L. Schweikhard

Mass spectrometry of $^{75}$Zn ground and isomeric states from in-trap decay of $^{75}$Cu

M. Müller, N. A. Althubiti [2,3], D. Atanasov [1], K. Blaum [1], R. B. Cakirli [1], T. E. Cocolios [4], F. Herfurth [5], S. Kreim [1], D. Lunney [6], V. Manea [1,7], N. Minkov [1,8], D. Neidherr [5], M. Rosenbusch [9], L. Schweikhard [9], A. Welker [7,10], F. Wienholtz [7,9], R. N. Wolf [1]

Abstract

We report on high-precision mass measurements of the ground and first isomeric state of $^{75}$Zn, performed using the time-of-flight ion-cyclotron-resonance technique at the ISOLTRAP Penning-trap mass spectrometer at ISOLDE/CERN. The isomeric state was produced using in-trap decay of $^{75}$Cu. This marks the first direct investigation of the isomeric state of $^{75}$Zn via mass spectrometry. The isomer was observed at an excitation energy of 123.7(20) keV, in 2$\,σ$ agreement with the value previously determined through decay spectroscopy. In addition, our measurements correct a misassignment of the ground-state mass excess based on a previous measurement by Baruah et al., revising the value to -62681.0(21) keV. To further investigate the earlier discrepancy, we explored the spin-parity assignments of the ground and isomeric states in $^{75}$Zn using Skyrme Hartree-Fock plus Bardeen-Cooper-Schrieffer theoretical calculations, given the absence of definitive experimental data. In light of the laser spectroscopy results from Wraith et al., our results add strong evidence for a spin-1/2 ground state, which would agree with large-scale shell-model predictions as well as explaining disagreements with the Monte Carlo Shell Model.

A multi-reflection time-of-flight mass spectrometer for the offline ion source of the PUMA experiment

M. Schlaich, J. Fischer, P. Fischer, C. Klink, A. Obertelli, A. Schmidt, L. Schweikhard [1], F. Wienholtz [1]

Abstract

The antiProton Unstable Matter Annihilation experiment (PUMA) at CERN aims at investigating the nucleon composition in the matter density tail of radioactive as well as stable isotopes by use of low-energy antiproton-nucleon annihilation processes. For this purpose, antiprotons provided by the Extra Low ENergy Antiproton (ELENA) facility will be trapped together with the ions of interest. While exotic ions will be obtained by the Isotope mass Separator On-Line DEvice (ISOLDE), stable ions will be delivered from an offline ion source setup designed for this purpose. This allows the proposed technique to be applied to a variety of stable nuclei and for reference measurements. For beam purification, the ion source setup includes a multi-reflection time-of-flight mass spectrometer (MR-ToF MS). Supported by SIMION simulations, an earlier MR-ToF MS design has been modified to meet the requirements of PUMA. During commissioning of the new MR-ToF device with Ar$^+$ ions, mass resolving powers in excess of 50,000 have been obtained after 150 revolutions, limited by the chopping of the continuous beam from an electron impact ionisation source.

In-source and in-trap formation of molecular ions in the actinide mass range at CERN-ISOLDE

M. Au, M. Athanasakis-Kaklamanakis, L. Nies, J. Ballof, R. Berger, K. Chrysalidis, P. Fischer, R. Heinke, J. Johnson, U. Köster, D. Leimbach, B. Marsh, M. Mougeot, J. Reilly, E. Reis, M. Schlaich, Ch. Schweiger, L. Schweikhard, S. Stegemann [1], J. Wessolek [1], F. Wienholtz [1], S. G. Wilkins [1], W. Wojtaczka [1], Ch. E. Düllmann, S. Rothe [1]

Abstract

The use of radioactive molecules for fundamental physics research is a developing interdisciplinary field limited dominantly by their scarce availability. In this work, radioactive molecular ion beams containing actinide nuclei extracted from uranium carbide targets are produced via the Isotope Separation On-Line technique at the CERN-ISOLDE facility. Two methods of molecular beam production are studied: extraction of molecular ion beams from the ion source, and formation of molecular ions from the mass-separated ion beam in a gas-filled radio-frequency quadrupole ion trap. Ion currents of U$^+$, UO$_{1-3}^+$, UC$_{1-3}^+$, UF$_{1-4}^+$, UF$_{1,2}$O$_{1,2}^+$ are reported. Metastable tantalum and uranium fluoride molecular ions are identified. Formation of UO$_{1-3}^+$, U(OH)$_{1-3}^+$, UC$_{1-3}^+$, UF$_{1,2}$O$_{1,2}^+$ from mass-separated beams of U$^+$, UF$_{1,2}^+$ with residual gas is observed in the ion trap. The effect of trapping time on molecular formation is presented.

Charge radii, moments and masses of mercury isotopes across the N = 126 shell closure

T. Day Goodacre [1,2,3,4,5], A. V. Afanasjev, A. E. Barzakh, L. Nies [2,6], B. A. Marsh, S. Sels [2,7,4], U. C. Perera, P. Ring [8], F. Wienholtz [2,6,9,10], A. N. Andreyev, P. Van Duppen [7,1,11], N. A. Althubiti, B. Andel [7,12], D. Atanasov [13,3], R. S. Augusto, J. Billowes [1], K. Blaum [13,1,7,9,5,2,14,15], T. E. Cocolios, J. G. Cubiss, G. J. Farooq-Smith, D. V. Fedorov, V. N. Fedosseev, K. T. Flanagan, L. P. Gaffney, L. Ghys [7,16], A. Gottberg [3,17], M. Huyse [7], S. Kreim [13,2], P. Kunz [3,18], D. Lunney [19,1,2], K. M. Lynch, V. Manea [13], Y. Martinez Palenzuela [7,2,5], T. M. Medonca, P. L. Molkanov, M. Mougeot [2], J. P. Ramos, M. Rosenbusch [6,2,20], R. E. Rossel, S. Rothe [2], L. Schweikhard [6,5], M. D. Seliverstov, P. Spagnoletti [15], C. Van Beveren [7], M. Veinhard [2], E. Verstraelen [7], A. Welker [2,21], K. Wendt [20,13,6], R. N. Wolf, A. Zadvornaya [7], K. Zuber [21]

Abstract

Combining laser spectroscopy in a Versatile Arc Discharge and Laser Ion Source, with Penning-trap mass spectrometry at the CERN-ISOLDE facility, this work reports on mean-square charge radii of neutron-rich mercury isotopes across the $N = 126$ shell closure, the electromagnetic moments of $^{207}$Hg and more precise mass values of $^{206-208}$Hg. The odd-even staggering (OES) of the mean square charge radii and the kink at $N = 126$ are analyzed within the framework of covariant density functional theory (CDFT), with comparisons between different functionals to investigate the dependence of the results on the underlying single-particle structure. The observed features are defined predominantly in the particle-hole channel in CDFT, since both are present in the calculations without pairing. However, the magnitude of the kink is still affected by the occupation of the $1i_{11/2}$ and $2g_{9/2}$ orbitals with a dependence on the relative energies as well as pairing.

Direct determination of the atomic mass difference of Re187 and Os187 for neutrino physics and cosmochronology

D. A. Nesterenko, S. Eliseev [1], K. Blaum [1], M. Block [3], S. Chenmarev [1,4], A. Doerr, C. Droese [5,6,1,4], P. E. Filianin, M. Goncharov [1], E. Minaya Ramirez [1,2,4], Yu. N. Novikov, L. Schweikhard [5,3,6], V. V. Simon

Abstract

For the first time a direct determination of the atomic mass difference of 187Re and 187Os has been performed with the Penning-trap mass spectrometer SHIPTRAP applying the novel phase-imaging ion-cyclotron-resonance technique. The obtained value of 2492(30stat)(15sys) eV is in excellent agreement with the Q values determined indirectly with microcalorimetry and thus resolves a long-standing discrepancy with older proportional counter measurements. This is essential for the determination of the neutrino mass from the beta-decay of 187Re as planned in future microcalorimetric measurements. In addition, an accurate mass difference of 187Re and 187Os is also important for the assessment of 187Re for cosmochronology.

Direct Measurement of the Mass Difference of Ho163 and Dy163 Solves the Q-Value Puzzle for the Neutrino Mass Determination

S. Eliseev [1], K. Blaum [1], M. Block [2,3,4], S. Chenmarev [1,5], H. Dorrer [4,6,7,2,3,8], Ch. E. Duellmann, C. Enss [9,1,5], P. E. Filianin, L. Gastaldo [9], M. Goncharov [1,10,2,5,11], U. Koester, F. Lautenschlaeger, Yu. N. Novikov, A. Rischka [1], R. X. Schuessler, L. Schweikhard [12,6,7], A. Tuerler

Abstract

The atomic mass difference of 163Ho and 163Dy has been directly measured with the Penning trap mass spectrometer SHIPTRAP applying the novel phase imaging ion cyclotron resonance technique. Our measurement has solved the long standing problem of large discrepancies in the Q value of the electron capture in 163Ho determined by different techniques. Our measured mass difference shifts the current Q value of 2555(16) eV evaluated in the Atomic Mass Evaluation 2012 [G. Audi et al., Chin. Phys. C 36, 1157 (2012)] by more than 7 sigma to 2833(30stat)(15sys) eV/c2. With the new mass difference it will be possible, e.g., to reach in the first phase of the ECHo experiment a statistical sensitivity to the neutrino mass below 10 eV, which will reduce its present upper limit by more than an order of magnitude.

Electric and magnetic field optimization procedure for Penning trap mass spectrometers

D. Beck, K. Blaum, G. Bollen, P. Delahaye, S. George, C. Guenaut, F. Herfurth, A. Herlert, D. Lunney, L. Schweikhard [1], C. Yazidjian [1]

Abstract

Significant systematic errors in high-precision Penning trap mass spectrometry can result from electric and magnetic field imperfections. An experimental procedure to minimize these uncertainties is presented for the on-line Penning trap mass spectrometer ISOLTRAP, located at ISOLDE/CERN. The deviations from the ideal magnetic and electric fields are probed by measuring the cyclotron frequency and the reduced cyclotron frequency, respectively, of stored ions as a function of the time between the ejection of ions from the preparation trap and their capture in the precision trap, which influences the energy of their axial motion. The correction parameters are adjusted to minimize the frequency shifts.

Time-separated oscillatory fields for high-precision mass measurements on short-lived Al and Ca nuclides

S. George [1,2], G. Audi [3], B. Blank [4], K. Blaum [1,2,5], M. Breitenfeldt [6], U. Hager [7], F. Herfurth [1], A. Herlert [8], A. Kellerbauer [5], H. -J. Kluge [1,9], M. Kretzschmar [2], D. Lunney [3], R. Savreux [1], S. Schwarz [10], L. Schweikhard [6], C. Yazidjian [1]

Abstract

High-precision Penning trap mass measurements on the stable nuclide 27Al as well as on the short-lived radionuclides 26Al and 38,39Ca have been performed by use of radiofrequency excitation with time-separated oscillatory fields, i.e. Ramsey's method, as recently introduced for the excitation of the ion motion in a Penning trap, was applied. A comparison with the conventional method of a single continuous excitation demonstrates its advantage of up to ten times shorter measurements. The new mass values of 26,27Al clarify conflicting data in this specific mass region. In addition, the resulting mass values of the superallowed beta-emitter 38Ca as well as of the groundstate of the beta-emitter 26Al m confirm previous measurements and corresponding theoretical corrections of the ft-values.

The Ramsey method in high-precision mass spectrometry with Penning traps: Experimental results

S. George [1,2], K. Blaum [1,2], F. Herfurth [1], A. Herlert [3], M. Kretzschmar [2], S. Nagy [2], S. Schwarz [4], L. Schweikhard [5], C. Yazidjian [1]

Abstract

The highest precision in direct mass measurements is obtained with Penning trap mass spectrometry. Most experiments use the interconversion of the magnetron and cyclotron motional modes of the stored ion due to excitation by external radiofrequency-quadrupole fields. In this work a new excitation scheme, Ramsey's method of time-separated oscillatory fields, has been successfully tested. It has been shown to reduce significantly the uncertainty in the determination of the cyclotron frequency and thus of the ion mass of interest. The theoretical description of the ion motion excited with Ramsey's method in a Penning trap and subsequently the calculation of the resonance line shapes for different excitation times, pulse structures, and detunings of the quadrupole field has been carried out in a quantum mechanical framework and is discussed in detail in the preceding article in this journal by M. Kretzschmar. Here, the new excitation technique has been applied with the ISOLTRAP mass spectrometer at ISOLDE/CERN for mass measurements on stable as well as short-lived nuclides. The experimental resonances are in agreement with the theoretical predictions and a precision gain close to a factor of four was achieved compared to the use of the conventional excitation technique.

Separated Oscillatory Fields for High-Precision Penning Trap Mass Spectrometry

S. George [1,2], S. Baruah [3], B. Blank [4], K. Blaum [1,2], M. Breitenfeldt [3], U. Hager [5], F. Herfurth [1], A. Herlert [6], A. Kellerbauer [7], H. J. Kluge [1,8], M. Kretzschmar [2], D. Lunney [9], R. Savreux [1], S. Schwarz [10], L. Schweikhard [3], C. Yazidjian [1]

Abstract

Ramsey's method of separated oscillatory fields is applied to the excitation of the cyclotron motion of short-lived ions in a Penning trap to improve the precision of their measured mass. The theoretical description of the extracted ion-cyclotron-resonance line shape is derived out and its correctness demonstrated experimentally by measuring the mass of the short-lived $^{38}$Ca nuclide with an uncertainty of $1.6\cdot 10^{-8}$ using the ISOLTRAP Penning trap mass spectrometer at CERN. The mass value of the superallowed beta-emitter $^{38}$Ca is an important contribution for testing the conserved-vector-current hypothesis of the electroweak interaction. It is shown that the Ramsey method applied to mass measurements yields a statistical uncertainty similar to that obtained by the conventional technique ten times faster.