F. Herfurth

Mass spectrometry of $^{75}$Zn ground and isomeric states from in-trap decay of $^{75}$Cu

M. Müller, N. A. Althubiti [2,3], D. Atanasov [1], K. Blaum [1], R. B. Cakirli [1], T. E. Cocolios [4], F. Herfurth [5], S. Kreim [1], D. Lunney [6], V. Manea [1,7], N. Minkov [1,8], D. Neidherr [5], M. Rosenbusch [9], L. Schweikhard [9], A. Welker [7,10], F. Wienholtz [7,9], R. N. Wolf [1]

Abstract

We report on high-precision mass measurements of the ground and first isomeric state of $^{75}$Zn, performed using the time-of-flight ion-cyclotron-resonance technique at the ISOLTRAP Penning-trap mass spectrometer at ISOLDE/CERN. The isomeric state was produced using in-trap decay of $^{75}$Cu. This marks the first direct investigation of the isomeric state of $^{75}$Zn via mass spectrometry. The isomer was observed at an excitation energy of 123.7(20) keV, in 2$\,σ$ agreement with the value previously determined through decay spectroscopy. In addition, our measurements correct a misassignment of the ground-state mass excess based on a previous measurement by Baruah et al., revising the value to -62681.0(21) keV. To further investigate the earlier discrepancy, we explored the spin-parity assignments of the ground and isomeric states in $^{75}$Zn using Skyrme Hartree-Fock plus Bardeen-Cooper-Schrieffer theoretical calculations, given the absence of definitive experimental data. In light of the laser spectroscopy results from Wraith et al., our results add strong evidence for a spin-1/2 ground state, which would agree with large-scale shell-model predictions as well as explaining disagreements with the Monte Carlo Shell Model.

Electric and magnetic field optimization procedure for Penning trap mass spectrometers

D. Beck, K. Blaum, G. Bollen, P. Delahaye, S. George, C. Guenaut, F. Herfurth, A. Herlert, D. Lunney, L. Schweikhard [1], C. Yazidjian [1]

Abstract

Significant systematic errors in high-precision Penning trap mass spectrometry can result from electric and magnetic field imperfections. An experimental procedure to minimize these uncertainties is presented for the on-line Penning trap mass spectrometer ISOLTRAP, located at ISOLDE/CERN. The deviations from the ideal magnetic and electric fields are probed by measuring the cyclotron frequency and the reduced cyclotron frequency, respectively, of stored ions as a function of the time between the ejection of ions from the preparation trap and their capture in the precision trap, which influences the energy of their axial motion. The correction parameters are adjusted to minimize the frequency shifts.

TRIGA-SPEC: A setup for mass spectrometry and laser spectroscopy at the research reactor TRIGA Mainz

J. Ketelaer, J. Krämer, D. Beck, K. Blaum, M. Block, K. Eberhardt, G. Eitel, R. Ferrer, C. Geppert, S. George, F. Herfurth, J. Ketter, Sz. Nagy, D. Neidherr, R. Neugart [1], W. Nörtershäuser, J. Repp [1], C. Smorra [1], N. Trautmann [1], C. Weber [1]

Abstract

The research reactor TRIGA Mainz is an ideal facility to provide neutron-rich nuclides with production rates sufficiently large for mass spectrometric and laser spectroscopic studies. Within the TRIGA-SPEC project, a Penning trap as well as a beam line for collinear laser spectroscopy are being installed. Several new developments will ensure high sensitivity of the trap setup enabling mass measurements even on a single ion. Besides neutron-rich fission products produced in the reactor, also heavy nuclides such as 235-U or 252-Cf can be investigated for the first time with an off-line ion source. The data provided by the mass measurements will be of interest for astrophysical calculations on the rapid neutron-capture process as well as for tests of mass models in the heavy-mass region. The laser spectroscopic measurements will yield model-independent information on nuclear ground-state properties such as nuclear moments and charge radii of neutron-rich nuclei of refractory elements far from stability. This publication describes the experimental setup as well as its present status.

Time-separated oscillatory fields for high-precision mass measurements on short-lived Al and Ca nuclides

S. George [1,2], G. Audi [3], B. Blank [4], K. Blaum [1,2,5], M. Breitenfeldt [6], U. Hager [7], F. Herfurth [1], A. Herlert [8], A. Kellerbauer [5], H. -J. Kluge [1,9], M. Kretzschmar [2], D. Lunney [3], R. Savreux [1], S. Schwarz [10], L. Schweikhard [6], C. Yazidjian [1]

Abstract

High-precision Penning trap mass measurements on the stable nuclide 27Al as well as on the short-lived radionuclides 26Al and 38,39Ca have been performed by use of radiofrequency excitation with time-separated oscillatory fields, i.e. Ramsey's method, as recently introduced for the excitation of the ion motion in a Penning trap, was applied. A comparison with the conventional method of a single continuous excitation demonstrates its advantage of up to ten times shorter measurements. The new mass values of 26,27Al clarify conflicting data in this specific mass region. In addition, the resulting mass values of the superallowed beta-emitter 38Ca as well as of the groundstate of the beta-emitter 26Al m confirm previous measurements and corresponding theoretical corrections of the ft-values.

HITRAP: A facility at GSI for highly charged ions

H. -J. Kluge, T. Beier, K. Blaum, L. Dahl, S. Eliseev, F. Herfurth, B. Hofmann, O. Kester, S. Koszudowski, C. Kozhuharov, G. Maero, W. Noertershaeuser, J. Pfister, W. Quint, U. Ratzinger, A. Schempp, R. Schuch [1,2], T. Stoehlker, R. C. Thompson, M. Vogel [1], G. Vorobjev [1], D. F. A. Winters, G. Werth [1]

Abstract

An overview and status report of the new trapping facility for highly charged ions at the Gesellschaft fuer Schwerionenforschung is presented. The construction of this facility started in 2005 and is expected to be completed in 2008. Once operational, highly charged ions will be loaded from the experimental storage ring ESR into the HITRAP facility, where they are decelerated and cooled. The kinetic energy of the initially fast ions is reduced by more than fourteen orders of magnitude and their thermal energy is cooled to cryogenic temperatures. The cold ions are then delivered to a broad range of atomic physics experiments.

The Ramsey method in high-precision mass spectrometry with Penning traps: Experimental results

S. George [1,2], K. Blaum [1,2], F. Herfurth [1], A. Herlert [3], M. Kretzschmar [2], S. Nagy [2], S. Schwarz [4], L. Schweikhard [5], C. Yazidjian [1]

Abstract

The highest precision in direct mass measurements is obtained with Penning trap mass spectrometry. Most experiments use the interconversion of the magnetron and cyclotron motional modes of the stored ion due to excitation by external radiofrequency-quadrupole fields. In this work a new excitation scheme, Ramsey's method of time-separated oscillatory fields, has been successfully tested. It has been shown to reduce significantly the uncertainty in the determination of the cyclotron frequency and thus of the ion mass of interest. The theoretical description of the ion motion excited with Ramsey's method in a Penning trap and subsequently the calculation of the resonance line shapes for different excitation times, pulse structures, and detunings of the quadrupole field has been carried out in a quantum mechanical framework and is discussed in detail in the preceding article in this journal by M. Kretzschmar. Here, the new excitation technique has been applied with the ISOLTRAP mass spectrometer at ISOLDE/CERN for mass measurements on stable as well as short-lived nuclides. The experimental resonances are in agreement with the theoretical predictions and a precision gain close to a factor of four was achieved compared to the use of the conventional excitation technique.

Separated Oscillatory Fields for High-Precision Penning Trap Mass Spectrometry

S. George [1,2], S. Baruah [3], B. Blank [4], K. Blaum [1,2], M. Breitenfeldt [3], U. Hager [5], F. Herfurth [1], A. Herlert [6], A. Kellerbauer [7], H. J. Kluge [1,8], M. Kretzschmar [2], D. Lunney [9], R. Savreux [1], S. Schwarz [10], L. Schweikhard [3], C. Yazidjian [1]

Abstract

Ramsey's method of separated oscillatory fields is applied to the excitation of the cyclotron motion of short-lived ions in a Penning trap to improve the precision of their measured mass. The theoretical description of the extracted ion-cyclotron-resonance line shape is derived out and its correctness demonstrated experimentally by measuring the mass of the short-lived $^{38}$Ca nuclide with an uncertainty of $1.6\cdot 10^{-8}$ using the ISOLTRAP Penning trap mass spectrometer at CERN. The mass value of the superallowed beta-emitter $^{38}$Ca is an important contribution for testing the conserved-vector-current hypothesis of the electroweak interaction. It is shown that the Ramsey method applied to mass measurements yields a statistical uncertainty similar to that obtained by the conventional technique ten times faster.

A linear radiofrequency ion trap for accumulation, bunching, and emittance improvement of radioactive ion beams

F. Herfurth, J. Dilling, A. Kellerbauer, G. Bollen, S. Henry, H. -J. Kluge, E. Lamour, D. Lunney, R. B. Moore, C. Scheidenberger, S. Schwarz, G. Sikler, J. Szerypo [1]

Abstract

An ion beam cooler and buncher has been developed for the manipulation of radioactive ion beams. The gas-filled linear radiofrequency ion trap system is installed at the Penning trap mass spectrometer ISOLTRAP at ISOLDE/CERN. Its purpose is to accumulate the 60-keV continuous ISOLDE ion beam with high efficiency and to convert it into low-energy low-emittance ion pulses. The efficiency was found to exceed 10% in agreement with simulations. A more than 10-fold reduction of the ISOLDE beam emittance can be achieved. The system has been used successfully for first on-line experiments. Its principle, setup and performance will be discussed.