A. T. Gallant

Off-line Commissioning of the St. Benedict Radiofrequency Quadrupole Cooler-Buncher

D. P. Burdette, R. Zite, M. Brodeur, A. A. Valverde, O. Bruce, R. Bualuan, A. Cannon, J. A. Clark, C. Davis, T. Florenzo, A. T. Gallant, J. Harkin, A. M. Houff, J. Li, B. Liu, J. Long, P. D. O'Malley, W. S. Porter, C. Quick [1], R. Ringle [1], F. Rivero [1], G. Savard [1], M. A. Yeck

Abstract

The St. Benedict ion trapping system, which aims to measure the $β-ν$ angular correlation parameter in superallowed-mixed mirror transitions, is under construction at the University of Notre Dame. These measurements will provide much-needed data to improve the accuracy of the $V_{ud}$ element of the CKM matrix. One of the major components of this system is the radio frequency quadrupole cooler-buncher, which is necessary to create low-emittance ion bunches for injection into the measurement Paul trap. The off-line commissioning of the cooler-buncher, using a potassium ion source, determined that the device could produce cooled ion bunches characterized by a 50-ns full-width-half-maximum time width. The commissioning results also determined the trapping efficiency to be 93(1)$\%$ and the trapping half-life to be 20.0(5) s.

Astrophysical significance of the isomer $^{119m}$Ag demonstrated through direct mass measurement

F. Rivero [1], M. Brodeur [1,2], J. A. Clark, B. Liu [1,2,3,4], G. W. Misch, M. R. Mumpower, W. S. Porter, D. Ray [5,2], G. Savard [2,6,3,5], T. M. Sprouse, A. A. Valverde, D. P. Burdette, A. Cannon [7,8,1], A. T. Gallant, A. M. Houff, K. Kolos [8,2], F. G. Kondev, R. Orford [9], C. Quick [1,5], K. S. Sharma, L. Varriano [10]

Abstract

The abundance of elements heavier than iron produced via the astrophysical rapid-neutron capture process depends sensitively on the atomic mass of the involved nuclei as well as the behavior of a few special types of nuclear isomers called astromers. High-precision mass measurements of $^{119}$Cd, $^{119}$Ag and their respective isomeric states have been performed with the Phase Imaging-Ion Cyclotron Resonance (PI-ICR) method with a precision of $δm/m \approx 10^{-8}$ using the Canadian Penning Trap (CPT). The ground state mass excess, as well as the excitation energy, agrees with recent Penning Trap measurements from JYFLTRAP. Network calculations using these new measurements revealed that, contrary to previous expectations, $^{119m}$Ag behaves as an astromer which significantly affects the population of $^{119}$Ag.

Mass measurements of neutron-rich nuclides using the Canadian Penning Trap to inform predictions in the $r$-process rare-earth peak region

D. Ray [1,2], N. Vassh [3], B. Liu [4,2,1], A. A. Valverde, M. Brodeur [4,2,1,5,6], J. A. Clark, G. C. McLaughlin, M. R. Mumpower, R. Orford [7,4], W. S. Porter, G. Savard [2,8], K. S. Sharma [1], R. Surman [4], F. Buchinger [9,2], D. P. Burdette, N. Callahan [2,10], A. T. Gallant, D. E. M. Hoff, K. Kolos [10,2], F. G. Kondev, G. E. Morgan [2,11], F. Rivero [4], D. Santiago-Gonzalez [2,10], N. D. Scielzo, L. Varriano [2,8,12], C. M. Weber, G. E. Wilson [11,2,13], X. L. Yan

Abstract

Studies aiming to determine the astrophysical origins of nuclei produced by the rapid neutron capture process ($r$ process) rely on nuclear properties as inputs for simulations. The solar abundances can be used as a benchmark for such calculations, with the $r$-process rare-earth peak (REP) around mass number ($A$) 164 being of special interest due to its presently unknown origin. With the advancement of rare isotope beam production over the last decade and improvement in experimental sensitivities, many of these REP nuclides have become accessible for measurement. Masses are one of the most critical inputs as they impact multiple nuclear properties, namely the neutron-separation energies, neutron capture rates, $β$-decay rates, and $β$-delayed neutron emission probabilities. In this work, we report masses of 20 neutron-rich nuclides (along the Ba, La, Ce, Pr, Nd, Pm, Gd, Dy and Ho isotopic chains) produced at the CAlifornium Rare Isotope Breeder Upgrade (CARIBU) facility at Argonne National Laboratory. The masses were measured with the Canadian Penning trap (CPT) mass spectrometer using the Phase-Imaging Ion-Cyclotron-Resonance (PI-ICR) technique. We then use these new masses along with previously published CPT masses to inform predictions for a Markov Chain Monte Carlo (MCMC) procedure aiming to identify the astrophysical conditions consistent with both solar data and mass measurements. We show that the MCMC responds to this updated mass information, producing refined results for both mass predictions and REP abundances.

Improved Limit on Tensor Currents in the Weak Interaction from $^8$Li $β$ Decay

M. T. Burkey [1,2,3], G. Savard [2,3], A. T. Gallant [1], N. D. Scielzo [1,3,4], T. Y. Hirsh [4,3,5], L. Varriano [2,3], G. H. Sargsyan [6], K. D. Launey [6], M. Brodeur [7], D. P. Burdette [7,3], E. Heckmaier [8,1], K. Joerres [6], J. W. Klimes [3], K. Kolos [1], A. Laminack [6], K. G. Leach [9], A. F. Levand [3], B. Longfellow [1,10,3], B. Maaß, S. T. Marley [6], G. E. Morgan [6], P. Mueller [3], R. Orford [3,11], S. W. Padgett [1,3], A. Pérez Galván, J. R. Pierce [2,3], D. Ray [4,3], R. Segel [12], K. Siegl [7], K. S. Sharma [4], B. S. Wang [1]

Abstract

The electroweak interaction in the Standard Model (SM) is described by a pure vector-axial-vector structure, though any Lorentz-invariant component could contribute. In this work, we present the most precise measurement of tensor currents in the low-energy regime by examining the $β$-$\barν$ correlation of trapped $^{8}$Li ions with the Beta-decay Paul Trap. We find $a_{βν} = -0.3325 \pm 0.0013_{stat} \pm 0.0019_{syst}$ at $1σ$ for the case of coupling to right-handed neutrinos $(C_T=-C_T')$, which is consistent with the SM prediction.

High-precision $Q_{EC}$-value measurement of the superallowed $β^+$ emitter $^{22}$Mg and an evaluation of the $A=22$ isobaric triplet

M. P. Reiter, K. G. Leach, O. M. Drozdowski [1,4], S. R. Stroberg, J. D. Holt, C. Andreoiu [5], C. Babcock [1], B. Barquest [1], M. Brodeur [6], A. Finlay [7,1], M. Foster [8,1,7,9], A. T. Gallant, G. Gwinner [10], R. Klawitter [1,11], B. Kootte [7,1,12], A. A Kwiatkowski, Y. Lan [7,1], D. Lascar [1], E. Leistenschneider [7,1], A. Lennarz [1,13], S. Paul [1,12,14], R. Steinbrügge, R. I. Thompson, M. Wieser [14], J. Dilling [1,7]

Abstract

A direct $Q_{EC}$-value measurement of the superallowed $β^+$ emitter $^{22}$Mg was performed using TRIUMF's Ion Trap for Atomic and Nuclear science (TITAN). The direct ground-state to ground-state atomic mass difference between $^{22}$Mg and $^{22}$Na was determined to be $Q_{EC}=4781.40(22)$~keV, representing the most precise single measurement of this quantity to date. In a continued push towards calculating superallowed isospin-symmetry-breaking (ISB) corrections from first principles, ab-initio shell-model calculations of the $A=22$ IMME are also presented for the first time using the valence-space in-medium similarity renormalization group formalism. With particular starting two- and three-nucleon forces, this approach demonstrates a level of agreement with the experimental data that suggests reliable ab-initio calculations of superallowed ISB corrections are now possible.

Improvements to TITAN's Mass Measurement and Decay Spectroscopy Capabilities

D. Lascar, A. A. Kwiatkowski, M. Alanssari, U. Chowdhury, J. Even, A. Finlay, A. T. Gallant, M. Good, R. Klawitter, B. Kootte, T. Li K. G. Leach, A. Lennarz, E. Leistenschneider, A. J. Mayer, B. E. Schultz, R. Schupp [1], D. A. Short, C. Andreoiu [1], J. Dilling [1], G. Gwinner [1]

Abstract

The study of nuclei farther from the valley of $β$-stability goes hand-in-hand with shorter-lived nuclei produced in smaller abundances than their more stable counterparts. The measurement, to high precision, of nuclear masses therefore requires innovations in technique in order to keep up. TRIUMF's Ion Trap for Atomic and Nuclear science (TITAN) facility deploys three ion traps, with a fourth in the commissioning phase, to perform and support Penning trap mass spectrometry and in-trap decay spectroscopy on some of the shortest-lived nuclei ever studied. We report on recent advances and updates to the TITAN facility since the 2012 EMIS Conference. TITAN's charge breeding capabilities have been improved and in-trap decay spectroscopy can be performed in TITAN's electron beam ion trap (EBIT). Higher charge states can improve the precision of mass measurements, reduce the beam-time requirements for a given measurement, improve beam purity and opens the door to access, via in-trap decay and recapture, isotopes not available from the ISOL method. This was recently demonstrated during TITAN's mass measurement of $^{30}$Al. The EBIT's decay spectroscopy setup was commissioned with a successful branching ratio and half-life measurement of $^{124}$Cs. Charge breeding in the EBIT increases the energy spread of the ion bunch sent to the Penning trap for mass measurement so a new Cooler Penning Trap (CPET), which aims to cool highly charge ions with an electron plasma, is undergoing online commissioning. Already, CPET has demonstrated the trapping and self-cooling of a room-temperature electron plasma which was stored for several minutes. A new detector has been installed inside the CPET magnetic field which will allow for in-magnet charged particle detection.

Low-Background In-Trap Decay Spectroscopy with TITAN at TRIUMF

K. G. Leach, A. Lennarz [1,3], A. Grossheim [1], R. Klawitter [1,4], T. Brunner [1,5], A. Chaudhuri [1], U. Chowdhury [1,6,4,7], J. R. Crespo López-Urrutia, A. T. Gallant, A. A. Kwiatkowski, T. D. Macdonald, B. E. Schultz, S. Seeraji [2], C. Andreoiu [2], D. Frekers [3], J. Dilling [1]

Abstract

An in-trap decay spectroscopy setup has been developed and constructed for use with the TITAN facility at TRIUMF. The goal of this device is to observe weak electron-capture (EC) branching ratios for the odd-odd intermediate nuclei in the $ββ$ decay process. This apparatus consists of an up-to 6 Tesla, open-access spectroscopy ion-trap, surrounded radially by up to 7 planar Si(Li) detectors which are separated from the trap by thin Be windows. This configuration provides a significant increase in sensitivity for the detection of low-energy photons by providing backing-free ion storage and eliminating charged-particle-induced backgrounds. An intense electron beam is also employed to increase the charge-states of the trapped ions, thus providing storage times on the order of minutes, allowing for decay-spectroscopy measurements. The technique of multiple ion-bunch stacking was also recently demonstrated, which further extends the measurement possibilities of this apparatus. The current status of the facility and initial results from a $^{116}$In measurement are presented.

The TITAN in-trap decay spectroscopy facility at TRIUMF

K. G. Leach, A. Grossheim, A. Lennarz, T. Brunner, J. R. Crespo López-Urrutia, A. T. Gallant, M. Good, R. Klawitter, A. A. Kwiatkowski, T. Ma, T. D. Macdonald, S. Seeraji, M. C. Simon, C. Andreoiu, J. Dilling [1], D. Frekers [1]

Abstract

This article presents an upgraded in-trap decay spectroscopy apparatus which has been developed and constructed for use with TRIUMF's Ion Trap for Atomic and Nuclear science (TITAN). This device consists of an open-access electron-beam ion-trap (EBIT), which is surrounded radially by seven low-energy planar Si(Li) detectors. The environment of the EBIT allows for the detection of low-energy photons by providing backing-free storage of the radioactive ions, while guiding charged decay particles away from the trap centre via the strong (up to 6 T) magnetic field. In addition to excellent ion confinement and storage, the EBIT also provides a venue for performing decay spectroscopy on highly-charged radioactive ions. Recent technical advancements have been able to provide a significant increase in sensitivity for low-energy photon detection, towards the goal of measuring weak electron-capture branching ratios of the intermediate nuclei in the two-neutrino double beta ($2νββ$) decay process. The design, development, and commissioning of this apparatus are presented together with the main physics objectives. The future of the device and experimental technique are discussed.

Trapped-ion decay spectroscopy towards the determination of ground-state components of double-beta decay matrix elements

T. Brunner [1,2], A. Lapierre [1], C. Andreoiu [3], M. Brodeur [4], P. Delheji [1], S. Ettenauer [1,5], D. Frekers [6,1,5,2], A. T. Gallant, R. Gernhäuser, A. Grossheim [1,2], R. Krücken, A. Lennarz [1,6], D. Lunney [7,2], D. Mücher, R. Ringle [1,8,9], M. C. Simon, V. V. Simon, S. K. L. Sjue, K. Zuber [10], J. Dilling [1,5]

Abstract

A new technique has been developed at TRIUMF's TITAN facility to perform in-trap decay spectroscopy. The aim of this technique is to eventually measure weak electron capture branching ratios (ECBRs) and by this to consequently determine GT matrix elements of $ββ$ decaying nuclei. These branching ratios provide important input to the theoretical description of these decays. The feasibility and power of the technique is demonstrated by measuring the ECBR of $^{124}$Cs.

Highly charged ions in Penning traps, a new tool for resolving low lying isomeric states

A. T. Gallant, M. Brodeur [1,2,3], T. Brunner [1,4], U. Chowdhury [1,5], S. Ettenauer [1,2,6,7], V. V. Simon, E. Mané, M. C. Simon, C. Andreoiu [8], P. Delheij [1], G. Gwinner [5], M. R. Pearson [1], R. Ringle [3], J. Dilling [1,2]

Abstract

The use of highly charged ions increases the precision and resolving power, in particular for short-lived species produced at on-line radio-isotope beam facilities, achievable with Penning trap mass spectrometers. This increase in resolving power provides a new and unique access to resolving low-lying long-lived ($T_{1/2} > 50$ ms) nuclear isomers. Recently, the $111.19(22)$ keV (determined from $γ$-ray spectroscopy) isomeric state in $^{78}$Rb has been resolved from the ground state, in a charge state of $q=8+$ with the TITAN Penning trap at the TRIUMF-ISAC facility. The excitation energy of the isomer was measured to be $108.7(6.4)$ keV above the ground state. The extracted masses for both the ground and isomeric states, and their difference, agree with the AME2003 and Nuclear Data Sheet values. This proof of principle measurement demonstrates the feasibility of using Penning trap mass spectrometers coupled to charge breeders to study nuclear isomers and opens a new route for isomer searches.

Verifying the accuracy of the TITAN Penning-trap mass spectrometer

M. Brodeur [1,2], V. L. Ryjkov, T. Brunner [1,3], S. Ettenauer [1,2], A. T. Gallant [1,2,4,5], V. V. Simon, M. J. Smith, A. Lapierre [1], R. Ringle [1], P. Delheij [1], M. Good [1], D. Lunney [6], J. Dilling [1,2]

Abstract

TITAN (TRIUMF's Ion Traps for Atomic and Nuclear science) is an online facility designed to carry out high-precision mass measurements on singly and highly charged radioactive ions. The TITAN Penning trap has been built and optimized in order to perform such measurements with an accuracy in the sub ppb-range. A detailed characterization of the TITAN Penning trap is presented and a new compensation method is derived and demonstrated, verifying the performance in the range of sub-ppb.

First Use of High Charge States for Mass Measurements of Short-lived Nuclides in a Penning Trap

S. Ettenauer [1,2], M. C. Simon [1], A. T. Gallant [1,2], T. Brunner [1,3], U. Chowdhury [1,4], V. V. Simon [1,5,6], M. Brodeur [1,2,7], A. Chaudhuri [1], E. Mané, C. Andreoiu [8], G. Audi [9,5], J. R. Crespo López-Urrutia, P. Delheij [1], G. Gwinner [4], A. Lapierre [1,7], D. Lunney [1,9], M. R. Pearson [1], R. Ringle [7], J. Ullrich [5], J. Dilling [1,2]

Abstract

Penning trap mass measurements of short-lived nuclides have been performed for the first time with highly-charged ions (HCI), using the TITAN facility at TRIUMF. Compared to singly-charged ions, this provides an improvement in experimental precision that scales with the charge state q. Neutron-deficient Rb-isotopes have been charge bred in an electron beam ion trap to q = 8 - 12+ prior to injection into the Penning trap. In combination with the Ramsey excitation scheme, this unique setup creating low energy, highly-charged ions at a radioactive beam facility opens the door to unrivalled precision with gains of 1-2 orders of magnitude. The method is particularly suited for short-lived nuclides such as the superallowed β emitter 74Rb (T1/2 = 65 ms). The determination of its atomic mass and an improved QEC-value are presented.

A large Bradbury Nielsen ion gate with flexible wire spacing based on photo-etched stainless steel grids and its characterization applying symmetric and asymmetric potentials

T. Brunner, A. R. Mueller, K. O'Sullivan, M. C. Simon, M. Kossick, S. Ettenauer, A. T. Gallant, E. Mané, D. Bishop, M. Good, G. Gratta [1], J. Dilling [1]

Abstract

Bradbury Nielsen gates are well known devices used to switch ion beams and are typically applied in mass or mobility spectrometers for separating beam constituents by their different flight or drift times. A Bradbury Nielsen gate consists of two interleaved sets of electrodes. If two voltages of the same amplitude but opposite polarity are applied the gate is closed, and for identical (zero) potential the gate is open. Whereas former realizations of the device employ actual wires resulting in difficulties with winding, fixing and tensioning them, our approach is to use two grids photo-etched from a metallic foil. This design allows for simplified construction of gates covering large beam sizes up to at least 900\,mm$^2$ with variable wire spacing down to 250\,\textmu m. By changing the grids the wire spacing can be varied easily. A gate of this design was installed and systematically tested at TRIUMF's ion trap facility, TITAN, for use with radioactive beams to separate ions with different mass-to-charge ratios by their time-of-flight.

TITAN's Digital RFQ Ion Beam Cooler and Buncher, Operation and Performance

T. Brunner [1], M. J. Smith, M. Brodeur [1], S. Ettenauer [1], A. T. Gallant, V. V. Simon, A. Chaudhuri A. Lapierre, E. Mané, R. Ringle, M. C. Simon, J. A. Vaz, P. Delheij, M. Good, M. R. Pearson, J. Dilling [2]

Abstract

We present a description of the Radio Frequency Quadrupole (RFQ) ion trap built as part of the TITAN facility. It consists of a gas-filled, segmented, linear Paul trap and is the first stage of the TITAN setup with the purpose of cooling and bunching radioactive ion beams delivered from ISAC-TRIUMF. This is the first such device to be driven digitally, i.e., using a high voltage ($V_{pp} = \rm{400 \, V}$), wide bandwidth ($0.2 < f < 1.2 \, \rm{MHz}$) square-wave as compared to the typical sinusoidal wave form. Results from the commissioning of the device as well as systematic studies with stable and radioactive ions are presented including efficiency measurements with stable $^{133}$Cs and radioactive $^{124, 126}$Cs. A novel and unique mode of operation of this device is also demonstrated where the cooled ion bunches are extracted in reverse mode, i.e., in the same direction as previously injected.