Peter Beiersdorfer

High-Resolution Laboratory Measurements of M-shell Fe EUV Line Emission using EBIT-I

Alexander J. Fairchild [1,2], Natalie Hell [2], Peter Beiersdorfer [2,3], Gregory V. Brown [2], Megan E. Eckart [2], Michael Hahn [1], Daniel W. Savin [1]

Abstract

Solar physicists routinely utilize observations of Ar-like Fe IX and Cl-like Fe X emission to study a variety of solar structures. However, unidentified lines exist in the Fe IX and Fe X spectra, greatly impeding the spectroscopic diagnostic potential of these ions. Here, we present measurements using the Lawrence Livermore National Laboratory EBIT-I electron beam ion trap in the wavelength range 238-258 A. These studies enable us to unambiguously identify the charge state associated with each of the observed lines. This wavelength range is of particular interest because it contains the Fe IX density diagnostic line ratio 241.74 A/244.91 A, which is predicted to be one of the best density diagnostics of the solar corona, as well as the Fe X 257.26 A magnetic-field-induced transition. We compare our measurements to the Fe IX and Fe X lines tabulated in CHIANTI v10.0.1, which is used for modeling the solar spectrum. In addition, we have measured previously unidentified Fe X lines that will need to be added to CHIANTI and other spectroscopic databases.

Laboratory Calibrations of Fe XII-XIV Line-Intensity Ratios for Electron Density Diagnostics

Thusitha P. Arthanayaka, Peter Beiersdorfer, Gregory V. Brown, Ming Feng Gu [3], Michael Hahn [1], Natalie Hell [1], Tom E. Lockard, Daniel Wolf Savin

Abstract

We have used an electron beam ion trap to measure electron-density-diagnostic line-intensity ratios for extreme ultraviolet lines from F XII, XIII, and XIV at wavelengths of 185-205 255-276 Angstroms. These ratios can be used as density diagnostics for astrophysical spectra and are especially relevant to solar physics. We found that density diagnostics using the Fe XIII 196.53/202.04 and the Fe XIV 264.79/274.21 and 270.52A/274.21 line ratios are reliable using the atomic data calculated with the Flexible Atomic Code. On the other hand, we found a large discrepancy between the FAC theory and experiment for the commonly used Fe XII (186.85 + 186.88)/195.12 line ratio. These FAC theory calculations give similar results to the data tabulated in CHIANTI, which are commonly used to analyze solar observations. Our results suggest that the discrepancies seen between solar coronal density measurements using the Fe XII (186.85 + 186.88)/195.12 and Fe XIII 196.54/202.04 line ratios are likely due to issues with the atomic calculations for Fe XII.

Laboratory Measurements of X-Ray Emission from Highly Charged Argon Ions

Esra Bulbul [1,2], Adam Foster [2], Gregory V. Brown [3], Mark W. Bautz [1], Peter Beiersdorfer [3], Natalie Hell [3], Caroline Kilbourne [4], Ralph Kraft [2], Richard Kelley [4], Maurice A. Leutenegger [4,5], Eric D. Miller [1], F. Scott Porter [4], Randall K. Smith [2]

Abstract

Uncertainties in atomic models will introduce noticeable additional systematics in calculating the flux of weak dielectronic recombination (DR) satellite lines, affecting the detection and flux measurements of other weak spectral lines. One important example is the Ar XVII He-beta DR, which is expected to be present in emission from the hot intracluster medium (ICM) of galaxy clusters and could impact measurements of the flux of the 3.5 keV line that has been suggested as a secondary emission from a dark matter interaction. We perform a set of experiments using the Lawrence Livermore National Laboratory's electron beam ion trap (EBIT-I) and the X-Ray Spectrometer quantum calorimeter (XRS/EBIT), to test the Ar XVII He-beta DR origin of the 3.5 keV line. We measured the X-ray emission following resonant DR onto helium-like and lithium-like Argon using EBIT-I's Maxwellian simulator mode at a simulated electron temperature of Te=1.74 keV. The measured flux of the Ar XVII He-beta DR lined is too weak to account for the flux in the 3.5 keV line assuming reasonable plasma parameters. We, therefore, rule out Ar XVII He-beta DR as a significant contributor to the 3.5 keV line. A comprehensive comparison between the atomic theory and the EBIT experiment results is also provided.

Laboratory Measurement and Theoretical Modeling of K-shell X-ray Lines from Inner-shell Excited and Ionized Ions of Oxygen

Ming Feng Gu [1], Mike Schmidt [2,3], Peter Beiersdorfer [2], Hui Chen [2], Daniel B. Thorn [2,4], Elmar Träbert, Ehud Behar [5], Steven M. Kahn [1]

Abstract

We present high resolution laboratory spectra of K-shell X-ray lines from inner-shell excited and ionized ions of oxygen, obtained with a reflection grating spectrometer on the electron beam ion trap (EBIT-I) at the Lawrence Livermore National Laboratory. Only with a multi-ion model including all major atomic collisional and radiative processes, are we able to identify the observed K-shell transitions of oxygen ions from \ion{O}{3} to \ion{O}{6}. The wavelengths and associated errors for some of the strongest transitions are given, taking into account both the experimental and modeling uncertainties. The present data should be useful in identifying the absorption features present in astrophysical sources, such as active galactic nuclei and X-ray binaries. They are also useful in providing benchmarks for the testing of theoretical atomic structure calculations.