A. M. Houff

Offline Commissioning of the St. Benedict Gas Catcher

F. Rivero, D. Guillet, M. Brodeur, J. A. Clark, A. M. Houff, J. J. Kolata, B. Liu, J. McRae, P. D. O'Malley, W. S. Porter, C. Quick, G. Savard [1], A. A. Valverde, R. Zite [1]

Abstract

Precision measurements of $β$ decay transitions offer a promising channel through which the Standard Model (SM) can be probed. There is currently an ongoing effort to increase the precision on measurements of $\mathcal{F}t$-values for superallowed $β$ decay transitions between mirror nuclides. These allow for a determination of $V_{ud}$ which is complementary to that obtained from pure Fermi $0^+ \rightarrow 0^+$ transitions. The Superallowed Transition BEta-NEutrino Decay Ion Coincidence Trap (St. Benedict), under construction at the Nuclear Science Laboratory (NSL) at the University of Notre Dame, seeks to measure the Fermi-to-Gamow-Teller mixing ratio for transitions between mirror nuclei in order to expand the list of nuclides from which $V_{ud}$ can be extracted. Production and selection of the species of interest will be done in-flight, using the \textit{TwinSol} magnetic separator system. The first element of St. Benedict will be a large volume gas catcher which will thermalize radioactive ion beams for low energy delivery to the rest of the system. Offline commissioning of this gas catcher has been completed using an internal potassium source, and the device demonstrated a transport efficiency upwards of 95\% for pressures of 66 mbar and lower.

Precision Mass Measurements of \textsuperscript{130}Te, \textsuperscript{130}Sn, and Their Impact on Models for R-Process Nucleosynthesis

A. Cannon, W. S. Porter, A. A. Valverde, D. P. Burdette, A. M. Houff, B. Liu, A. Mitra, G. E. Morgan, C. Quick [1], D. Ray [1], L. Varriano [1], M. Brodeur [1], J. A. Clark, G. Savard [1], G. J. Mathews

Abstract

The astrophysical rapid neutron capture nucleosynthesis process (r-process) remains an active area of research due to the fact that it occurs in extreme conditions and involves reactions with exotic nuclei that are difficult to study experimentally. For the first time using the Phase-Imaging Ion Cyclotron Resonance (PI-ICR) technique, we measured the mass excesses of \textsuperscript{130}Te, \textsuperscript{130}Sn, and \textsuperscript{130}Sn\textsuperscript{m} with the Canadian Penning Trap (CPT). Our results show good agreement with previous Penning trap values obtained using the Time-of-Flight Ion Cyclotron Resonance (TOF-ICR) and the Fourier Transform Ion Cyclotron Resonance (FT-ICR) techniques, while being twice as precise for \textsuperscript{130}Sn. These new mass excesses were added to a SkyNet network calculation to determine their impact on r-process abundances and to find the best astrophysical conditions to reproduce the Solar System r-process abundance pattern. Finally, by treating lighter and heavier elements separately, we assess the relative frequency of events producing elements in a cold versus a hot r-process scenario.

Precise Mass Measurement of the $^{149}$La-$^{149}$Ce-$^{149}$Pr isobaric chain

B. Liu [1,2], M. Brodeur [1,2], J. A. Clark, D. Ray [3,2], G. Savard [2,4,3,1], A. A. Valverde, D. P. Burdette, A. M. Houff, A. Mitra [1,5,2], G. E. Morgan, R. Orford [6,1], W. S. Porter, C. Quick [1], F. Rivero [1,3], K. S. Sharma, L. Varriano [4,2]

Abstract

Penning trap mass measurements of $^{149}$La, $^{149}$Ce, and $^{149}$Pr were performed with the Canadian Penning Trap (CPT) at the CARIBU facility of Argonne National Laboratory using the phase-imaging ion-cyclotron-resonance technique. The resulting mass excess of $^{149}$La differs by 221 keV from a recent JYFLTRAP measurement, resulting in a significant change in the profile of the two-neutron separation energy for that isotopic chain. The mass excesses of $^{149}$Ce and $^{149}$Pr are determined with an eight-fold improvement in precision compared to previous time-of-flight ion-cyclotron-resonance measurements; the $^{149}$Ce value is consistent with AME2020, while the $^{149}$Pr mass excess is lower by 17.5 keV. The mass excesses of $^{149}$La and $^{149}$Pr reported in this work have been confirmed recently by a measurement with a multi-reflection time-of-flight mass spectrometer coupled to a $β$-time of flight detector at RIKEN, providing further validation of the present results.

Off-line Commissioning of the St. Benedict Radiofrequency Quadrupole Cooler-Buncher

D. P. Burdette, R. Zite, M. Brodeur, A. A. Valverde, O. Bruce, R. Bualuan, A. Cannon, J. A. Clark, C. Davis, T. Florenzo, A. T. Gallant, J. Harkin, A. M. Houff, J. Li, B. Liu, J. Long, P. D. O'Malley, W. S. Porter, C. Quick [1], R. Ringle [1], F. Rivero [1], G. Savard [1], M. A. Yeck

Abstract

The St. Benedict ion trapping system, which aims to measure the $β-ν$ angular correlation parameter in superallowed-mixed mirror transitions, is under construction at the University of Notre Dame. These measurements will provide much-needed data to improve the accuracy of the $V_{ud}$ element of the CKM matrix. One of the major components of this system is the radio frequency quadrupole cooler-buncher, which is necessary to create low-emittance ion bunches for injection into the measurement Paul trap. The off-line commissioning of the cooler-buncher, using a potassium ion source, determined that the device could produce cooled ion bunches characterized by a 50-ns full-width-half-maximum time width. The commissioning results also determined the trapping efficiency to be 93(1)$\%$ and the trapping half-life to be 20.0(5) s.

Astrophysical significance of the isomer $^{119m}$Ag demonstrated through direct mass measurement

F. Rivero [1], M. Brodeur [1,2], J. A. Clark, B. Liu [1,2,3,4], G. W. Misch, M. R. Mumpower, W. S. Porter, D. Ray [5,2], G. Savard [2,6,3,5], T. M. Sprouse, A. A. Valverde, D. P. Burdette, A. Cannon [7,8,1], A. T. Gallant, A. M. Houff, K. Kolos [8,2], F. G. Kondev, R. Orford [9], C. Quick [1,5], K. S. Sharma, L. Varriano [10]

Abstract

The abundance of elements heavier than iron produced via the astrophysical rapid-neutron capture process depends sensitively on the atomic mass of the involved nuclei as well as the behavior of a few special types of nuclear isomers called astromers. High-precision mass measurements of $^{119}$Cd, $^{119}$Ag and their respective isomeric states have been performed with the Phase Imaging-Ion Cyclotron Resonance (PI-ICR) method with a precision of $δm/m \approx 10^{-8}$ using the Canadian Penning Trap (CPT). The ground state mass excess, as well as the excitation energy, agrees with recent Penning Trap measurements from JYFLTRAP. Network calculations using these new measurements revealed that, contrary to previous expectations, $^{119m}$Ag behaves as an astromer which significantly affects the population of $^{119}$Ag.