Wolfgang Quint

Penning-Trap Mass Measurement of Helium-4

Sangeetha Sasidharan, Olesia Bezrodnova, Sascha Rau, Wolfgang Quint, Sven Sturm, Klaus Blaum

Abstract

Light-Ion Trap (LIONTRAP), a high-precision Penning-trap mass spectrometer, was used to determine the atomic mass of $^{4}$He. Here, we report a 12 parts-per-trillion measurement of the mass of a $^{4}$He$^{2+}$ ion, $m(^{4}\text{He}^{2+}$) = $4.001\:506\:179\:651 (48)$ u. From this, the atomic mass of the neutral atom can be determined without loss of precision: $m(^{4}\text{He})$ = $4.002\:603\:254\:653 (48)$ u. This result is slightly more precise than the current CODATA18 literature value but deviates by 6.6 standard deviations. This is a post-peer-review, pre-copy edit version of an article published in PRL. The final version is available online at https://doi.org/10.1103/PhysRevLett.131.093201.

Trap-integrated fluorescence detection based on silicon photomultipliers in a cryogenic Penning trap

Markus Wiesinger, Florian Stuhlmann, Matthew A. Bohman, Peter Micke, Christian Will, Hüseyin Yildiz, Fatma Abbass, Bela P. Arndt, Jack A. Devlin, Stefan Erlewein, Markus Fleck, Julia I. Jäger, Barbara M. Latacz, Daniel Schweitzer, Gilbertas Umbrazunas, Elise Wursten, Klaus Blaum, Yasuyuki Matsuda, Andreas Mooser, Wolfgang Quint, Anna Soter, Jochen Walz, Christian Smorra, Stefan Ulmer

Abstract

We present a fluorescence-detection system for laser-cooled 9Be+ ions based on silicon photomultipliers (SiPM) operated at 4 K and integrated into our cryogenic 1.9 T multi-Penning-trap system. Our approach enables fluorescence detection in a hermetically-sealed cryogenic Penning-trap chamber with limited optical access, where state-of-the-art detection using a telescope and photomultipliers at room temperature would be extremely difficult. We characterize the properties of the SiPM in a cryocooler at 4 K, where we measure a dark count rate below 1/s and a detection efficiency of 2.5(3) %. We further discuss the design of our cryogenic fluorescence-detection trap, and analyze the performance of our detection system by fluorescence spectroscopy of 9Be+ ion clouds during several runs of our experiment.

Penning-trap mass measurements of the deuteron and the HD+ molecular ion

Sascha Rau [1,2], Fabian Heiße, Florian Köhler-Langes, Sangeetha Sasidharan [1,2], Raphael Haas [2,3,4,5], Dennis Renisch [3,4,2,5], Christoph E. Düllmann, Wolfgang Quint [2], Sven Sturm [1], Klaus Blaum [1]

Abstract

The masses of the lightest atomic nuclei and the electron mass are interlinked and are crucial in a wide range of research fields, with their values affecting observables in atomic, molecular and neutrino physics as well as metrology. The most precise values for these fundamental parameters come from Penning-trap mass spectrometry, which achieves relative mass uncertainties in the range of $10^{-11}$. However, redundancy checks using data from different experiments reveal significant inconsistencies in the masses of the proton ($m_p$), the deuteron ($m_d$) and helion ($m_\text{he}$), amounting to $5$ standard deviations for the term $Δ=m_p+m_d-m_{\text{he}}$, which suggests that the uncertainty of these values may have been underestimated. Here we present results from absolute mass measurements of the deuteron and the ${HD}^+$ molecular ion against $^{12}C$ as a mass reference. Our value for the deuteron $m_d=2.013\,553\,212\,535 (17)$u supersedes the precision of the literature value by a factor of $2.4$ and deviates from this by $4.8$ standard deviations. With a relative uncertainty of $8$ parts per trillion (ppt) this is the most precise mass value measured directly in atomic mass units. Furthermore, the measurement of the ${HD}^+$ molecular ion, $m({HD}^+)=3.021\,378\,241\,561\,(61)$u, not only allows for a rigorous consistency check of our measurements of the masses of the deuteron (this work) and proton, but also establishes an additional link for the masses of tritium and helium-3 to the atomic mass unit. Combined with a recent measurement of the deuteron-to-proton mass ratio the uncertainty of the reference value of $m_p$ can be reduced by a factor of three. This is a post-peer-review, pre-copyedit version of an article published in Nature. The final authenticated version is available online at https://doi.org/10.1038/s41586-020-2628-7

High-precision mass spectrometer for light ions

Fabian Heiße, Sascha Rau, Florian Köhler-Langes, Wolfgang Quint, Günter Werth, Sven Sturm, Klaus Blaum

Abstract

The precise knowledge of the atomic masses of light atomic nuclei, e.g. the proton, deuteron, triton and helion, is of great importance for several fundamental tests in physics. However, the latest high-precision measurements of these masses carried out at different mass spectrometers indicate an inconsistency of five standard deviations. To determine the masses of the lightest ions with a relative precision of a few parts per trillion and investigate this mass problem a cryogenic multi-Penning trap setup, LIONTRAP (Light ION TRAP), was constructed. This allows an independent and more precise determination of the relevant atomic masses by measuring the cyclotron frequency of single trapped ions in comparison to that of a single carbon ion. In this paper the measurement concept and the first doubly compensated cylindrical electrode Penning trap, are presented. Moreover, the analysis of the first measurement campaigns of the proton's and oxygen's atomic mass is described in detail, resulting in mp = 1.007 276 466 598 (33) u and m(16O)= 15.994 914 619 37 (87) u. The results on these data sets have already been presented in [F. Heisse et al., Phys. Rev. Lett. 119, 033001 (2017)]. For the proton's atomic mass, the uncertainty was improved by a factor of three compared to the 2014 CODATA value.

The electron mass from $g$-factor measurements on hydrogen-like carbon $^{12}$C$^{5+}$

Florian Köhler, Sven Sturm, Anke Kracke, Günter Werth, Wolfgang Quint, Klaus Blaum

Abstract

The electron mass in atomic mass units has been determined with a relative uncertainty of $2.8\cdot 10^{-11}$, which represents a 13-fold improvement of the 2010 CODATA value. The underlying measurement principle combines a high-precision measurement of the Larmor-to-cyclotron frequency ratio on a single hydrogen-like carbon ion in a Penning trap with a corresponding very accurate $g$-factor calculation. Here, we present the measurement results in detail, including a comprehensive discussion of the systematic shifts and their uncertainties. A special focus is set on the various sources of phase jitters, which are essential for the understanding of the applied line-shape model for the $g$-factor resonance.

Half-open Penning trap with efficient light collection for precision laser spectroscopy of highly charged ions

David von Lindenfels, Manuel Vogel, Wolfgang Quint, Gerhard Birkl, Marco Wiesel

Abstract

We have conceived, built and operated a 'half-open' cylindrical Penning trap for the confinement and laser spectroscopy of highly charged ions. This trap allows fluorescence detection employing a solid angle which is about one order of magnitude larger than in conventional cylindrical Penning traps. At the same time, the desired electrostatic and magnetostatic properties of a closed-endcap cylindrical Penning trap are preserved in this congfiuration. We give a detailed account on the design and confinement properties, a characterization of the trap and show first results of light collection with in-trap produced highly charged ions.