G. Bollen

High-precision Penning trap mass measurements of neutron-rich chlorine isotopes at the N=28 shell closure

H. Erington [1,2], G. Bollen [1,2], G. Dykstra [3], A. Hamaker [1,2], C. M. Ireland [1,2], C. R. Nicoloff [1,2], D. Puentes [1,2], R. Ringle [1,2], S. Schwarz [1], C. S. Sumithrarachchi [1], A. A. Valverde [4,5], I. T. Yandow [1,2]

Abstract

Although it is known that the $N=28$ spherical shell closure erodes, the strength of the closure with decreasing proton number $Z<20$ is an open question in nuclear structure. In this region of interest, direct high-precision mass measurements of neutron-rich $^{43-45}$Cl isotopes were performed at the Low Energy Beam and Ion Trap (LEBIT) when coupled to the National Superconducting Cyclotron Lab. The resulting mass excesses (MEs) are ME($^{43}$Cl) = -24114.4(1.7) keV, ME($^{44}$Cl) = -20450.8(10.6) keV, and ME($^{45}$Cl) = -18240.1(3.7) keV, and improve the uncertainty of these masses by up to a factor of ~40 compared to the previous values reported in the 2020 Atomic Mass Evaluation. Comparison to $\textit{ab initio}$ calculations using the Valence-Space In-Medium Similarity Renormalization Group (VS-IMSRG) shows good agreement up to and including the closure.

Precision Mass Measurements of Neutron-Rich Co Isotopes Beyond N=40

C. Izzo [1,2], G. Bollen [1,3], M. Brodeur [4], M. Eibach [2,5], K. Gulyuz [2], J. D. Holt [6], J. M. Kelly [4], M. Redshaw [2,7,8], R. Ringle [2], R. Sandler [1,2,7,8], S. Schwarz [2], S. R. Stroberg [6], C. S. Sumithrarachchi [2], A. A. Valverde [1,2], A. C. C. Villari [3]

Abstract

The region near Z=28, N=40 is a subject of great interest for nuclear structure studies due to spectroscopic signatures in $^{68}$Ni suggesting a subshell closure at N=40. Trends in nuclear masses and their derivatives provide a complementary approach to shell structure investigations via separation energies. Penning trap mass spectrometry has provided precise measurements for a number of nuclei in this region, however a complete picture of the mass surfaces has so far been limited by the large uncertainty remaining for nuclei with N > 40 along the iron and cobalt chains. Here we present the first Penning trap measurements of $^{68,69}$Co, performed at the Low-Energy Beam and Ion Trap facility at the National Superconducting Cyclotron Laboratory. In addition, we perform ab initio calculations of ground state and two-neutron separation energies of cobalt isotopes with the valence-space in-medium similarity renormalization group approach based on a particular set of two- and three-nucleon forces which predict saturation in infinite matter. We discuss the importance of these measurements and calculations for understanding the evolution of nuclear structure near $^{68}$Ni.

Electric and magnetic field optimization procedure for Penning trap mass spectrometers

D. Beck, K. Blaum, G. Bollen, P. Delahaye, S. George, C. Guenaut, F. Herfurth, A. Herlert, D. Lunney, L. Schweikhard [1], C. Yazidjian [1]

Abstract

Significant systematic errors in high-precision Penning trap mass spectrometry can result from electric and magnetic field imperfections. An experimental procedure to minimize these uncertainties is presented for the on-line Penning trap mass spectrometer ISOLTRAP, located at ISOLDE/CERN. The deviations from the ideal magnetic and electric fields are probed by measuring the cyclotron frequency and the reduced cyclotron frequency, respectively, of stored ions as a function of the time between the ejection of ions from the preparation trap and their capture in the precision trap, which influences the energy of their axial motion. The correction parameters are adjusted to minimize the frequency shifts.

A linear radiofrequency ion trap for accumulation, bunching, and emittance improvement of radioactive ion beams

F. Herfurth, J. Dilling, A. Kellerbauer, G. Bollen, S. Henry, H. -J. Kluge, E. Lamour, D. Lunney, R. B. Moore, C. Scheidenberger, S. Schwarz, G. Sikler, J. Szerypo [1]

Abstract

An ion beam cooler and buncher has been developed for the manipulation of radioactive ion beams. The gas-filled linear radiofrequency ion trap system is installed at the Penning trap mass spectrometer ISOLTRAP at ISOLDE/CERN. Its purpose is to accumulate the 60-keV continuous ISOLDE ion beam with high efficiency and to convert it into low-energy low-emittance ion pulses. The efficiency was found to exceed 10% in agreement with simulations. A more than 10-fold reduction of the ISOLDE beam emittance can be achieved. The system has been used successfully for first on-line experiments. Its principle, setup and performance will be discussed.