S. George

PENTATRAP: A novel cryogenic multi-Penning trap experiment for high-precision mass measurements on highly charged ions

J. Repp [1,2,3], Ch. Böhm, J. R. Crespo López-Urrutia, A. Dörr, S. Eliseev [1], S. George [1], M. Goncharov [1,2,3,4], Yu. N. Novikov, C. Roux [1,2], S. Sturm [1,5], S. Ulmer [1,2,5], K. Blaum [1,2]

Abstract

The novel five-Penning trap mass spectrometer PENTATRAP is developed at the Max-Planck-Institut für Kernphysik (MPIK), Heidelberg. Ions of interest are long-lived highly charged nuclides up to bare uranium. PENTATRAP aims for an accuracy of a few parts in 10^12 for mass ratios of mass doublets. A physics program for PENTATRAP includes Q-values measurements of β-transitions relevant for neutrino physics, stringent tests of quantum electrodynamics in the regime of extreme electric fields, and a test of special relativity. Main features of PENTATRAP are an access to a source of highly charged ions, a multi-trap configuration, simultaneous measurements of frequencies, a continuous precise monitoring of magnetic field fluctuations, a fast exchange between different ions, and a highly sensitive cryogenic non-destructive detection system. This paper gives a motivation for the new mass spectrometer PENTATRAP, presents its experimental setup, and describes the present status.

The trap design of PENTATRAP

C. Roux [1,2,3], Ch. Böhm, A. Dörr, S. Eliseev [1], S. George [1,2], Yu. Novikov [3,4], J. Repp [1,2], S. Sturm [1,5], S. Ulmer [1,2,5], K. Blaum [1,2]

Abstract

A novel Penning trap tower consisting of five compensated cylindrical Penning traps is developed for the PENTATRAP mass spectrometer at the Max-Planck-Institut für Kernphysik in Heidelberg, Germany. An analytical expression for the electrostatic potential inside the trap tower is derived to calculate standard Penning trap properties like the compensation of anharmonicities and an orthogonal geometry of the trap electrodes. Since the PENTATRAP project described in the preceding article aims for ultra high-precision mass-ratio measurements of highly charged ions up to uranium, systematic effects for highly charged ions inside the trap tower are considered for the design process as well. Finally, a limit due to remaining anharmonic shifts at large amplitudes is estimated for the resulting geometry, which is important for phase-sensitive measurements of the reduced cyclotron frequency of the ions.

Position-sensitive ion detection in precision Penning trap mass spectrometry

G. Eitel, M. Block, A. Czasch, M. Dworschak, S. George, O. Jagutzki, J. Ketelaer, J. Ketter, Sz. Nagy, D. Rodriguez, C. Smorra [1], K. Blaum [1]

Abstract

A commercial, position-sensitive ion detector was used for the first time for the time-of-flight ion-cyclotron resonance detection technique in Penning trap mass spectrometry. In this work, the characteristics of the detector and its implementation in a Penning trap mass spectrometer will be presented. In addition, simulations and experimental studies concerning the observation of ions ejected from a Penning trap are described. This will allow for a precise monitoring of the state of ion motion in the trap.

Electric and magnetic field optimization procedure for Penning trap mass spectrometers

D. Beck, K. Blaum, G. Bollen, P. Delahaye, S. George, C. Guenaut, F. Herfurth, A. Herlert, D. Lunney, L. Schweikhard [1], C. Yazidjian [1]

Abstract

Significant systematic errors in high-precision Penning trap mass spectrometry can result from electric and magnetic field imperfections. An experimental procedure to minimize these uncertainties is presented for the on-line Penning trap mass spectrometer ISOLTRAP, located at ISOLDE/CERN. The deviations from the ideal magnetic and electric fields are probed by measuring the cyclotron frequency and the reduced cyclotron frequency, respectively, of stored ions as a function of the time between the ejection of ions from the preparation trap and their capture in the precision trap, which influences the energy of their axial motion. The correction parameters are adjusted to minimize the frequency shifts.

TRIGA-SPEC: A setup for mass spectrometry and laser spectroscopy at the research reactor TRIGA Mainz

J. Ketelaer, J. Krämer, D. Beck, K. Blaum, M. Block, K. Eberhardt, G. Eitel, R. Ferrer, C. Geppert, S. George, F. Herfurth, J. Ketter, Sz. Nagy, D. Neidherr, R. Neugart [1], W. Nörtershäuser, J. Repp [1], C. Smorra [1], N. Trautmann [1], C. Weber [1]

Abstract

The research reactor TRIGA Mainz is an ideal facility to provide neutron-rich nuclides with production rates sufficiently large for mass spectrometric and laser spectroscopic studies. Within the TRIGA-SPEC project, a Penning trap as well as a beam line for collinear laser spectroscopy are being installed. Several new developments will ensure high sensitivity of the trap setup enabling mass measurements even on a single ion. Besides neutron-rich fission products produced in the reactor, also heavy nuclides such as 235-U or 252-Cf can be investigated for the first time with an off-line ion source. The data provided by the mass measurements will be of interest for astrophysical calculations on the rapid neutron-capture process as well as for tests of mass models in the heavy-mass region. The laser spectroscopic measurements will yield model-independent information on nuclear ground-state properties such as nuclear moments and charge radii of neutron-rich nuclei of refractory elements far from stability. This publication describes the experimental setup as well as its present status.

Time-separated oscillatory fields for high-precision mass measurements on short-lived Al and Ca nuclides

S. George [1,2], G. Audi [3], B. Blank [4], K. Blaum [1,2,5], M. Breitenfeldt [6], U. Hager [7], F. Herfurth [1], A. Herlert [8], A. Kellerbauer [5], H. -J. Kluge [1,9], M. Kretzschmar [2], D. Lunney [3], R. Savreux [1], S. Schwarz [10], L. Schweikhard [6], C. Yazidjian [1]

Abstract

High-precision Penning trap mass measurements on the stable nuclide 27Al as well as on the short-lived radionuclides 26Al and 38,39Ca have been performed by use of radiofrequency excitation with time-separated oscillatory fields, i.e. Ramsey's method, as recently introduced for the excitation of the ion motion in a Penning trap, was applied. A comparison with the conventional method of a single continuous excitation demonstrates its advantage of up to ten times shorter measurements. The new mass values of 26,27Al clarify conflicting data in this specific mass region. In addition, the resulting mass values of the superallowed beta-emitter 38Ca as well as of the groundstate of the beta-emitter 26Al m confirm previous measurements and corresponding theoretical corrections of the ft-values.

The Ramsey method in high-precision mass spectrometry with Penning traps: Experimental results

S. George [1,2], K. Blaum [1,2], F. Herfurth [1], A. Herlert [3], M. Kretzschmar [2], S. Nagy [2], S. Schwarz [4], L. Schweikhard [5], C. Yazidjian [1]

Abstract

The highest precision in direct mass measurements is obtained with Penning trap mass spectrometry. Most experiments use the interconversion of the magnetron and cyclotron motional modes of the stored ion due to excitation by external radiofrequency-quadrupole fields. In this work a new excitation scheme, Ramsey's method of time-separated oscillatory fields, has been successfully tested. It has been shown to reduce significantly the uncertainty in the determination of the cyclotron frequency and thus of the ion mass of interest. The theoretical description of the ion motion excited with Ramsey's method in a Penning trap and subsequently the calculation of the resonance line shapes for different excitation times, pulse structures, and detunings of the quadrupole field has been carried out in a quantum mechanical framework and is discussed in detail in the preceding article in this journal by M. Kretzschmar. Here, the new excitation technique has been applied with the ISOLTRAP mass spectrometer at ISOLDE/CERN for mass measurements on stable as well as short-lived nuclides. The experimental resonances are in agreement with the theoretical predictions and a precision gain close to a factor of four was achieved compared to the use of the conventional excitation technique.

Separated Oscillatory Fields for High-Precision Penning Trap Mass Spectrometry

S. George [1,2], S. Baruah [3], B. Blank [4], K. Blaum [1,2], M. Breitenfeldt [3], U. Hager [5], F. Herfurth [1], A. Herlert [6], A. Kellerbauer [7], H. J. Kluge [1,8], M. Kretzschmar [2], D. Lunney [9], R. Savreux [1], S. Schwarz [10], L. Schweikhard [3], C. Yazidjian [1]

Abstract

Ramsey's method of separated oscillatory fields is applied to the excitation of the cyclotron motion of short-lived ions in a Penning trap to improve the precision of their measured mass. The theoretical description of the extracted ion-cyclotron-resonance line shape is derived out and its correctness demonstrated experimentally by measuring the mass of the short-lived $^{38}$Ca nuclide with an uncertainty of $1.6\cdot 10^{-8}$ using the ISOLTRAP Penning trap mass spectrometer at CERN. The mass value of the superallowed beta-emitter $^{38}$Ca is an important contribution for testing the conserved-vector-current hypothesis of the electroweak interaction. It is shown that the Ramsey method applied to mass measurements yields a statistical uncertainty similar to that obtained by the conventional technique ten times faster.