Nils Scharnhorst

Experimental and theoretical investigation of a multi-mode cooling scheme using multiple EIT resonances

Nils Scharnhorst [1,2], Javier Cerrillo [3], Johannes Kramer [1], Ian D. Leroux [1], Jannes B. Wübbena, Alex Retzker [4], Piet O. Schmidt [1,2]

Abstract

We introduce and demonstrate double-bright electromagnetically induced transparency (D-EIT) cooling as a novel approach to EIT cooling. By involving an additional ground state, two bright states can be shifted individually into resonance for cooling of motional modes of frequencies that may be separated by more than the width of a single EIT cooling resonance. This allows three-dimensional ground state cooling of a $^{40}$Ca$^+$ ion trapped in a linear Paul trap with a single cooling pulse. Measured cooling rates and steady-state mean motional quantum numbers for this D-EIT cooling are compared with those of standard EIT cooling as well as concatenated standard EIT cooling pulses for multi-mode cooling. Experimental results are compared to full density matrix calculations. We observe a failure of the theoretical description within the Lamb-Dicke regime that can be overcome by a time-dependent rate theory. Limitations of the different cooling techniques and possible extensions to multi-ion crystals are discussed.

Analysis of thermal radiation in ion traps for optical frequency standards

Miroslav Doležal, Petr Balling, Peter B R Nisbet-Jones, Steven A King, Jonathan M Jones, Hugh A Klein, Patrick Gill, Thomas Lindvall, Anders E Wallin, Mikko Merimaa, Christian Tamm, Christian Sanner, Nils Huntemann, Nils Scharnhorst, Ian D Leroux, Piet O Schmidt, Tobias Burgermeister, Tanja E Mehlstäubler, Ekkehard Peik

Abstract

In many of the high-precision optical frequency standards with trapped atoms or ions that are under development to date, the AC Stark shift induced by thermal radiation leads to a major contribution to the systematic uncertainty. We present an analysis of the inhomogeneous thermal environment experienced by ions in various types of ion traps. Finite element models which allow the determination of the temperature of the trap structure and the temperature of the radiation were developed for 5 ion trap designs, including operational traps at PTB and NPL and further optimized designs. Models were refined based on comparison with infrared camera measurement until an agreement of better than 10% of the measured temperature rise at critical test points was reached. The effective temperature rises of the radiation seen by the ion range from 0.8 K to 2.1 K at standard working conditions. The corresponding fractional frequency shift uncertainties resulting from the uncertainty in temperature are in the 10-18 range for optical clocks based on the Sr+ and Yb+ E2 transitions, and even lower for Yb+ E3, In+ and Al+. Issues critical for heating of the trap structure and its predictability were identified and design recommendations developed.