A. T. Gallant

Off-line Commissioning of the St. Benedict Radiofrequency Quadrupole Cooler-Buncher

D. P. Burdette, R. Zite, M. Brodeur, A. A. Valverde, O. Bruce, R. Bualuan, A. Cannon, J. A. Clark, C. Davis, T. Florenzo, A. T. Gallant, J. Harkin, A. M. Houff, J. Li, B. Liu, J. Long, P. D. O'Malley, W. S. Porter, C. Quick [1], R. Ringle [1], F. Rivero [1], G. Savard [1], M. A. Yeck

Abstract

The St. Benedict ion trapping system, which aims to measure the $β-ν$ angular correlation parameter in superallowed-mixed mirror transitions, is under construction at the University of Notre Dame. These measurements will provide much-needed data to improve the accuracy of the $V_{ud}$ element of the CKM matrix. One of the major components of this system is the radio frequency quadrupole cooler-buncher, which is necessary to create low-emittance ion bunches for injection into the measurement Paul trap. The off-line commissioning of the cooler-buncher, using a potassium ion source, determined that the device could produce cooled ion bunches characterized by a 50-ns full-width-half-maximum time width. The commissioning results also determined the trapping efficiency to be 93(1)$\%$ and the trapping half-life to be 20.0(5) s.

Improved Limit on Tensor Currents in the Weak Interaction from $^8$Li $β$ Decay

M. T. Burkey [1,2,3], G. Savard [2,3], A. T. Gallant [1], N. D. Scielzo [1,3,4], T. Y. Hirsh [4,3,5], L. Varriano [2,3], G. H. Sargsyan [6], K. D. Launey [6], M. Brodeur [7], D. P. Burdette [7,3], E. Heckmaier [8,1], K. Joerres [6], J. W. Klimes [3], K. Kolos [1], A. Laminack [6], K. G. Leach [9], A. F. Levand [3], B. Longfellow [1,10,3], B. Maaß, S. T. Marley [6], G. E. Morgan [6], P. Mueller [3], R. Orford [3,11], S. W. Padgett [1,3], A. Pérez Galván, J. R. Pierce [2,3], D. Ray [4,3], R. Segel [12], K. Siegl [7], K. S. Sharma [4], B. S. Wang [1]

Abstract

The electroweak interaction in the Standard Model (SM) is described by a pure vector-axial-vector structure, though any Lorentz-invariant component could contribute. In this work, we present the most precise measurement of tensor currents in the low-energy regime by examining the $β$-$\barν$ correlation of trapped $^{8}$Li ions with the Beta-decay Paul Trap. We find $a_{βν} = -0.3325 \pm 0.0013_{stat} \pm 0.0019_{syst}$ at $1σ$ for the case of coupling to right-handed neutrinos $(C_T=-C_T')$, which is consistent with the SM prediction.

Improvements to TITAN's Mass Measurement and Decay Spectroscopy Capabilities

D. Lascar, A. A. Kwiatkowski, M. Alanssari, U. Chowdhury, J. Even, A. Finlay, A. T. Gallant, M. Good, R. Klawitter, B. Kootte, T. Li K. G. Leach, A. Lennarz, E. Leistenschneider, A. J. Mayer, B. E. Schultz, R. Schupp [1], D. A. Short, C. Andreoiu [1], J. Dilling [1], G. Gwinner [1]

Abstract

The study of nuclei farther from the valley of $β$-stability goes hand-in-hand with shorter-lived nuclei produced in smaller abundances than their more stable counterparts. The measurement, to high precision, of nuclear masses therefore requires innovations in technique in order to keep up. TRIUMF's Ion Trap for Atomic and Nuclear science (TITAN) facility deploys three ion traps, with a fourth in the commissioning phase, to perform and support Penning trap mass spectrometry and in-trap decay spectroscopy on some of the shortest-lived nuclei ever studied. We report on recent advances and updates to the TITAN facility since the 2012 EMIS Conference. TITAN's charge breeding capabilities have been improved and in-trap decay spectroscopy can be performed in TITAN's electron beam ion trap (EBIT). Higher charge states can improve the precision of mass measurements, reduce the beam-time requirements for a given measurement, improve beam purity and opens the door to access, via in-trap decay and recapture, isotopes not available from the ISOL method. This was recently demonstrated during TITAN's mass measurement of $^{30}$Al. The EBIT's decay spectroscopy setup was commissioned with a successful branching ratio and half-life measurement of $^{124}$Cs. Charge breeding in the EBIT increases the energy spread of the ion bunch sent to the Penning trap for mass measurement so a new Cooler Penning Trap (CPET), which aims to cool highly charge ions with an electron plasma, is undergoing online commissioning. Already, CPET has demonstrated the trapping and self-cooling of a room-temperature electron plasma which was stored for several minutes. A new detector has been installed inside the CPET magnetic field which will allow for in-magnet charged particle detection.

Trapped-ion decay spectroscopy towards the determination of ground-state components of double-beta decay matrix elements

T. Brunner [1,2], A. Lapierre [1], C. Andreoiu [3], M. Brodeur [4], P. Delheji [1], S. Ettenauer [1,5], D. Frekers [6,1,5,2], A. T. Gallant, R. Gernhäuser, A. Grossheim [1,2], R. Krücken, A. Lennarz [1,6], D. Lunney [7,2], D. Mücher, R. Ringle [1,8,9], M. C. Simon, V. V. Simon, S. K. L. Sjue, K. Zuber [10], J. Dilling [1,5]

Abstract

A new technique has been developed at TRIUMF's TITAN facility to perform in-trap decay spectroscopy. The aim of this technique is to eventually measure weak electron capture branching ratios (ECBRs) and by this to consequently determine GT matrix elements of $ββ$ decaying nuclei. These branching ratios provide important input to the theoretical description of these decays. The feasibility and power of the technique is demonstrated by measuring the ECBR of $^{124}$Cs.

Verifying the accuracy of the TITAN Penning-trap mass spectrometer

M. Brodeur [1,2], V. L. Ryjkov, T. Brunner [1,3], S. Ettenauer [1,2], A. T. Gallant [1,2,4,5], V. V. Simon, M. J. Smith, A. Lapierre [1], R. Ringle [1], P. Delheij [1], M. Good [1], D. Lunney [6], J. Dilling [1,2]

Abstract

TITAN (TRIUMF's Ion Traps for Atomic and Nuclear science) is an online facility designed to carry out high-precision mass measurements on singly and highly charged radioactive ions. The TITAN Penning trap has been built and optimized in order to perform such measurements with an accuracy in the sub ppb-range. A detailed characterization of the TITAN Penning trap is presented and a new compensation method is derived and demonstrated, verifying the performance in the range of sub-ppb.

First Use of High Charge States for Mass Measurements of Short-lived Nuclides in a Penning Trap

S. Ettenauer [1,2], M. C. Simon [1], A. T. Gallant [1,2], T. Brunner [1,3], U. Chowdhury [1,4], V. V. Simon [1,5,6], M. Brodeur [1,2,7], A. Chaudhuri [1], E. Mané, C. Andreoiu [8], G. Audi [9,5], J. R. Crespo López-Urrutia, P. Delheij [1], G. Gwinner [4], A. Lapierre [1,7], D. Lunney [1,9], M. R. Pearson [1], R. Ringle [7], J. Ullrich [5], J. Dilling [1,2]

Abstract

Penning trap mass measurements of short-lived nuclides have been performed for the first time with highly-charged ions (HCI), using the TITAN facility at TRIUMF. Compared to singly-charged ions, this provides an improvement in experimental precision that scales with the charge state q. Neutron-deficient Rb-isotopes have been charge bred in an electron beam ion trap to q = 8 - 12+ prior to injection into the Penning trap. In combination with the Ramsey excitation scheme, this unique setup creating low energy, highly-charged ions at a radioactive beam facility opens the door to unrivalled precision with gains of 1-2 orders of magnitude. The method is particularly suited for short-lived nuclides such as the superallowed β emitter 74Rb (T1/2 = 65 ms). The determination of its atomic mass and an improved QEC-value are presented.

TITAN's Digital RFQ Ion Beam Cooler and Buncher, Operation and Performance

T. Brunner [1], M. J. Smith, M. Brodeur [1], S. Ettenauer [1], A. T. Gallant, V. V. Simon, A. Chaudhuri A. Lapierre, E. Mané, R. Ringle, M. C. Simon, J. A. Vaz, P. Delheij, M. Good, M. R. Pearson, J. Dilling [2]

Abstract

We present a description of the Radio Frequency Quadrupole (RFQ) ion trap built as part of the TITAN facility. It consists of a gas-filled, segmented, linear Paul trap and is the first stage of the TITAN setup with the purpose of cooling and bunching radioactive ion beams delivered from ISAC-TRIUMF. This is the first such device to be driven digitally, i.e., using a high voltage ($V_{pp} = \rm{400 \, V}$), wide bandwidth ($0.2 < f < 1.2 \, \rm{MHz}$) square-wave as compared to the typical sinusoidal wave form. Results from the commissioning of the device as well as systematic studies with stable and radioactive ions are presented including efficiency measurements with stable $^{133}$Cs and radioactive $^{124, 126}$Cs. A novel and unique mode of operation of this device is also demonstrated where the cooled ion bunches are extracted in reverse mode, i.e., in the same direction as previously injected.