Christian Smorra

Trapping of electrons and $^{40}\textrm{Ca}^+$ ions in a dual-frequency Paul trap

Vladimir Mikhailovskii [1,2,3], Natalija Sheth [1,2,3], Guofeng Qu [4,5], Michal Hejduk [6], Niklas Vilhelm Lausti [6], K. T. Satyajith [7], Christian Smorra [3,8], Günther Werth, Neha Yadav [9], Qian Yu [9], Clemens Matthiesen [9], Hartmut Häffner, Ferdinand Schmidt-Kaler [3], Hendrik Bekker [1,2,3], Dmitry Budker [1,2,3,9]

Abstract

We demonstrate the operation of a dual-frequency Paul trap and characterize its performance by storing either electrons or calcium ions while applying two quadrupole fields simultaneously which oscillate at $Ω_\textrm{fast} = 2π\times 1.6$ GHz and $Ω_\textrm{slow} = 2π\times 2$ MHz. The particles are loaded and stored in the trap under various conditions followed by detection employing an electron multiplier tube. We find that tens of electrons or ions can be trapped for up to ten milliseconds and a small fraction remains trapped even after hundreds of milliseconds. During dual-frequency operation we find that while the number of trapped electrons rapidly decreases with increase of the $Ω_\textrm{slow}$ field amplitude, the number of trapped ions shows no dependence on the $Ω_\textrm{fast}$ field amplitude as supported by our extensive numerical simulations. We aim to use a similar trap for synthesising antihydrogen from antiprotons and positrons. Accordingly, we discuss open challenges such as the co-trapping of oppositely charged species and particle trap duration.

Trap-integrated fluorescence detection based on silicon photomultipliers in a cryogenic Penning trap

Markus Wiesinger, Florian Stuhlmann, Matthew A. Bohman, Peter Micke, Christian Will, Hüseyin Yildiz, Fatma Abbass, Bela P. Arndt, Jack A. Devlin, Stefan Erlewein, Markus Fleck, Julia I. Jäger, Barbara M. Latacz, Daniel Schweitzer, Gilbertas Umbrazunas, Elise Wursten, Klaus Blaum, Yasuyuki Matsuda, Andreas Mooser, Wolfgang Quint, Anna Soter, Jochen Walz, Christian Smorra, Stefan Ulmer

Abstract

We present a fluorescence-detection system for laser-cooled 9Be+ ions based on silicon photomultipliers (SiPM) operated at 4 K and integrated into our cryogenic 1.9 T multi-Penning-trap system. Our approach enables fluorescence detection in a hermetically-sealed cryogenic Penning-trap chamber with limited optical access, where state-of-the-art detection using a telescope and photomultipliers at room temperature would be extremely difficult. We characterize the properties of the SiPM in a cryocooler at 4 K, where we measure a dark count rate below 1/s and a detection efficiency of 2.5(3) %. We further discuss the design of our cryogenic fluorescence-detection trap, and analyze the performance of our detection system by fluorescence spectroscopy of 9Be+ ion clouds during several runs of our experiment.

Millicharged dark matter detection with ion traps

Dmitry Budker [1,2,3], Peter W. Graham [4,5], Harikrishnan Ramani [4], Ferdinand Schmidt-Kaler [1,2], Christian Smorra [6], Stefan Ulmer [7]

Abstract

We propose the use of trapped ions for detection of millicharged dark matter. Millicharged particles will scatter off the ions, giving a signal either in individual events or in the overall heating rate of the ions. Ion traps have several properties which make them ideal detectors for such a signal. First, ion traps have demonstrated significant isolation of the ions from the environment, greatly reducing the background heating and event rates. Second, ion traps can have low thresholds for detection of energy deposition, down to $\sim \text{neV}$. Third, since the ions are charged, they naturally have large cross sections for scattering with the millicharged particles, further enhanced by the low velocities of the thermalized millicharges. Despite ion-trap setups being optimized for other goals, we find that existing measurements put new constraints on millicharged dark matter which are many orders of magnitude beyond previous bounds. For example, for a millicharge dark matter mass $m_Q=10~\textrm{GeV}$ and charge $10^{-3}$ of the electron charge, ion traps limit the local density to be $n_Q \lesssim 1 \, \textrm{cm}^{-3}$, a factor $\sim 10^8$ better than current constraints. Future dedicated ion trap experiments could reach even further into unexplored parameter space.

Precision measurements of the fundamental properties of the proton and antiproton

Christian Smorra, Andreas Mooser

Abstract

Precision measurements comparing the fundamental properties of conjugate particles and antiparticles constitute stringent tests of CPT invariance. We review recent precision measurements of the BASE collaboration, which improved the uncertainty of the proton and antiproton magnetic moments and the comparison of the proton-to-antiproton charge-to-mass ratio. These measurements constitute the most stringent tests of CPT invariance with antiprotons. Further, we discuss the improved limit on the antiproton lifetime based on the storage of a cloud of antiprotons in the unique BASE reservoir trap. Based on these recent advances, we discuss ongoing technical developments which comprise a coupling trap for the sympathetic cooling of single (anti-)protons with laser-cooled beryllium ions, a transportable trap to relocate antiproton measurements into a high-precision laboratory, and a new experiment to measure the magnetic moment of helium-3 ions, which will improve absolute precision magnetometry.