T. Brunner

Collision-Induced Dissociation at TRIUMF's Ion Trap for Atomic and Nuclear science

A. Jacobs, C. Andreoiu, J. Bergmann, T. Brunner, T. Dickel, I. Dillmann, E. Dunling, J. Flowerdew, L. Graham, G. Gwinner, Z. Hockenbery, B. Kootte, Y. Lan, K. G. Leach, E. Leistenschneider, E. M. Lykiardopoulou, V. Monier, I. Mukul, S. F. Paul, W. R. Plaß, M. P. Reiter, C. Scheidenberger, R. Thompson, J. L Tracy, C. Will, M. E. Wieser, M. Yavor, J. Dilling [1], A. A. Kwiatkowski

Abstract

The performance of high-precision mass spectrometry of radioactive isotopes can often be hindered by large amounts of contamination, including molecular species, stemming from the production of the radioactive beam. In this paper, we report on the development of Collision-Induced Dissociation (CID) as a means of background reduction for experiments at TRIUMF's Ion Trap for Atomic and Nuclear science (TITAN). This study was conducted to characterize the quality and purity of radioactive ion beams and the reduction of molecular contaminants to allow for mass measurements of radioactive isotopes to be done further from nuclear stability. This is the first demonstration of CID at an ISOL-type radioactive ion beam facility, and it is shown that molecular contamination can be reduced up to an order of magnitude.

Dawning of the N=32 shell closure seen through precision mass measurements of neutron-rich titanium isotopes

E. Leistenschneider [1,2,3,4], M. P. Reiter, S. Ayet San Andrés, B. Kootte [1,5], J. D. Holt, P. Navrátil, C. Babcock [1], C. Barbieri [6,1], B. R. Barquest, J. Bergmann [3], J. Bollig [1,7], T. Brunner [1,8], E. Dunling [1,9], A. Finlay [1,2], H. Geissel [3,4], L. Graham [1], F. Greiner [3], H. Hergert [10], C. Hornung [3], C. Jesch [3], R. Klawitter [1,11], Y. Lan [1,2], D. Lascar [1,12], K. G. Leach, W. Lippert [3,1,13,7], J. E. McKay, S. F. Paul, A. Schwenk [11,14,15], D. Short [1,16], J. Simonis [17,18,1,19], V. SomÃ, R. Steinbrügge, S. R. Stroberg, R. Thompson [20], M. E. Wieser, C. Will [3], M. Yavor [21], C. Andreoiu [16], T. Dickel [3,4], I. Dillmann [1,13], G. Gwinner [5,3,4], W. R. Plaß, C. Scheidenberger [3,4,1,13], A. A. Kwiatkowski, J. Dilling [1,2]

Abstract

A precision mass investigation of the neutron-rich titanium isotopes $^{51-55}$Ti was performed at TRIUMF's Ion Trap for Atomic and Nuclear science (TITAN). The range of the measurements covers the $N=32$ shell closure and the overall uncertainties of the $^{52-55}$Ti mass values were significantly reduced. Our results confirm the existence of a weak shell effect at $N=32$, establishing the abrupt onset of this shell closure. Our data were compared with state-of-the-art \textit{ab-initio} shell model calculations which, despite very successfully describing where the $N=32$ shell gap is strong, overpredict its strength and extent in titanium and heavier isotones. These measurements also represent the first scientific results of TITAN using the newly commissioned Multiple-Reflection Time-of-Flight Mass Spectrometer (MR-TOF-MS), substantiated by independent measurements from TITAN's Penning trap mass spectrometer.

Trapped-ion decay spectroscopy towards the determination of ground-state components of double-beta decay matrix elements

T. Brunner [1,2], A. Lapierre [1], C. Andreoiu [3], M. Brodeur [4], P. Delheji [1], S. Ettenauer [1,5], D. Frekers [6,1,5,2], A. T. Gallant, R. Gernhäuser, A. Grossheim [1,2], R. Krücken, A. Lennarz [1,6], D. Lunney [7,2], D. Mücher, R. Ringle [1,8,9], M. C. Simon, V. V. Simon, S. K. L. Sjue, K. Zuber [10], J. Dilling [1,5]

Abstract

A new technique has been developed at TRIUMF's TITAN facility to perform in-trap decay spectroscopy. The aim of this technique is to eventually measure weak electron capture branching ratios (ECBRs) and by this to consequently determine GT matrix elements of $ββ$ decaying nuclei. These branching ratios provide important input to the theoretical description of these decays. The feasibility and power of the technique is demonstrated by measuring the ECBR of $^{124}$Cs.

Verifying the accuracy of the TITAN Penning-trap mass spectrometer

M. Brodeur [1,2], V. L. Ryjkov, T. Brunner [1,3], S. Ettenauer [1,2], A. T. Gallant [1,2,4,5], V. V. Simon, M. J. Smith, A. Lapierre [1], R. Ringle [1], P. Delheij [1], M. Good [1], D. Lunney [6], J. Dilling [1,2]

Abstract

TITAN (TRIUMF's Ion Traps for Atomic and Nuclear science) is an online facility designed to carry out high-precision mass measurements on singly and highly charged radioactive ions. The TITAN Penning trap has been built and optimized in order to perform such measurements with an accuracy in the sub ppb-range. A detailed characterization of the TITAN Penning trap is presented and a new compensation method is derived and demonstrated, verifying the performance in the range of sub-ppb.

First Use of High Charge States for Mass Measurements of Short-lived Nuclides in a Penning Trap

S. Ettenauer [1,2], M. C. Simon [1], A. T. Gallant [1,2], T. Brunner [1,3], U. Chowdhury [1,4], V. V. Simon [1,5,6], M. Brodeur [1,2,7], A. Chaudhuri [1], E. Mané, C. Andreoiu [8], G. Audi [9,5], J. R. Crespo López-Urrutia, P. Delheij [1], G. Gwinner [4], A. Lapierre [1,7], D. Lunney [1,9], M. R. Pearson [1], R. Ringle [7], J. Ullrich [5], J. Dilling [1,2]

Abstract

Penning trap mass measurements of short-lived nuclides have been performed for the first time with highly-charged ions (HCI), using the TITAN facility at TRIUMF. Compared to singly-charged ions, this provides an improvement in experimental precision that scales with the charge state q. Neutron-deficient Rb-isotopes have been charge bred in an electron beam ion trap to q = 8 - 12+ prior to injection into the Penning trap. In combination with the Ramsey excitation scheme, this unique setup creating low energy, highly-charged ions at a radioactive beam facility opens the door to unrivalled precision with gains of 1-2 orders of magnitude. The method is particularly suited for short-lived nuclides such as the superallowed β emitter 74Rb (T1/2 = 65 ms). The determination of its atomic mass and an improved QEC-value are presented.

TITAN's Digital RFQ Ion Beam Cooler and Buncher, Operation and Performance

T. Brunner [1], M. J. Smith, M. Brodeur [1], S. Ettenauer [1], A. T. Gallant, V. V. Simon, A. Chaudhuri A. Lapierre, E. Mané, R. Ringle, M. C. Simon, J. A. Vaz, P. Delheij, M. Good, M. R. Pearson, J. Dilling [2]

Abstract

We present a description of the Radio Frequency Quadrupole (RFQ) ion trap built as part of the TITAN facility. It consists of a gas-filled, segmented, linear Paul trap and is the first stage of the TITAN setup with the purpose of cooling and bunching radioactive ion beams delivered from ISAC-TRIUMF. This is the first such device to be driven digitally, i.e., using a high voltage ($V_{pp} = \rm{400 \, V}$), wide bandwidth ($0.2 < f < 1.2 \, \rm{MHz}$) square-wave as compared to the typical sinusoidal wave form. Results from the commissioning of the device as well as systematic studies with stable and radioactive ions are presented including efficiency measurements with stable $^{133}$Cs and radioactive $^{124, 126}$Cs. A novel and unique mode of operation of this device is also demonstrated where the cooled ion bunches are extracted in reverse mode, i.e., in the same direction as previously injected.