R. Ringle

High-precision Penning trap mass measurements of neutron-rich chlorine isotopes at the N=28 shell closure

H. Erington [1,2], G. Bollen [1,2], G. Dykstra [3], A. Hamaker [1,2], C. M. Ireland [1,2], C. R. Nicoloff [1,2], D. Puentes [1,2], R. Ringle [1,2], S. Schwarz [1], C. S. Sumithrarachchi [1], A. A. Valverde [4,5], I. T. Yandow [1,2]

Abstract

Although it is known that the $N=28$ spherical shell closure erodes, the strength of the closure with decreasing proton number $Z<20$ is an open question in nuclear structure. In this region of interest, direct high-precision mass measurements of neutron-rich $^{43-45}$Cl isotopes were performed at the Low Energy Beam and Ion Trap (LEBIT) when coupled to the National Superconducting Cyclotron Lab. The resulting mass excesses (MEs) are ME($^{43}$Cl) = -24114.4(1.7) keV, ME($^{44}$Cl) = -20450.8(10.6) keV, and ME($^{45}$Cl) = -18240.1(3.7) keV, and improve the uncertainty of these masses by up to a factor of ~40 compared to the previous values reported in the 2020 Atomic Mass Evaluation. Comparison to $\textit{ab initio}$ calculations using the Valence-Space In-Medium Similarity Renormalization Group (VS-IMSRG) shows good agreement up to and including the closure.

Off-line Commissioning of the St. Benedict Radiofrequency Quadrupole Cooler-Buncher

D. P. Burdette, R. Zite, M. Brodeur, A. A. Valverde, O. Bruce, R. Bualuan, A. Cannon, J. A. Clark, C. Davis, T. Florenzo, A. T. Gallant, J. Harkin, A. M. Houff, J. Li, B. Liu, J. Long, P. D. O'Malley, W. S. Porter, C. Quick [1], R. Ringle [1], F. Rivero [1], G. Savard [1], M. A. Yeck

Abstract

The St. Benedict ion trapping system, which aims to measure the $β-ν$ angular correlation parameter in superallowed-mixed mirror transitions, is under construction at the University of Notre Dame. These measurements will provide much-needed data to improve the accuracy of the $V_{ud}$ element of the CKM matrix. One of the major components of this system is the radio frequency quadrupole cooler-buncher, which is necessary to create low-emittance ion bunches for injection into the measurement Paul trap. The off-line commissioning of the cooler-buncher, using a potassium ion source, determined that the device could produce cooled ion bunches characterized by a 50-ns full-width-half-maximum time width. The commissioning results also determined the trapping efficiency to be 93(1)$\%$ and the trapping half-life to be 20.0(5) s.

Precision Mass Measurements of Neutron-Rich Co Isotopes Beyond N=40

C. Izzo [1,2], G. Bollen [1,3], M. Brodeur [4], M. Eibach [2,5], K. Gulyuz [2], J. D. Holt [6], J. M. Kelly [4], M. Redshaw [2,7,8], R. Ringle [2], R. Sandler [1,2,7,8], S. Schwarz [2], S. R. Stroberg [6], C. S. Sumithrarachchi [2], A. A. Valverde [1,2], A. C. C. Villari [3]

Abstract

The region near Z=28, N=40 is a subject of great interest for nuclear structure studies due to spectroscopic signatures in $^{68}$Ni suggesting a subshell closure at N=40. Trends in nuclear masses and their derivatives provide a complementary approach to shell structure investigations via separation energies. Penning trap mass spectrometry has provided precise measurements for a number of nuclei in this region, however a complete picture of the mass surfaces has so far been limited by the large uncertainty remaining for nuclei with N > 40 along the iron and cobalt chains. Here we present the first Penning trap measurements of $^{68,69}$Co, performed at the Low-Energy Beam and Ion Trap facility at the National Superconducting Cyclotron Laboratory. In addition, we perform ab initio calculations of ground state and two-neutron separation energies of cobalt isotopes with the valence-space in-medium similarity renormalization group approach based on a particular set of two- and three-nucleon forces which predict saturation in infinite matter. We discuss the importance of these measurements and calculations for understanding the evolution of nuclear structure near $^{68}$Ni.

Trapped-ion decay spectroscopy towards the determination of ground-state components of double-beta decay matrix elements

T. Brunner [1,2], A. Lapierre [1], C. Andreoiu [3], M. Brodeur [4], P. Delheji [1], S. Ettenauer [1,5], D. Frekers [6,1,5,2], A. T. Gallant, R. Gernhäuser, A. Grossheim [1,2], R. Krücken, A. Lennarz [1,6], D. Lunney [7,2], D. Mücher, R. Ringle [1,8,9], M. C. Simon, V. V. Simon, S. K. L. Sjue, K. Zuber [10], J. Dilling [1,5]

Abstract

A new technique has been developed at TRIUMF's TITAN facility to perform in-trap decay spectroscopy. The aim of this technique is to eventually measure weak electron capture branching ratios (ECBRs) and by this to consequently determine GT matrix elements of $ββ$ decaying nuclei. These branching ratios provide important input to the theoretical description of these decays. The feasibility and power of the technique is demonstrated by measuring the ECBR of $^{124}$Cs.

Verifying the accuracy of the TITAN Penning-trap mass spectrometer

M. Brodeur [1,2], V. L. Ryjkov, T. Brunner [1,3], S. Ettenauer [1,2], A. T. Gallant [1,2,4,5], V. V. Simon, M. J. Smith, A. Lapierre [1], R. Ringle [1], P. Delheij [1], M. Good [1], D. Lunney [6], J. Dilling [1,2]

Abstract

TITAN (TRIUMF's Ion Traps for Atomic and Nuclear science) is an online facility designed to carry out high-precision mass measurements on singly and highly charged radioactive ions. The TITAN Penning trap has been built and optimized in order to perform such measurements with an accuracy in the sub ppb-range. A detailed characterization of the TITAN Penning trap is presented and a new compensation method is derived and demonstrated, verifying the performance in the range of sub-ppb.

First Use of High Charge States for Mass Measurements of Short-lived Nuclides in a Penning Trap

S. Ettenauer [1,2], M. C. Simon [1], A. T. Gallant [1,2], T. Brunner [1,3], U. Chowdhury [1,4], V. V. Simon [1,5,6], M. Brodeur [1,2,7], A. Chaudhuri [1], E. Mané, C. Andreoiu [8], G. Audi [9,5], J. R. Crespo López-Urrutia, P. Delheij [1], G. Gwinner [4], A. Lapierre [1,7], D. Lunney [1,9], M. R. Pearson [1], R. Ringle [7], J. Ullrich [5], J. Dilling [1,2]

Abstract

Penning trap mass measurements of short-lived nuclides have been performed for the first time with highly-charged ions (HCI), using the TITAN facility at TRIUMF. Compared to singly-charged ions, this provides an improvement in experimental precision that scales with the charge state q. Neutron-deficient Rb-isotopes have been charge bred in an electron beam ion trap to q = 8 - 12+ prior to injection into the Penning trap. In combination with the Ramsey excitation scheme, this unique setup creating low energy, highly-charged ions at a radioactive beam facility opens the door to unrivalled precision with gains of 1-2 orders of magnitude. The method is particularly suited for short-lived nuclides such as the superallowed β emitter 74Rb (T1/2 = 65 ms). The determination of its atomic mass and an improved QEC-value are presented.

TITAN's Digital RFQ Ion Beam Cooler and Buncher, Operation and Performance

T. Brunner [1], M. J. Smith, M. Brodeur [1], S. Ettenauer [1], A. T. Gallant, V. V. Simon, A. Chaudhuri A. Lapierre, E. Mané, R. Ringle, M. C. Simon, J. A. Vaz, P. Delheij, M. Good, M. R. Pearson, J. Dilling [2]

Abstract

We present a description of the Radio Frequency Quadrupole (RFQ) ion trap built as part of the TITAN facility. It consists of a gas-filled, segmented, linear Paul trap and is the first stage of the TITAN setup with the purpose of cooling and bunching radioactive ion beams delivered from ISAC-TRIUMF. This is the first such device to be driven digitally, i.e., using a high voltage ($V_{pp} = \rm{400 \, V}$), wide bandwidth ($0.2 < f < 1.2 \, \rm{MHz}$) square-wave as compared to the typical sinusoidal wave form. Results from the commissioning of the device as well as systematic studies with stable and radioactive ions are presented including efficiency measurements with stable $^{133}$Cs and radioactive $^{124, 126}$Cs. A novel and unique mode of operation of this device is also demonstrated where the cooled ion bunches are extracted in reverse mode, i.e., in the same direction as previously injected.