R. K. Hanley

Robust and fast microwave-driven quantum logic for trapped-ion qubits

M. A. Weber [1], M. F. Gely [1], R. K. Hanley [1], T. P. Harty [1], A. D. Leu [1], C. M. Löschnauer, D. P. Nadlinger [1], D. M. Lucas [1]

Abstract

Microwave-driven logic is a promising alternative to laser control in scaling trapped-ion based quantum processors. However, such electronic gates have yet to match the speed offered by their laser-driven counterparts. Here, we implement Mølmer-Sørensen two-qubit gates on $^{43}\text{Ca}^+$ hyperfine clock qubits in a cryogenic ($\approx25~\text{K}$) surface trap, driven by near-field microwaves. We achieve gate durations of $154~μ\text{s}$ (with $1.0(2)\%$ error) and $331~μ\text{s}$ ($0.5(1)\%$ error), which approaches the performance of typical laser-driven gates. In the $331~μ\text{s}$ gate, we demonstrate a new Walsh-modulated dynamical decoupling scheme which suppresses errors due to fluctuations in the qubit frequency as well as imperfections in the decoupling drive itself.

Cryogenic ion trap system for high-fidelity near-field microwave-driven quantum logic

M. A. Weber, C. Löschnauer, J. Wolf, M. F. Gely, R. K. Hanley, J. F. Goodwin [1], C. J. Ballance [1], T. P. Harty [1], D. M. Lucas [1]

Abstract

We report the design, fabrication, and characterization of a cryogenic ion trap system for the implementation of quantum logic driven by near-field microwaves. The trap incorporates an on-chip microwave resonator with an electrode geometry designed to null the microwave field component that couples directly to the qubit, while giving a large field gradient for driving entangling logic gates. We map the microwave field using a single $^{43}$Ca$^+$ ion, and measure the ion trapping lifetime and motional mode heating rates for one and two ions.

Precision measurement of the $^{43}$Ca$^{+}$ nuclear magnetic moment

R. K. Hanley [1], D. T. C. Allcock [1,2], T. P. Harty [1], M. A. Sepiol [1], D. M. Lucas [1]

Abstract

We report precision measurements of the nuclear magnetic moment of \textsuperscript{43}Ca\textsuperscript{+}, made by microwave spectroscopy of the 4s $^2$S$_{1/2}$ $\left|F=4, M=0\right\rangle \rightarrow \left|F=3, M=1\right\rangle$ ground level hyperfine clock transition at a magnetic field of $\approx$ 146 G, using a single laser-cooled ion in a Paul trap. We measure a clock transition frequency of $f = 3199941076.920 \pm 0.046$ Hz, from which we determine $μ_I / μ_{\rm{N}} = -1.315350(9)(1)$, where the uncertainty (9) arises from uncertainty in the hyperfine $A$ constant, and the (1) arises from the uncertainty in our measurement. This measurement is not corrected for diamagnetic shielding due to the bound electrons. We make a second measurement which is less precise but agrees with the first. We use our $μ_I$ value, in combination with previous NMR results, to extract the change in shielding constant of calcium ions due to solvation in D$_2$O: $Δσ= -0.00022(1)$.