yang Shen [4,5], Baoren Wei [4,5], Jun Xiao [4,5], Shaolong Chen [1,2,3], Pengpeng Zhou [1,2,3], Wei Sun [1,2], Yonghui Zhang [1], Yao Huang [1,2], Hua Guan [1,2], Xin Tong [1], Chengbin Li [1], Yaming Zou [4,5], Tingyun Shi [1,7], Kelin Gao [1,2,7]

Abstract

A low-energy, compact and superconducting electron beam ion trap (the Shanghai-Wuhan EBIT or SW-EBIT) for extraction of highly charged ions is presented. The magnetic field in the central drift tube of the SW-EBIT is approximately 0.21 T produced by a pair of high-temperature superconducting coils. The electron-beam energy of the SW-EBIT is in the range of 30-4000 eV, and the maximum electron-beam current is up to 9 mA. Acting as a source of highly charged ions, the ion-beam optics for extraction is integrated, including an ion extractor and an einzel lens. A Wien filter is then used to measure the charge-state distribution of the extracted ions. In this work, the tungsten ions below the charge state of 15 have been produced, extracted, and analyzed. The charge-state distributions and spectra in the range of 530-580 nm of tungsten ions have been measured simultaneously with the electron-beam energy of 279 eV and 300 eV, which preliminarily indicates that the 549.9 nm line comes from $W^{14+}$.