A. Cannon

Precision Mass Measurements of \textsuperscript{130}Te, \textsuperscript{130}Sn, and Their Impact on Models for R-Process Nucleosynthesis

A. Cannon, W. S. Porter, A. A. Valverde, D. P. Burdette, A. M. Houff, B. Liu, A. Mitra, G. E. Morgan, C. Quick [1], D. Ray [1], L. Varriano [1], M. Brodeur [1], J. A. Clark, G. Savard [1], G. J. Mathews

Abstract

The astrophysical rapid neutron capture nucleosynthesis process (r-process) remains an active area of research due to the fact that it occurs in extreme conditions and involves reactions with exotic nuclei that are difficult to study experimentally. For the first time using the Phase-Imaging Ion Cyclotron Resonance (PI-ICR) technique, we measured the mass excesses of \textsuperscript{130}Te, \textsuperscript{130}Sn, and \textsuperscript{130}Sn\textsuperscript{m} with the Canadian Penning Trap (CPT). Our results show good agreement with previous Penning trap values obtained using the Time-of-Flight Ion Cyclotron Resonance (TOF-ICR) and the Fourier Transform Ion Cyclotron Resonance (FT-ICR) techniques, while being twice as precise for \textsuperscript{130}Sn. These new mass excesses were added to a SkyNet network calculation to determine their impact on r-process abundances and to find the best astrophysical conditions to reproduce the Solar System r-process abundance pattern. Finally, by treating lighter and heavier elements separately, we assess the relative frequency of events producing elements in a cold versus a hot r-process scenario.

Off-line Commissioning of the St. Benedict Radiofrequency Quadrupole Cooler-Buncher

D. P. Burdette, R. Zite, M. Brodeur, A. A. Valverde, O. Bruce, R. Bualuan, A. Cannon, J. A. Clark, C. Davis, T. Florenzo, A. T. Gallant, J. Harkin, A. M. Houff, J. Li, B. Liu, J. Long, P. D. O'Malley, W. S. Porter, C. Quick [1], R. Ringle [1], F. Rivero [1], G. Savard [1], M. A. Yeck

Abstract

The St. Benedict ion trapping system, which aims to measure the $β-ν$ angular correlation parameter in superallowed-mixed mirror transitions, is under construction at the University of Notre Dame. These measurements will provide much-needed data to improve the accuracy of the $V_{ud}$ element of the CKM matrix. One of the major components of this system is the radio frequency quadrupole cooler-buncher, which is necessary to create low-emittance ion bunches for injection into the measurement Paul trap. The off-line commissioning of the cooler-buncher, using a potassium ion source, determined that the device could produce cooled ion bunches characterized by a 50-ns full-width-half-maximum time width. The commissioning results also determined the trapping efficiency to be 93(1)$\%$ and the trapping half-life to be 20.0(5) s.

Astrophysical significance of the isomer $^{119m}$Ag demonstrated through direct mass measurement

F. Rivero [1], M. Brodeur [1,2], J. A. Clark, B. Liu [1,2,3,4], G. W. Misch, M. R. Mumpower, W. S. Porter, D. Ray [5,2], G. Savard [2,6,3,5], T. M. Sprouse, A. A. Valverde, D. P. Burdette, A. Cannon [7,8,1], A. T. Gallant, A. M. Houff, K. Kolos [8,2], F. G. Kondev, R. Orford [9], C. Quick [1,5], K. S. Sharma, L. Varriano [10]

Abstract

The abundance of elements heavier than iron produced via the astrophysical rapid-neutron capture process depends sensitively on the atomic mass of the involved nuclei as well as the behavior of a few special types of nuclear isomers called astromers. High-precision mass measurements of $^{119}$Cd, $^{119}$Ag and their respective isomeric states have been performed with the Phase Imaging-Ion Cyclotron Resonance (PI-ICR) method with a precision of $δm/m \approx 10^{-8}$ using the Canadian Penning Trap (CPT). The ground state mass excess, as well as the excitation energy, agrees with recent Penning Trap measurements from JYFLTRAP. Network calculations using these new measurements revealed that, contrary to previous expectations, $^{119m}$Ag behaves as an astromer which significantly affects the population of $^{119}$Ag.