Systematic uncertainty due to background-gas collisions in trapped-ion optical clocks

A. M. Hankin [1,2], E. R. Clements [1,2], Y. Huang [3], S. M. Brewer [1,2], J. -S. Chen [1,2], C. W. Chou [1], D. B. Hume [1], D. R. Leibrandt [1,2]

Abstract

We describe a framework for calculating the frequency shift and uncertainty of trapped-ion optical atomic clocks caused by background-gas collisions, and apply this framework to an $^{27}$Al$^+$ clock to enable a total fractional systematic uncertainty below $10^{-18}$. For this clock, with 38(19) nPa of room temperature H$_2$ background gas, we find that collisional heating generates a non-thermal distribution of motional states with a mean time-dilation shift of order $10^{-16}$ at the end of a 150 ms probe, which is not detected by sideband thermometry energy measurements. However, the contribution of collisional heating to the spectroscopy signal is highly suppressed and we calculate the BGC shift to be $-0.6(2.4)\times 10^{-19}$, where the shift is due to collisional heating time-dilation and the uncertainty is dominated by the worst case $\pm π/2$ bound used for collisional phase shift of the $^{27}$Al$^+$ superposition state. We experimentally validate the framework and determine the background-gas pressure in situ using measurements of the rate of collisions that cause reordering of mixed-species ion pairs.

An $^{27}$Al$^{+}$ quantum-logic clock with systematic uncertainty below $10^{-18}$

S. M. Brewer [1,2], J. -S. Chen [1,2], A. M. Hankin [1,2], E. R. Clements [1,2], C. W. Chou [1], D. J. Wineland [1,2,3], D. B. Hume [1], D. R. Leibrandt [1,2]

Abstract

We describe an optical atomic clock based on quantum-logic spectroscopy of the $^1$S$_0$ $\leftrightarrow$ $^3$P$_0$ transition in $^{27}$Al$^{+}$ with a systematic uncertainty of ${9.4 \times 10^{-19}}$ and a frequency stability of ${1.2\times10^{-15}/\sqrtτ}$. A $^{25}$Mg$^{+}$ ion is simultaneously trapped with the $^{27}$Al$^{+}$ ion and used for sympathetic cooling and state readout. Improvements in a new trap have led to reduced secular motion heating, compared to previous $^{27}$Al$^{+}$ clocks, enabling clock operation with ion secular motion near the three-dimensional ground state. Operating the clock with a lower trap drive frequency has reduced excess micromotion compared to previous $^{27}$Al$^{+}$ clocks. Both of these improvements have led to a reduced time-dilation shift uncertainty. Other systematic uncertainties including those due to blackbody radiation and the second-order Zeeman effect have also been reduced.

Trapped-Ion State Detection through Coherent Motion

D. B. Hume [1], C. W. Chou [1], D. R. Leibrandt [1], M. J. Thorpe [1], D. J. Wineland [1], T. Rosenband [1]

Abstract

We demonstrate a general method for state detection of trapped ions that can be applied to a large class of atomic and molecular species. We couple a "spectroscopy" ion (Al+) to a "control" ion (Mg+) in the same trap and perform state detection through off-resonant laser excitation of the spectroscopy ion that induces coherent motion. The motional amplitude, dependent on the spectroscopy ion state, is measured either by time-resolved photon counting, or by resolved sideband excitations on the control ion. The first method provides a simplified way to distinguish "clock" states in Al+, which avoids ground state cooling and sideband transitions. The second method reduces spontaneous emission and optical pumping on the spectroscopy ion, which we demonstrate by nondestructively distinguishing Zeeman sublevels in the 1S0 ground state of Al+.

Demonstration of a scalable, multiplexed ion trap for quantum information processing

D. R. Leibrandt [1], J. Labaziewicz [1], R. J. Clark [1], I. L. Chuang [1], R. J. Epstein [2], C. Ospelkaus [2], J. H. Wesenberg [2], J. J. Bollinger [2], D. Leibfried [2], D. J. Wineland [2], D. Stick [3], J. Sterk [3], C. Monroe [3], C. -S. Pai [4], Y. Low [4], R. Frahm [4], R. E. Slusher [5]

Abstract

A scalable, multiplexed ion trap for quantum information processing is fabricated and tested. The trap design and fabrication process are optimized for scalability to small trap size and large numbers of interconnected traps, and for integration of control electronics and optics. Multiple traps with similar designs are tested with Cd+, Mg+, and Sr+ ions at room temperature and with Sr+ at 6 K, with respective ion lifetimes of 90 s, 300 +/- 30 s, 56 +/- 6 s, and 4.5 +/- 1.1 hours. The motional heating rate for Mg+ at room temperature and a trap frequency of 1.6 MHz is measured to be 7 +/- 3 quanta per millisecond. For Sr+ at 6 K and 540 kHz the heating rate is measured to be 220 +/- 30 quanta per second.

Experimental investigation of planar ion traps

C. E. Pearson [1], D. R. Leibrandt [1], W. S. Bakr [1], W. J. Mallard [1], K. R. Brown [1], I. L. Chuang [1]

Abstract

Chiaverini et al. [Quant. Inf. Comput. 5, 419 (2005)] recently suggested a linear Paul trap geometry for ion trap quantum computation that places all of the electrodes in a plane. Such planar ion traps are compatible with modern semiconductor fabrication techniques and can be scaled to make compact, many zone traps. In this paper we present an experimental realization of planar ion traps using electrodes on a printed circuit board to trap linear chains of tens of 0.44 micron diameter charged particles in a vacuum of 15 Pa (0.1 torr). With these traps we address concerns about the low trap depth of planar ion traps and develop control electrode layouts for moving ions between trap zones without facing some of the technical difficulties involved in an atomic ion trap experiment. Specifically, we use a trap with 36 zones (77 electrodes) arranged in a cross to demonstrate loading from a traditional four rod linear Paul trap, linear ion movement, splitting and joining of ion chains, and movement of ions through intersections. We further propose an additional DC biased electrode above the trap which increases the trap depth dramatically, and a novel planar ion trap geometry that generates a two dimensional lattice of point Paul traps.