K. G. Leach

First direct $^{7}$Be electron capture $Q$-value measurement towards high-precision BSM neutrino physics searches

R. Bhandari [1], G. Bollen [2,3], T. Brunner [4], N. D. Gamage [2], A. Hamaker [2,3], Z. Hockenbery [4,5], M. Horana Gamage [1], D. K. Keblbeck [1], K. G. Leach [6,2], D. Puentes [2,3], M. Redshaw [1,2], R. Ringle [2], S. Schwarz [2], C. S. Sumithrarachchi [2], I. Yandow [2,3]

Abstract

We report the first direct measurement of the nuclear electron capture (EC) decay $Q$-value of $^{7}$Be $\rightarrow$ $^{7}$Li via high-precision Penning trap mass spectrometry (PTMS). This was performed using the LEBIT Penning trap located at the National Superconducting Cyclotron Laboratory/Facility for Rare Isotope Beams (NSCL/FRIB) using the newly commissioned Batch-Mode Ion-Source (BMIS) to deliver the unstable $^{7}$Be$^{+}$ samples. With a measured value of $Q_{EC}$ = 861.963(23) keV this result is also three times more precise than any previous determination of this quantity. This improved precision, and accuracy of the $^7$Be EC decay $Q$-value is critical for ongoing experiments that measure the recoiling nucleus in this system as a signature to search for beyond Standard Model (BSM) neutrino physics using $^7$Be-doped superconducting sensors.

'Searching for a needle in a haystack;' A Ba-tagging approach for an upgraded nEXO experiment

H. Rasiwala, K. Murray, Y. Lan, C. Chambers, M. Cvitan, T. Brunner, R. Collister, T. Daniels, R. Elmansali, W. Fairbank, R. Gornea, G. Gratta, T. Koffas, A. A. Kwiatkowski, K. G. Leach, A. Lennarz, C. Malbrunot [1], D. Ray [1], R. Shaikh [1], L. Yang [1]

Abstract

nEXO is a proposed experiment that will search for neutrinoless double-beta decay (0$νββ$) in 5-tonnes of liquid xenon (LXe), isotopically enriched in $^{136}$Xe. A technique called Ba-tagging is being developed as a potential future upgrade for nEXO to detect the $^{136}$Xe double-beta decay daughter isotope, $^{136}$Ba. An efficient Ba-tagging technique has the potential to boost nEXO's 0$νββ$ sensitivity by essentially suppressing non-double-beta decay background events. A conceptual approach for the extraction from the detector volume, trapping, and identification of a single Ba ion from 5 tonnes of LXe is presented, along with initial results from the commissioning of one of its subsystems, a quadrupole mass filter.

Collision-Induced Dissociation at TRIUMF's Ion Trap for Atomic and Nuclear science

A. Jacobs, C. Andreoiu, J. Bergmann, T. Brunner, T. Dickel, I. Dillmann, E. Dunling, J. Flowerdew, L. Graham, G. Gwinner, Z. Hockenbery, B. Kootte, Y. Lan, K. G. Leach, E. Leistenschneider, E. M. Lykiardopoulou, V. Monier, I. Mukul, S. F. Paul, W. R. Plaß, M. P. Reiter, C. Scheidenberger, R. Thompson, J. L Tracy, C. Will, M. E. Wieser, M. Yavor, J. Dilling [1], A. A. Kwiatkowski

Abstract

The performance of high-precision mass spectrometry of radioactive isotopes can often be hindered by large amounts of contamination, including molecular species, stemming from the production of the radioactive beam. In this paper, we report on the development of Collision-Induced Dissociation (CID) as a means of background reduction for experiments at TRIUMF's Ion Trap for Atomic and Nuclear science (TITAN). This study was conducted to characterize the quality and purity of radioactive ion beams and the reduction of molecular contaminants to allow for mass measurements of radioactive isotopes to be done further from nuclear stability. This is the first demonstration of CID at an ISOL-type radioactive ion beam facility, and it is shown that molecular contamination can be reduced up to an order of magnitude.

Improved Limit on Tensor Currents in the Weak Interaction from $^8$Li $β$ Decay

M. T. Burkey [1,2,3], G. Savard [2,3], A. T. Gallant [1], N. D. Scielzo [1,3,4], T. Y. Hirsh [4,3,5], L. Varriano [2,3], G. H. Sargsyan [6], K. D. Launey [6], M. Brodeur [7], D. P. Burdette [7,3], E. Heckmaier [8,1], K. Joerres [6], J. W. Klimes [3], K. Kolos [1], A. Laminack [6], K. G. Leach [9], A. F. Levand [3], B. Longfellow [1,10,3], B. Maaß, S. T. Marley [6], G. E. Morgan [6], P. Mueller [3], R. Orford [3,11], S. W. Padgett [1,3], A. Pérez Galván, J. R. Pierce [2,3], D. Ray [4,3], R. Segel [12], K. Siegl [7], K. S. Sharma [4], B. S. Wang [1]

Abstract

The electroweak interaction in the Standard Model (SM) is described by a pure vector-axial-vector structure, though any Lorentz-invariant component could contribute. In this work, we present the most precise measurement of tensor currents in the low-energy regime by examining the $β$-$\barν$ correlation of trapped $^{8}$Li ions with the Beta-decay Paul Trap. We find $a_{βν} = -0.3325 \pm 0.0013_{stat} \pm 0.0019_{syst}$ at $1σ$ for the case of coupling to right-handed neutrinos $(C_T=-C_T')$, which is consistent with the SM prediction.

Mass Measurements of Neutron-Rich Gallium Isotopes Refine Production of Nuclei of the First r-Process Abundance Peak in Neutron Star Merger Calculations

M. P. Reiter, S. Ayet San Andrés, S. Nikas [3,4], J. Lippuner [5,6,7], C. Andreoiu [8], C. Babcock [2], B. R. Barquest, J. Bollig [2,9], T. Brunner [2,10], T. Dickel [1,3], J. Dilling [2,11], I. Dillmann [2,12], E. Dunling [2,13], G. Gwinner [14], L. Graham [2], C. Hornung [1], R. Klawitter [2,15], B. Kootte [2,14,12], A. A. Kwiatkowski, Y. Lan [2,11], D. Lascar [2,16,17], K. G. Leach, E. Leistenschneider [2,11,3,4,12,9,1], G. Martínez-Pinedo, J. E. McKay, S. F. Paul, W. R. Plaß, L. Roberts [18], H. Schatz [7,18,19], C. Scheidenberger [1,3], A. Sieverding [3,4,20,2], R. Steinbrügge, R. Thompson [21], M. E. Wieser, C. Will [1], D. Welch [18]

Abstract

We report mass measurements of neutron-rich Ga isotopes $^{80-85}$Ga with TRIUMF's Ion Trap for Atomic and Nuclear science (TITAN). The measurements determine the masses of $^{80-83}$Ga in good agreement with previous measurements. The masses of $^{84}$Ga and $^{85}$Ga were measured for the first time. Uncertainties between $25-48$ keV were reached. The new mass values reduce the nuclear uncertainties associated with the production of A $\approx$ 84 isotopes by the \emph{r}-process for astrophysical conditions that might be consistent with a binary neutron star (BNS) merger producing a blue kilonova. Our nucleosynthesis simulations confirm that BNS merger may contribute to the first abundance peak under moderate neutron-rich conditions with electron fractions $Y_e=0.35-0.38$.

Dawning of the N=32 shell closure seen through precision mass measurements of neutron-rich titanium isotopes

E. Leistenschneider [1,2,3,4], M. P. Reiter, S. Ayet San Andrés, B. Kootte [1,5], J. D. Holt, P. Navrátil, C. Babcock [1], C. Barbieri [6,1], B. R. Barquest, J. Bergmann [3], J. Bollig [1,7], T. Brunner [1,8], E. Dunling [1,9], A. Finlay [1,2], H. Geissel [3,4], L. Graham [1], F. Greiner [3], H. Hergert [10], C. Hornung [3], C. Jesch [3], R. Klawitter [1,11], Y. Lan [1,2], D. Lascar [1,12], K. G. Leach, W. Lippert [3,1,13,7], J. E. McKay, S. F. Paul, A. Schwenk [11,14,15], D. Short [1,16], J. Simonis [17,18,1,19], V. SomÃ, R. Steinbrügge, S. R. Stroberg, R. Thompson [20], M. E. Wieser, C. Will [3], M. Yavor [21], C. Andreoiu [16], T. Dickel [3,4], I. Dillmann [1,13], G. Gwinner [5,3,4], W. R. Plaß, C. Scheidenberger [3,4,1,13], A. A. Kwiatkowski, J. Dilling [1,2]

Abstract

A precision mass investigation of the neutron-rich titanium isotopes $^{51-55}$Ti was performed at TRIUMF's Ion Trap for Atomic and Nuclear science (TITAN). The range of the measurements covers the $N=32$ shell closure and the overall uncertainties of the $^{52-55}$Ti mass values were significantly reduced. Our results confirm the existence of a weak shell effect at $N=32$, establishing the abrupt onset of this shell closure. Our data were compared with state-of-the-art \textit{ab-initio} shell model calculations which, despite very successfully describing where the $N=32$ shell gap is strong, overpredict its strength and extent in titanium and heavier isotones. These measurements also represent the first scientific results of TITAN using the newly commissioned Multiple-Reflection Time-of-Flight Mass Spectrometer (MR-TOF-MS), substantiated by independent measurements from TITAN's Penning trap mass spectrometer.

High-precision $Q_{EC}$-value measurement of the superallowed $β^+$ emitter $^{22}$Mg and an evaluation of the $A=22$ isobaric triplet

M. P. Reiter, K. G. Leach, O. M. Drozdowski [1,4], S. R. Stroberg, J. D. Holt, C. Andreoiu [5], C. Babcock [1], B. Barquest [1], M. Brodeur [6], A. Finlay [7,1], M. Foster [8,1,7,9], A. T. Gallant, G. Gwinner [10], R. Klawitter [1,11], B. Kootte [7,1,12], A. A Kwiatkowski, Y. Lan [7,1], D. Lascar [1], E. Leistenschneider [7,1], A. Lennarz [1,13], S. Paul [1,12,14], R. Steinbrügge, R. I. Thompson, M. Wieser [14], J. Dilling [1,7]

Abstract

A direct $Q_{EC}$-value measurement of the superallowed $β^+$ emitter $^{22}$Mg was performed using TRIUMF's Ion Trap for Atomic and Nuclear science (TITAN). The direct ground-state to ground-state atomic mass difference between $^{22}$Mg and $^{22}$Na was determined to be $Q_{EC}=4781.40(22)$~keV, representing the most precise single measurement of this quantity to date. In a continued push towards calculating superallowed isospin-symmetry-breaking (ISB) corrections from first principles, ab-initio shell-model calculations of the $A=22$ IMME are also presented for the first time using the valence-space in-medium similarity renormalization group formalism. With particular starting two- and three-nucleon forces, this approach demonstrates a level of agreement with the experimental data that suggests reliable ab-initio calculations of superallowed ISB corrections are now possible.

Electroweak Decay Studies of Highly Charged Radioactive Ions with TITAN at TRIUMF

K. G. Leach, I. Dillmann [2], R. Klawitter [2,3], E. Leistenschneider [2,4], A. Lennarz [2], T. Brunner [2,5], D. Frekers [6], C. Andreiou [7,2], A. A. Kwiatkowski, J. Dilling [2]

Abstract

Several modes of electroweak radioactive decay require an interaction between the nucleus and bound electrons within the constituent atom. Thus, the probabilities of the respective decays are not only influenced by the structure of the initial and final states in the nucleus, but can also depend strongly on the atomic charge. Conditions suitable for the partial or complete ionization of these rare isotopes occur naturally in hot, dense astrophysical environments, but can also be artificially generated in the laboratory to selectively block certain radioactive decay modes. Direct experimental studies on such scenarios are extremely difficult due to the laboratory conditions required to generate and store radioactive ions at high charge states. A new electron-beam ion trap (EBIT) decay setup with the TITAN experiment at TRIUMF has successfully demonstrated such techniques for performing spectroscopy on the radioactive decay of highly charged ions.

Low-Background In-Trap Decay Spectroscopy with TITAN at TRIUMF

K. G. Leach, A. Lennarz [1,3], A. Grossheim [1], R. Klawitter [1,4], T. Brunner [1,5], A. Chaudhuri [1], U. Chowdhury [1,6,4,7], J. R. Crespo López-Urrutia, A. T. Gallant, A. A. Kwiatkowski, T. D. Macdonald, B. E. Schultz, S. Seeraji [2], C. Andreoiu [2], D. Frekers [3], J. Dilling [1]

Abstract

An in-trap decay spectroscopy setup has been developed and constructed for use with the TITAN facility at TRIUMF. The goal of this device is to observe weak electron-capture (EC) branching ratios for the odd-odd intermediate nuclei in the $ββ$ decay process. This apparatus consists of an up-to 6 Tesla, open-access spectroscopy ion-trap, surrounded radially by up to 7 planar Si(Li) detectors which are separated from the trap by thin Be windows. This configuration provides a significant increase in sensitivity for the detection of low-energy photons by providing backing-free ion storage and eliminating charged-particle-induced backgrounds. An intense electron beam is also employed to increase the charge-states of the trapped ions, thus providing storage times on the order of minutes, allowing for decay-spectroscopy measurements. The technique of multiple ion-bunch stacking was also recently demonstrated, which further extends the measurement possibilities of this apparatus. The current status of the facility and initial results from a $^{116}$In measurement are presented.

Sensitivity Increases for the TITAN Decay Spectroscopy Program

K. G. Leach, A. Lennarz [1,3], A. Grossheim [1], C. Andreoiu [2], J. Dilling [1,4], D. Frekers [3], M. Good [1], S. Seeraji [2]

Abstract

The TITAN facility at TRIUMF has recently initiated a program of performing decay spectroscopy measurements in an electron-beam ion-trap (EBIT). The unique environment of the EBIT provides backing-free storage of the radioactive ions, while guiding charged decay particles from the trap centre via the strong magnetic field. This measurement technique is able to provide a significant increase in detection sensitivity for photons which result from radioactive decay. A brief overview of this device is presented, along with methods of improving the signal-to-background ratio for photon detection by reducing Compton scattered events, and eliminating vibrational noise.

The TITAN in-trap decay spectroscopy facility at TRIUMF

K. G. Leach, A. Grossheim, A. Lennarz, T. Brunner, J. R. Crespo López-Urrutia, A. T. Gallant, M. Good, R. Klawitter, A. A. Kwiatkowski, T. Ma, T. D. Macdonald, S. Seeraji, M. C. Simon, C. Andreoiu, J. Dilling [1], D. Frekers [1]

Abstract

This article presents an upgraded in-trap decay spectroscopy apparatus which has been developed and constructed for use with TRIUMF's Ion Trap for Atomic and Nuclear science (TITAN). This device consists of an open-access electron-beam ion-trap (EBIT), which is surrounded radially by seven low-energy planar Si(Li) detectors. The environment of the EBIT allows for the detection of low-energy photons by providing backing-free storage of the radioactive ions, while guiding charged decay particles away from the trap centre via the strong (up to 6 T) magnetic field. In addition to excellent ion confinement and storage, the EBIT also provides a venue for performing decay spectroscopy on highly-charged radioactive ions. Recent technical advancements have been able to provide a significant increase in sensitivity for low-energy photon detection, towards the goal of measuring weak electron-capture branching ratios of the intermediate nuclei in the two-neutrino double beta ($2νββ$) decay process. The design, development, and commissioning of this apparatus are presented together with the main physics objectives. The future of the device and experimental technique are discussed.