S. Eliseev

$\text{Direct}~Q\text{-Value Determination of the}~β^-~\text{Decay of} ~^{187}\text{Re}$

P. Filianin [1], C. Lyu [1], M. Door [1], K. Blaum [1,2], W. J. Huang, M. Haverkort [3], P. Indelicato [4,1], C. H. Keitel, K. Kromer [1], D. Lange [1,5,6], Y. N. Novikov, A. Rischka [7,1], R. X. Schüssler, Ch. Schweiger [1], S. Sturm [1], S. Ulmer [8], Z. Harman [1], S. Eliseev [1]

Abstract

The cyclotron frequency ratio of $^{187}\mathrm{Os}^{29+}$ to $^{187}\mathrm{Re}^{29+}$ ions was measured with the Penning-trap mass spectrometer PENTATRAP. The achieved result of $R=1.000\:000\:013\:882(5)$ is to date the most precise such measurement performed on ions. Furthermore, the total binding-energy difference of the 29 missing electrons in Re and Os was calculated by relativistic multiconfiguration methods, yielding the value of $ΔE = 53.5(10)$ eV. Finally, using the achieved results, the mass difference between neutral $^{187}$Re and $^{187}$Os, i.e., the $Q$ value of the $β^-$ decay of $^{187}$Re, is determined to be 2470.9(13) eV.

Direct determination of the atomic mass difference of Re187 and Os187 for neutrino physics and cosmochronology

D. A. Nesterenko, S. Eliseev [1], K. Blaum [1], M. Block [3], S. Chenmarev [1,4], A. Doerr, C. Droese [5,6,1,4], P. E. Filianin, M. Goncharov [1], E. Minaya Ramirez [1,2,4], Yu. N. Novikov, L. Schweikhard [5,3,6], V. V. Simon

Abstract

For the first time a direct determination of the atomic mass difference of 187Re and 187Os has been performed with the Penning-trap mass spectrometer SHIPTRAP applying the novel phase-imaging ion-cyclotron-resonance technique. The obtained value of 2492(30stat)(15sys) eV is in excellent agreement with the Q values determined indirectly with microcalorimetry and thus resolves a long-standing discrepancy with older proportional counter measurements. This is essential for the determination of the neutrino mass from the beta-decay of 187Re as planned in future microcalorimetric measurements. In addition, an accurate mass difference of 187Re and 187Os is also important for the assessment of 187Re for cosmochronology.

Direct Measurement of the Mass Difference of Ho163 and Dy163 Solves the Q-Value Puzzle for the Neutrino Mass Determination

S. Eliseev [1], K. Blaum [1], M. Block [2,3,4], S. Chenmarev [1,5], H. Dorrer [4,6,7,2,3,8], Ch. E. Duellmann, C. Enss [9,1,5], P. E. Filianin, L. Gastaldo [9], M. Goncharov [1,10,2,5,11], U. Koester, F. Lautenschlaeger, Yu. N. Novikov, A. Rischka [1], R. X. Schuessler, L. Schweikhard [12,6,7], A. Tuerler

Abstract

The atomic mass difference of 163Ho and 163Dy has been directly measured with the Penning trap mass spectrometer SHIPTRAP applying the novel phase imaging ion cyclotron resonance technique. Our measurement has solved the long standing problem of large discrepancies in the Q value of the electron capture in 163Ho determined by different techniques. Our measured mass difference shifts the current Q value of 2555(16) eV evaluated in the Atomic Mass Evaluation 2012 [G. Audi et al., Chin. Phys. C 36, 1157 (2012)] by more than 7 sigma to 2833(30stat)(15sys) eV/c2. With the new mass difference it will be possible, e.g., to reach in the first phase of the ECHo experiment a statistical sensitivity to the neutrino mass below 10 eV, which will reduce its present upper limit by more than an order of magnitude.

PENTATRAP: A novel cryogenic multi-Penning trap experiment for high-precision mass measurements on highly charged ions

J. Repp [1,2,3], Ch. Böhm, J. R. Crespo López-Urrutia, A. Dörr, S. Eliseev [1], S. George [1], M. Goncharov [1,2,3,4], Yu. N. Novikov, C. Roux [1,2], S. Sturm [1,5], S. Ulmer [1,2,5], K. Blaum [1,2]

Abstract

The novel five-Penning trap mass spectrometer PENTATRAP is developed at the Max-Planck-Institut für Kernphysik (MPIK), Heidelberg. Ions of interest are long-lived highly charged nuclides up to bare uranium. PENTATRAP aims for an accuracy of a few parts in 10^12 for mass ratios of mass doublets. A physics program for PENTATRAP includes Q-values measurements of β-transitions relevant for neutrino physics, stringent tests of quantum electrodynamics in the regime of extreme electric fields, and a test of special relativity. Main features of PENTATRAP are an access to a source of highly charged ions, a multi-trap configuration, simultaneous measurements of frequencies, a continuous precise monitoring of magnetic field fluctuations, a fast exchange between different ions, and a highly sensitive cryogenic non-destructive detection system. This paper gives a motivation for the new mass spectrometer PENTATRAP, presents its experimental setup, and describes the present status.

The trap design of PENTATRAP

C. Roux [1,2,3], Ch. Böhm, A. Dörr, S. Eliseev [1], S. George [1,2], Yu. Novikov [3,4], J. Repp [1,2], S. Sturm [1,5], S. Ulmer [1,2,5], K. Blaum [1,2]

Abstract

A novel Penning trap tower consisting of five compensated cylindrical Penning traps is developed for the PENTATRAP mass spectrometer at the Max-Planck-Institut für Kernphysik in Heidelberg, Germany. An analytical expression for the electrostatic potential inside the trap tower is derived to calculate standard Penning trap properties like the compensation of anharmonicities and an orthogonal geometry of the trap electrodes. Since the PENTATRAP project described in the preceding article aims for ultra high-precision mass-ratio measurements of highly charged ions up to uranium, systematic effects for highly charged ions inside the trap tower are considered for the design process as well. Finally, a limit due to remaining anharmonic shifts at large amplitudes is estimated for the resulting geometry, which is important for phase-sensitive measurements of the reduced cyclotron frequency of the ions.

Mass Measurements and Implications for the Energy of the High-Spin Isomer in 94Ag

A. Kankainen [1], V. -V. Elomaa [1], L. Batist [2], S. Eliseev [2,3], T. Eronen [1], U. Hager [1], J. Hakala [1], A. Jokinen [1,2,3], I. D. Moore, Yu. N. Novikov, H. Penttilä, A. Popov [2], S. Rahaman [1], S. Rinta-Antila [1], J. Rissanen [1], A. Saastamoinen [1,2], D. M. Seliverstov, T. Sonoda [1], G. Vorobjev [2,3], C. Weber [1], J. Äystö

Abstract

Nuclides in the vicinity of 94Ag have been studied with the Penning trap mass spectrometer JYFLTRAP at the Ion-Guide Separator On-Line. The masses of the two-proton-decay daughter 92Rh and the beta-decay daughter 94Pd of the high-spin isomer in 94Ag have been measured, and the masses of 93Pd and 94Ag have been deduced. When combined with the data from the one-proton or two-proton-decay experiments, the results lead to contradictory mass excess values for the high-spin isomer in 94Ag, -46370(170) or -44970(100) keV, corresponding to excitation energies of 6960(400) or 8360(370) keV, respectively.

HITRAP: A facility at GSI for highly charged ions

H. -J. Kluge, T. Beier, K. Blaum, L. Dahl, S. Eliseev, F. Herfurth, B. Hofmann, O. Kester, S. Koszudowski, C. Kozhuharov, G. Maero, W. Noertershaeuser, J. Pfister, W. Quint, U. Ratzinger, A. Schempp, R. Schuch [1,2], T. Stoehlker, R. C. Thompson, M. Vogel [1], G. Vorobjev [1], D. F. A. Winters, G. Werth [1]

Abstract

An overview and status report of the new trapping facility for highly charged ions at the Gesellschaft fuer Schwerionenforschung is presented. The construction of this facility started in 2005 and is expected to be completed in 2008. Once operational, highly charged ions will be loaded from the experimental storage ring ESR into the HITRAP facility, where they are decelerated and cooled. The kinetic energy of the initially fast ions is reduced by more than fourteen orders of magnitude and their thermal energy is cooled to cryogenic temperatures. The cold ions are then delivered to a broad range of atomic physics experiments.