G. Audi

First Use of High Charge States for Mass Measurements of Short-lived Nuclides in a Penning Trap

S. Ettenauer [1,2], M. C. Simon [1], A. T. Gallant [1,2], T. Brunner [1,3], U. Chowdhury [1,4], V. V. Simon [1,5,6], M. Brodeur [1,2,7], A. Chaudhuri [1], E. Mané, C. Andreoiu [8], G. Audi [9,5], J. R. Crespo López-Urrutia, P. Delheij [1], G. Gwinner [4], A. Lapierre [1,7], D. Lunney [1,9], M. R. Pearson [1], R. Ringle [7], J. Ullrich [5], J. Dilling [1,2]

Abstract

Penning trap mass measurements of short-lived nuclides have been performed for the first time with highly-charged ions (HCI), using the TITAN facility at TRIUMF. Compared to singly-charged ions, this provides an improvement in experimental precision that scales with the charge state q. Neutron-deficient Rb-isotopes have been charge bred in an electron beam ion trap to q = 8 - 12+ prior to injection into the Penning trap. In combination with the Ramsey excitation scheme, this unique setup creating low energy, highly-charged ions at a radioactive beam facility opens the door to unrivalled precision with gains of 1-2 orders of magnitude. The method is particularly suited for short-lived nuclides such as the superallowed β emitter 74Rb (T1/2 = 65 ms). The determination of its atomic mass and an improved QEC-value are presented.

Time-separated oscillatory fields for high-precision mass measurements on short-lived Al and Ca nuclides

S. George [1,2], G. Audi [3], B. Blank [4], K. Blaum [1,2,5], M. Breitenfeldt [6], U. Hager [7], F. Herfurth [1], A. Herlert [8], A. Kellerbauer [5], H. -J. Kluge [1,9], M. Kretzschmar [2], D. Lunney [3], R. Savreux [1], S. Schwarz [10], L. Schweikhard [6], C. Yazidjian [1]

Abstract

High-precision Penning trap mass measurements on the stable nuclide 27Al as well as on the short-lived radionuclides 26Al and 38,39Ca have been performed by use of radiofrequency excitation with time-separated oscillatory fields, i.e. Ramsey's method, as recently introduced for the excitation of the ion motion in a Penning trap, was applied. A comparison with the conventional method of a single continuous excitation demonstrates its advantage of up to ten times shorter measurements. The new mass values of 26,27Al clarify conflicting data in this specific mass region. In addition, the resulting mass values of the superallowed beta-emitter 38Ca as well as of the groundstate of the beta-emitter 26Al m confirm previous measurements and corresponding theoretical corrections of the ft-values.