M. R. Pearson

Bi-Arrhenius diffusion and surface trapping of $^{8}$Li$^{+}$ in rutile TiO$_2$

A. Chatzichristos, R. M. L. McFadden, M. H. Dehn, S. R. Dunsiger, D. Fujimoto, V. L. Karner, I. McKenzie, G. D. Morris [1], M. R. Pearson [1], M. Stachura [1], J. Sugiyama [1], J. O. Ticknor [1], W. A. MacFarlane [1], R. F. Kiefl [1]

Abstract

We report measurements of the diffusion rate of isolated ion-implanted $^{8}$Li$^{+}$ within $\sim$120 nm of the surface of oriented single-crystal rutile TiO$_2$ using a radiotracer technique. The $α$-particles from the $^{8}$Li decay provide a sensitive monitor of the distance from the surface and how the depth profile of $^{8}$Li evolves with time. The main findings are that the implanted Li$^{+}$ diffuses and traps at the (001) surface. The T-dependence of the diffusivity is described by a bi-Arrhenius expression with activation energies of 0.3341(21) eV above 200 K, whereas at lower temperatures it has a much smaller barrier of 0.0313(15) eV. We consider possible origins for the surface trapping, as well the nature of the low-T barrier.

Offline trapping of $^{221}$Fr in a magneto-optical trap from implantation of an $^{225}$Ac ion beam

M. Tandecki, J. Zhang, S. Aubin, J. A. Behr, R. Collister, E. Gomez, G. Gwinner [1], H. Heggen [1], J. Lassen [1], L. A. Orozco [1], M. R. Pearson [1], S. Raeder [1], A. Teigelhöfer

Abstract

We demonstrate a new technique to prepare an offline source of francium for trapping in a magneto-optical trap. Implanting a radioactive beam of $^{225}$Ac, $t_{1/2} = 9.920(3)$ days, in a foil, allows use of the decay products, i.e.$^{221}$Fr, $t_{1/2} = 288.0(4)$ s. $^{221}$Fr is ejected from the foil by the $α$ decay of $^{225}$Ac. This technique is compatible with the online accumulation of a laser-cooled atomic francium sample for a series of planned parity non-conservation measurements at TRIUMF. We obtain a 34% release efficiency for $^{221}$Fr from the recoil source based on particle detector measurements. We find that laser cooling operation with the source is $8^{+10}_{-5}$ times less efficient than from a mass-separated ion beam of $^{221}$Fr in the current geometry. While the flux of this source is two to three orders of magnitude lower than typical francium beams from ISOL facilities, the source provides a longer-term supply of francium for offline studies.

Commissioning of the Francium Trapping Facility at TRIUMF

M. Tandecki [1], J. Zhang [2], R. Collister [3], S. Aubin [4], J. A. Behr [1], E. Gomez [5], G. Gwinner [3], L. A. Orozco [2], M. R. Pearson [1]

Abstract

We report on the successful commissioning of the Francium Trapping Facility at TRIUMF. Large laser-cooled samples of francium are produced from a francium ion beam delivered by the ISAC radioactive ion beam facility. The ion beam is neutralized on an yttrium foil, which is subsequently heated to transfer the atoms into the magneto-optical trapping region. We have successfully trapped $^{207}$Fr, $^{209}$Fr and $^{221}$Fr, with a maximum of $2.5 \times 10^5$ $^{209}$Fr atoms. The neutral cold atoms will be used in studies of the weak interaction through measurements of atomic parity non-conservation.

Highly charged ions in Penning traps, a new tool for resolving low lying isomeric states

A. T. Gallant, M. Brodeur [1,2,3], T. Brunner [1,4], U. Chowdhury [1,5], S. Ettenauer [1,2,6,7], V. V. Simon, E. Mané, M. C. Simon, C. Andreoiu [8], P. Delheij [1], G. Gwinner [5], M. R. Pearson [1], R. Ringle [3], J. Dilling [1,2]

Abstract

The use of highly charged ions increases the precision and resolving power, in particular for short-lived species produced at on-line radio-isotope beam facilities, achievable with Penning trap mass spectrometers. This increase in resolving power provides a new and unique access to resolving low-lying long-lived ($T_{1/2} > 50$ ms) nuclear isomers. Recently, the $111.19(22)$ keV (determined from $γ$-ray spectroscopy) isomeric state in $^{78}$Rb has been resolved from the ground state, in a charge state of $q=8+$ with the TITAN Penning trap at the TRIUMF-ISAC facility. The excitation energy of the isomer was measured to be $108.7(6.4)$ keV above the ground state. The extracted masses for both the ground and isomeric states, and their difference, agree with the AME2003 and Nuclear Data Sheet values. This proof of principle measurement demonstrates the feasibility of using Penning trap mass spectrometers coupled to charge breeders to study nuclear isomers and opens a new route for isomer searches.

First Use of High Charge States for Mass Measurements of Short-lived Nuclides in a Penning Trap

S. Ettenauer [1,2], M. C. Simon [1], A. T. Gallant [1,2], T. Brunner [1,3], U. Chowdhury [1,4], V. V. Simon [1,5,6], M. Brodeur [1,2,7], A. Chaudhuri [1], E. Mané, C. Andreoiu [8], G. Audi [9,5], J. R. Crespo López-Urrutia, P. Delheij [1], G. Gwinner [4], A. Lapierre [1,7], D. Lunney [1,9], M. R. Pearson [1], R. Ringle [7], J. Ullrich [5], J. Dilling [1,2]

Abstract

Penning trap mass measurements of short-lived nuclides have been performed for the first time with highly-charged ions (HCI), using the TITAN facility at TRIUMF. Compared to singly-charged ions, this provides an improvement in experimental precision that scales with the charge state q. Neutron-deficient Rb-isotopes have been charge bred in an electron beam ion trap to q = 8 - 12+ prior to injection into the Penning trap. In combination with the Ramsey excitation scheme, this unique setup creating low energy, highly-charged ions at a radioactive beam facility opens the door to unrivalled precision with gains of 1-2 orders of magnitude. The method is particularly suited for short-lived nuclides such as the superallowed β emitter 74Rb (T1/2 = 65 ms). The determination of its atomic mass and an improved QEC-value are presented.

TITAN's Digital RFQ Ion Beam Cooler and Buncher, Operation and Performance

T. Brunner [1], M. J. Smith, M. Brodeur [1], S. Ettenauer [1], A. T. Gallant, V. V. Simon, A. Chaudhuri A. Lapierre, E. Mané, R. Ringle, M. C. Simon, J. A. Vaz, P. Delheij, M. Good, M. R. Pearson, J. Dilling [2]

Abstract

We present a description of the Radio Frequency Quadrupole (RFQ) ion trap built as part of the TITAN facility. It consists of a gas-filled, segmented, linear Paul trap and is the first stage of the TITAN setup with the purpose of cooling and bunching radioactive ion beams delivered from ISAC-TRIUMF. This is the first such device to be driven digitally, i.e., using a high voltage ($V_{pp} = \rm{400 \, V}$), wide bandwidth ($0.2 < f < 1.2 \, \rm{MHz}$) square-wave as compared to the typical sinusoidal wave form. Results from the commissioning of the device as well as systematic studies with stable and radioactive ions are presented including efficiency measurements with stable $^{133}$Cs and radioactive $^{124, 126}$Cs. A novel and unique mode of operation of this device is also demonstrated where the cooled ion bunches are extracted in reverse mode, i.e., in the same direction as previously injected.