M. Good

Improvements to TITAN's Mass Measurement and Decay Spectroscopy Capabilities

D. Lascar, A. A. Kwiatkowski, M. Alanssari, U. Chowdhury, J. Even, A. Finlay, A. T. Gallant, M. Good, R. Klawitter, B. Kootte, T. Li K. G. Leach, A. Lennarz, E. Leistenschneider, A. J. Mayer, B. E. Schultz, R. Schupp [1], D. A. Short, C. Andreoiu [1], J. Dilling [1], G. Gwinner [1]

Abstract

The study of nuclei farther from the valley of $β$-stability goes hand-in-hand with shorter-lived nuclei produced in smaller abundances than their more stable counterparts. The measurement, to high precision, of nuclear masses therefore requires innovations in technique in order to keep up. TRIUMF's Ion Trap for Atomic and Nuclear science (TITAN) facility deploys three ion traps, with a fourth in the commissioning phase, to perform and support Penning trap mass spectrometry and in-trap decay spectroscopy on some of the shortest-lived nuclei ever studied. We report on recent advances and updates to the TITAN facility since the 2012 EMIS Conference. TITAN's charge breeding capabilities have been improved and in-trap decay spectroscopy can be performed in TITAN's electron beam ion trap (EBIT). Higher charge states can improve the precision of mass measurements, reduce the beam-time requirements for a given measurement, improve beam purity and opens the door to access, via in-trap decay and recapture, isotopes not available from the ISOL method. This was recently demonstrated during TITAN's mass measurement of $^{30}$Al. The EBIT's decay spectroscopy setup was commissioned with a successful branching ratio and half-life measurement of $^{124}$Cs. Charge breeding in the EBIT increases the energy spread of the ion bunch sent to the Penning trap for mass measurement so a new Cooler Penning Trap (CPET), which aims to cool highly charge ions with an electron plasma, is undergoing online commissioning. Already, CPET has demonstrated the trapping and self-cooling of a room-temperature electron plasma which was stored for several minutes. A new detector has been installed inside the CPET magnetic field which will allow for in-magnet charged particle detection.

Verifying the accuracy of the TITAN Penning-trap mass spectrometer

M. Brodeur [1,2], V. L. Ryjkov, T. Brunner [1,3], S. Ettenauer [1,2], A. T. Gallant [1,2,4,5], V. V. Simon, M. J. Smith, A. Lapierre [1], R. Ringle [1], P. Delheij [1], M. Good [1], D. Lunney [6], J. Dilling [1,2]

Abstract

TITAN (TRIUMF's Ion Traps for Atomic and Nuclear science) is an online facility designed to carry out high-precision mass measurements on singly and highly charged radioactive ions. The TITAN Penning trap has been built and optimized in order to perform such measurements with an accuracy in the sub ppb-range. A detailed characterization of the TITAN Penning trap is presented and a new compensation method is derived and demonstrated, verifying the performance in the range of sub-ppb.

TITAN's Digital RFQ Ion Beam Cooler and Buncher, Operation and Performance

T. Brunner [1], M. J. Smith, M. Brodeur [1], S. Ettenauer [1], A. T. Gallant, V. V. Simon, A. Chaudhuri A. Lapierre, E. Mané, R. Ringle, M. C. Simon, J. A. Vaz, P. Delheij, M. Good, M. R. Pearson, J. Dilling [2]

Abstract

We present a description of the Radio Frequency Quadrupole (RFQ) ion trap built as part of the TITAN facility. It consists of a gas-filled, segmented, linear Paul trap and is the first stage of the TITAN setup with the purpose of cooling and bunching radioactive ion beams delivered from ISAC-TRIUMF. This is the first such device to be driven digitally, i.e., using a high voltage ($V_{pp} = \rm{400 \, V}$), wide bandwidth ($0.2 < f < 1.2 \, \rm{MHz}$) square-wave as compared to the typical sinusoidal wave form. Results from the commissioning of the device as well as systematic studies with stable and radioactive ions are presented including efficiency measurements with stable $^{133}$Cs and radioactive $^{124, 126}$Cs. A novel and unique mode of operation of this device is also demonstrated where the cooled ion bunches are extracted in reverse mode, i.e., in the same direction as previously injected.